The characteristics of the X-ray attenuation in electrospun nano(n)- and micro(m)-Bi2O3/polylactic acid (PLA) nanofibre mats with different Bi2O3 loadings were compared as a function of energy using mammography (i.e. tube voltages of 22-49 kV) and X-ray absorption spectroscopy (XAS) (7-20 keV).
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2009
This study examined the response characteristics of three commercially available radiochromic films when exposed to low energy (50 kVp) X-rays. The aim was to evaluate the films for potential use in 2D dosimetry for a low-kV intraoperative radiotherapy (IORT) device known as the 'Intrabeam'. Dose-response relationships were obtained for Gafchromic EBT, XR-RV2, and XR-QA film in water at several distances from the Intrabeam device.