Purpose: This work proposes and implements an experimental methodology, based on polymer gels, for assessing the total geometric uncertainty and characterizing its contributors in Gamma Knife (GK) radiosurgery.
Methods: A treatment plan consisting of 26, 4-mm GK single shot dose distributions, covering an extended region of the Leksell stereotactic space, was prepared and delivered to a polymer gel filled polymethyl methacrylate (PMMA) head phantom (16 cm diameter) used to accurately reproduce every link in the GK treatment chain. The center of each shot served as a "control point" in the assessment of the GK total geometric uncertainty, which depends on (a) the spatial dose delivery uncertainty of the PERFEXION GK unit used in this work, (b) the spatial distortions inherent in MR images commonly used for target delineation, and (c) the geometric uncertainty contributor associated with the image registration procedure performed by the Leksell GammaPlan (LGP) treatment planning system (TPS), in the case that registration is directly based on the apparent fiducial locations depicted in each MR image by the N-shaped rods on the Leksell localization box.
Purpose: To compare TG43-based and Acuros deterministic radiation transport-based calculations of the BrachyVision treatment planning system (TPS) with corresponding Monte Carlo (MC) simulation results in heterogeneous patient geometries, in order to validate Acuros and quantify the accuracy improvement it marks relative to TG43.
Methods: Dosimetric comparisons in the form of isodose lines, percentage dose difference maps, and dose volume histogram results were performed for two voxelized mathematical models resembling an esophageal and a breast brachytherapy patient, as well as an actual breast brachytherapy patient model. The mathematical models were converted to digital imaging and communications in medicine (DICOM) image series for input to the TPS.
Purpose: To measure the output factors (OFs) of the small fields formed by the variable aperture collimator system (iris) of a CyberKnife (CK) robotic radiosurgery system, and determine the k(Q(clin),Q(msr) ) (f(clin),f(msr) ) correction factors for a microchamber and four diode detectors.
Methods: OF measurements were performed using a PTW PinPoint 31014 microchamber, four diode detectors (PTW-60017, -60012, -60008, and the SunNuclear EDGE detector), TLD-100 microcubes, alanine dosimeters, EBT films, and polymer gels for the 5 mm, 7.5 mm, 10 mm, 12.
Purpose: The aim of this work is the dosimetric validation of a deterministic radiation transport based treatment planning system (BRACHYVISION v. 8.8, referred to as TPS in the following) for multiple 192Ir source dwell position brachytherapy applications employing a shielded applicator in homogeneous water geometries.
View Article and Find Full Text PDFPurpose: The aim of this work is to implement a recently proposed dosimetric formalism for nonstandard fields to the calibration and small field output factor measurement of a robotic stereotactic radiosurgery system.
Methods: Reference dosimetry measurements were performed in the nonstandard, 60 mm diameter machine specific reference (msr) field using a Farmer ion chamber, five other cylindrical chambers with cavity lengths ranging from 16.25 down to 2.
Purpose: The aim of this work is to validate a deterministic radiation transport based treatment planning system (TPS) for single 192Ir brachytherapy source dosimetry in homogeneous water geometries.
Methods: TPS results were obtained using the deterministic radiation transport option of a BRACHYVISION v. 8.
Purpose: Water equivalent polymer gel dosimeters and magnetic resonance imaging were employed to measure the output factors of the two smallest treatment fields available in a Gamma Knife model C radiosurgery unit, those formed employing the 4 and 8 mm final collimator helmets.
Methods: Three samples of the VIP normoxic gel formulation were prepared and irradiated so that a single shot of the field whose output factor is to be measured and a single shot of the reference 18 mm field were delivered in each one. Emphasis is given to the development and benchmarking of a refined data processing methodology of reduced uncertainty that fully exploits the 3D dose distributions registered in the dosimeters.
Dose distributions registered in water equivalent, polymer gel dosimeters were used to measure the output factors and off-axis profiles of the radiosurgical photon beams employed for CyberKnife radiosurgery. Corresponding measurements were also performed using a shielded silicon diode commonly employed for CyberKnife commissioning, the PinPoint ion chamber, and Gafchromic EBT films, for reasons of comparison. Polymer gel results of this work for the output factors of the 5, 7.
View Article and Find Full Text PDFAmple literature exists on the dose overestimation by commercially available treatment planning systems in MammoSite applications using high dose rate 192Ir sources for partial breast brachytherapy as monotherapy, due to their inability to predict the dose reduction caused by the radiographic contrast solution in the balloon catheter. In this work Monte Carlo simulation is used to verify the dose rate reduction in a balloon breast applicator which does not vary significantly with distance and it is 1.2% at the prescription distance for the reference simulated geometry of 10% diluted radiographic contrast media and 2.
View Article and Find Full Text PDFAmple literature exists on the dose overestimation by commercially available treatment planning systems in MammoSite applications using high dose rate Ir192 sources for partial breast brachytherapy as monotherapy, due to their inability to predict the dose reduction caused by the radiographic contrast solution in the balloon catheter. In this work Monte Carlo simulation is used to verify the dose rate reduction in a balloon breast applicator which does not vary significantly with distance and it is 1.2% at the prescription distance for the reference simulated geometry of 10% diluted radiographic contrast media and 2.
View Article and Find Full Text PDF169Yb has received a renewed focus lately as an alternative to 192Ir sources for high dose rate (HDR) brachytherapy. Following the results of a recent work by our group which proved 169Yb to be a good candidate for HDR prostate brachytherapy, this work seeks to quantify the radiation shielding requirements for 169Yb HDR brachytherapy applications in comparison to the corresponding requirements for the current 192Ir HDR brachytherapy standard. Monte Carlo simulation (MC) is used to obtain 169Yb and 192Ir broad beam transmission data through lead and concrete.
View Article and Find Full Text PDFIn this work, a polymer gel-magnetic resonance (MR) imaging method is employed for the dosimetric characterization of a new 125I low dose rate seed (IsoSeed model I25.S17). Two vials filled with PABIG gel were prepared in-house and one new seed as well as one commercially available 125I seed of similar dose rate and well-known dosimetric parameters (IsoSeed model I25.
View Article and Find Full Text PDFFor the purpose of evaluating the use of 169Yb for prostate High Dose Rate brachytherapy (HDR), a hypothetical 169Yb source is assumed with the exact same design of the new microSelectron source replacing the 192Ir active core by pure 169Yb metal. Monte Carlo simulation is employed for the full dosimetric characterization of both sources and results are compared following the AAPM TG-43 dosimetric formalism. Monte Carlo calculated dosimetry results are incorporated in a commercially available treatment planning system (SWIFT), which features an inverse treatment planning option based on a multiobjective dose optimization engine.
View Article and Find Full Text PDFThe use of magnetic resonance imaging as a readout method for polymer gel dosimetry commonly involves long imaging sessions, particularly when high spatial resolution is required in all three dimensions, for the investigation of dose distributions with steep dose gradients and stringent dose delivery specifications. In this work, a volume selective turbo spin echo (TSE) pulse sequence is compared to the established Carr-Purcell-Meiboom-Gill (CPMG) multiecho acquisition with regard to providing accurate dosimetric results in significantly reduced imaging times. Polyethylene glycol diacrylate based (PABIG) gels were irradiated and subsequently scanned to obtain R2 relaxation rate measurements, using a CPMG multiecho sequence and a dual echo TSE utilizing an acceleration (turbo) factor of 64.
View Article and Find Full Text PDFMonte Carlo simulation and experimental thermoluminescence dosimetry were utilized for the dosimetric characterization of the new IsoSeed model I25.S17 125I interstitial brachytherapy seed. The new seed design is similar to that of the selectSeed and 6711 seeds, with the exception of its molybdenum marker.
View Article and Find Full Text PDFPhys Med Biol
September 2005
Despite its advantages, the polymer gel-magnetic resonance imaging (MRI) method has not, as yet, been successfully employed in dosimetry of low energy/low dose rate photon-emitting brachytherapy sources such as 125I or 103Pd interstitial seeds. In the present work, two commercially available 125I seed sources, each of approximately 0.5 U, were positioned at two different locations of a polymer gel filled vial.
View Article and Find Full Text PDFThis work seeks to verify multi-shot clinical applications of stereotactic radiosurgery with a Leksell Gamma Knife model C unit employing a polymer gel-MRI based experimental procedure, which has already been shown to be capable of verifying the precision and accuracy of dose delivery in single-shot gamma knife applications. The treatment plan studied in the present work resembles a clinical treatment case of pituitary adenoma using four 8 mm and one 14 mm collimator helmet shots to deliver a prescription dose of 15 Gy to the 50% isodose line (30 Gy maximum dose). For the experimental dose verification of the treatment plan, the same criteria as those used in the clinical treatment planning evaluation were employed.
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
April 2005
Purpose: To evaluate the accuracy of clinical dosimetry planning using commercially available treatment planning systems in (192)Ir high-dose-rate (HDR) breast brachytherapy, with emphasis on skin dose, in view of potential uncertainties owing to the patient finite dimensions and the presence of the lung.
Methods And Materials: A patient-equivalent mathematical phantom was constructed on the basis of the patient computed tomography scan used in the clinical treatment planning procedure. The actual treatment plan delivered to the patient, involving an implant of six plastic catheters and 26 programmed source dwell positions, was simulated by means of the Monte Carlo method.
This work describes an experimental procedure with potential to assess the overall accuracy associated with gamma knife clinical applications, from patient imaging and dosimetry planning to patient positioning and dose delivery using the automated positioning system of a Leksell Gamma Knife model C. The VIPAR polymer gel-MRI dosimetry method is employed due to its inherent three-dimensional feature and linear dose response over the range of gamma knife applications. Different polymer gel vials were irradiated with single shot gamma knife treatment plans using each of the four available collimator helmets to deliver a maximum dose of 30 Gy.
View Article and Find Full Text PDFA durable recommendation for brachytherapy treatment planning systems to account for the effect of tissue, applicator and shielding material heterogeneities exists. As different proposed approaches have not been integrated in clinical treatment planning routine yet, currently utilized systems disregard or, most commonly, do not fully account for the aforementioned effects. Therefore, it is of interest to evaluate the efficacy of current treatment planning in clinical applications susceptible to errors due to heterogeneities.
View Article and Find Full Text PDFThe water equivalence and stable relative energy response of polymer gel dosimeters are usually taken for granted in the relatively high x-ray energy range of external beam radiotherapy based on qualitative indices such as mass and electron density and effective atomic number. However, these favourable dosimetric characteristics are questionable in the energy range of interest to brachytherapy especially in the case of lower energy photon sources such as 103Pd and 125I that are currently utilized. In this work, six representative polymer gel formulations as well as the most commonly used experimental set-up of a LiF TLD detector-solid water phantom are discussed on the basis of mass attenuation and energy absorption coefficients calculated in the energy range of 10 keV-10 MeV with regard to their water equivalence as a phantom and detector material.
View Article and Find Full Text PDFPurpose: In view of the need for dose-validation procedures on each individual intensity-modulated radiation therapy (IMRT) plan, dose-verification measurements by film, by ionization chamber, and by polymer gel-MRI dosimetry were performed for a prostate-treatment plan configuration. Treatment planning system (TPS) calculations were evaluated against dose measurements.
Methods And Materials: Intensity-modulated radiation therapy (IMRT) treatments were planned on a commercial TPS.
The effect of patient inhomogeneities surrounding the oesophagus on the dosimetry planning of an upper thoracic oesophageal 192Ir HDR brachytherapy treatment is studied. The MCNPX Monte Carlo code is used for dosimetry in a patient-equivalent phantom geometry and results are compared in terms of isodose contours as well as dose volume histograms with corresponding calculations by a contemporary treatment planning system software featuring a full TG-43 dose calculation algorithm (PLATO BPS version 14.2.
View Article and Find Full Text PDFA simple, time efficient, analytical model incorporating heterogeneities and body dimensions around a point 192Ir source is generalized for accurate dosimetry around commercially available 192Ir brachytherapy sources. The generalized model was verified in dosimetry of a clinical 192Ir high dose rate prostate monotherapy application, involving 16 catheters and 83 source dwell positions, through comparison with corresponding treatment planning system data. The computational time efficiency and accuracy of the proposed model allowed the assessment of the impact that uncertainties in source dwell positions and catheter reconstruction may have on dose distributions, and how these could potentially affect the clinical outcome.
View Article and Find Full Text PDF