Background: The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods: We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals.
In the era of precision medicine, pharmacogenetics has substantial potential for addressing inter-individual variability in drug responses. Although pharmacogenetics has been a research focus for many years, resulting in the establishment of several formal guidelines, its clinical implementation remains limited to several gene-drug combinations in most countries, including Korea. The main causes of delayed implementation are technical challenges in genotyping and knowledge gaps among healthcare providers; therefore, clinical laboratories play a critical role in the timely implementation of pharmacogenetics.
View Article and Find Full Text PDFBackground: In clinical laboratories, the precision and sensitivity of autoverification technologies are crucial for ensuring reliable diagnostics. Conventional methods have limited sensitivity and applicability, making error detection challenging and reducing laboratory efficiency. This study introduces a machine learning (ML)-based autoverification technology to enhance tumor marker test error detection.
View Article and Find Full Text PDFBackground: In recent decades, the analytical quality of clinical laboratory results has substantially increased because of collaborative efforts. To effectively utilize laboratory results in applications, such as machine learning through big data, understanding the level of harmonization for each test would be beneficial. We aimed to develop a quantitative harmonization index that reflects the harmonization status of real-world laboratory tests.
View Article and Find Full Text PDFObjectives: To evaluate the performance of the Academia-Government Collaboration for Laboratory Medicine Standardization in Korea (KR-STDZN) based on data from KR-STDZN proficiency testing (KR-STDZN-PT) for creatinine over eight years (2015-2022).
Methods: We used KR-STDZN-PT data of creatinine tests from 2015 to 2022. Acceptance of the participating institutions' test results was assessed by calculating the acceptance performance as absolute bias (absBias%), total coefficient of variance (tCV%), and total error (TE%) for each sample using six measurements from each institution and true values of each reference material.
Background: Interstitial lung abnormalities (ILAs) are associated with the risk of progression to interstitial lung diseases (ILDs). Krebs von den Lungen 6 (KL-6) and surfactant protein (SP)-A have been used as biomarkers of ILDs. In this study, we evaluated the levels of these biomarkers and identified their clinical correlations in healthy individuals to assess their usefulness in the diagnosis of ILAs.
View Article and Find Full Text PDFBackground: To ensure valid results of big data research in the medical field, the input laboratory results need to be of high quality. We aimed to establish a strategy for evaluating the quality of laboratory results suitable for big data research.
Methods: We used Korean Association of External Quality Assessment Service (KEQAS) data to retrospectively review multicenter data.
Background: This study investigated the performance evaluation of total prostate specific antigen (tPSA) testing using Cobas Pure integrated solutions system (calibrated against WHO IS 96/670) and the comparison with established measurement systems with different traceability.
Methods: The evaluation was performed in terms of imprecision, linearity, detection limit, and correlation with Alinity i (calibrated against WHO IS 96/670) and Unicel DxI 800 (calibrated against the manufacturer's working calibrators).
Results: Within-laboratory reproducibility and repeatability were observed less than 1.
Background: New creatinine-based estimated glomerular filtration rate (eGFR) equations, including the 2021 Chronic Kidney Disease Epidemiology Collaboration (2021 CKD-EPI) and European Kidney Function Consortium (EKFC) equations, have been introduced recently. We assessed the performance of the 2021 CKD-EPI and EKFC equations in the Korean population.
Methods: We analyzed 1,654 Korean patients aged ≥18 years who underwent chromium-51-ethylenediamine tetraacetic acid GFR measurements (mGFR).
Background: Small dense low-density lipoprotein (sdLDL) possesses atherogenic potential and is predicted to be susceptible to atherogenic modifications, which further increases its atherogenicity. However, studies on the association between measured or estimated sdLDL cholesterol (sdLDL-C) levels and atherogenic modification in diverse population groups are lacking.
Methods: Surplus serum samples were collected from male subjects with type 2 diabetes mellitus (DM) under treatment (n = 300) and without DM (non-DM; n = 150).
Background: High LDL-cholesterol (LDL-C) is an established risk factor for cardiovascular disease and is considered an important therapeutic target. It can be measured directly or calculated from the results of other lipid tests. The Friedewald formula is the most widely used formula for calculating LDL-C.
View Article and Find Full Text PDFBackground: Turnaround time (TAT) is one of the most important indicators of laboratory quality. For the outpatient routine chemistry tests whose results are checked by clinicians on the same day, we set a quality goal that >90% of these samples should be reported within 60 min. As more than 20% of the samples failed to achieve this goal in 2020, we introduced an additional autoanalyzer and a real-time monitoring system to improve this rate.
View Article and Find Full Text PDFBackground: The top-down (TD) approach using internal quality control (IQC) data is regarded a practical method for estimating measurement uncertainty (MU) in clinical laboratories. We estimated the MU of 14 clinical chemistry analytes using the TD approach and evaluated the effect of lot changes on the MU.
Methods: MU values were estimated using subgrouping by reagent lot changes or using the data as a whole, and both methods were compared.
Background: Anti-Müllerian hormone (AMH) is one of the most reliable markers of ovarian reserve. Automated AMH assays are widely used in clinical laboratories, but reference intervals for the Elecsys AMH assay for Asian populations have not yet been determined. We aimed to determine reference intervals in healthy Korean women.
View Article and Find Full Text PDFObjective: This study aimed to examine the intra- and interlaboratory variations of cycle threshold (Ct) values using the nationwide proficiency testing for SARS-CoV-2.
Methods: Triplicated strong-positive contrived samples duplicated weak-positive contrived samples, and 2 negative samples were transported to participating laboratories in October 2021.
Results: A total of 232 laboratories responded.
Background: We established high-sensitivity cardiac troponin I (hsTnI) 99th percentile upper reference limits (URLs) for the Centaur XPT High-Sensitivity Troponin I assay (Centaur hsTnI; Siemens, Erlangen, Germany) and Atellica IM High-Sensitivity Troponin I assay (Atellica hsTnI; Siemens) and assessed the effect of outlier elimination.
Methods: The reference population comprised 380 men and 387 women, satisfying the strict systematic reference population criteria. After reference population verification by the N-terminal pro-B-type natriuretic peptide (NT-proBNP) assay, 99th percentile URLs for Centaur hsTnI and Atellica hsTnI were calculated before and after outlier elimination.
Background: Automated microscopic platforms are increasingly used in clinical laboratories for rapid analysis of samples. However, it is important to present the results quantitatively or semiquantitatively because automated platforms use various technologies for analysis as well as different sediment preparation methods. The results of cell counting using an on screen image review program for the cobas u 701 analyzer (Roche Diagnostics Interna-tional, Rotkreuz, Switzerland) differed from those obtained by manual microscopic examination (MME).
View Article and Find Full Text PDF