Publications by authors named "Sagar Suman Panda"

A validated ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed for the first-ever simultaneous analysis of neratinib, curcumin and internal standard (imatinib) using acetonitrile as the liquid-liquid extraction medium. On a BEH C18 (100 mm × 2.1 mm, 1.

View Article and Find Full Text PDF

A chemometrics-oriented green ultra-performance liquid chromatography-mass spectrometry/mass spectrometry method was developed and validated for the first-time simultaneous estimation of capecitabine (CAP) and lapatinib (LPB) along with imatinib (as internal standard (IS)) in rat plasma. Analytes were extracted using ethyl acetate as the liquid-liquid extraction media. In the pre-development phase, principles of analytical eco-scale were used to confirm method greenness.

View Article and Find Full Text PDF

Neratinib, a tyrosine kinase inhibitor, was very recently approved by USFDA in 2017 as an anticancer drug to treat of HER2 positive breast cancers. The present work provides an account on the development of a validated bioanalytical UPLC-MS/MS method for quantification of neratinib and internal standard (imatinib) in rat plasma and tissue homogenates. A UPLC having a 100 mm C18 column (1.

View Article and Find Full Text PDF

A stability-indicating liquid chromatographic method was developed employing the principles of quality by design (QbD) to quantify vilazodone hydrochloride (VLN) in pharmaceutical dosage form. A Box-Behnken experimental design was employed to establish optimum conditions including method robustness by selecting organic phase proportion (%), mobile phase flow rate (mL/min) and pH of buffer as the factors, to study their effect on plate number as the response variable. Chromatography was performed on a C-18 column using methanol:phosphate buffer of pH 7.

View Article and Find Full Text PDF

The present studies describe the systematic quality by design (QbD)-oriented development and validation of a simple, rapid, sensitive and cost-effective reversed-phase HPLC bioanalytical method for nevirapine in rat plasma. Chromatographic separation was carried out on a C18 column using isocratic 68:9:23% v/v elution of methanol, acetonitrile and water (pH 3, adjusted by orthophosphoric acid) at a flow rate of 1.0 mL/min using UV detection at 230 nm.

View Article and Find Full Text PDF

Quality by design (QbD) approach thrives to achieve an assured and predicted quality product. A stability-indicating reversed phase ultrafast liquid chromatographic method was developed using the principles of QbD to quantify telaprevir (TEL) in pharmaceutical dosage form. A Box-Behnken experimental design was employed for identifying optimum chromatographic conditions by assessing the method robustness by selecting organic phase composition (%), mobile phase flow rate (mL/min) and pH of the borate buffer as the factors, to study their effect on the responses like retention time, theoretical plate count and tailing factor.

View Article and Find Full Text PDF

An ultra-fast liquid chromatographic method and two UV spectroscopic methods were developed for the determination of cephalexin monohydrate in pharmaceutical dosage forms. Isocratic separation was performed on an Enable C18G column (250 mm × 4.6 mm i.

View Article and Find Full Text PDF

A simple, precise, and accurate isocratic RP-UFLC stability-indicating assay method has been developed to determine trospium chloride in tablet dosage form. Isocratic separation was achieved on an Enable-C18G (250 mm × 4.6 mm i.

View Article and Find Full Text PDF

A simple, precise and accurate isocratic RP-HPLC stability-indicating assay method has been developed to determine diclofenac potassium and metaxalone in their combined dosage forms. Isocratic separation was achieved on a Hibar-C(18), Lichrosphere-100(®) (250 mm × 4.6 mm i.

View Article and Find Full Text PDF