Medical applications of radiation have been widely spread until now. However, the exposure of medical staff is sometimes overlooked, because treatment of patients is the first priority. The purpose of this study is to develop a small and light monitor that can measure the energy spectrum and dose of gamma-rays at the same time in real-time for medical applications.
View Article and Find Full Text PDFBoron neutron capture therapy (BNCT) is a cell-selective particle therapy for cancer using boron containing drugs. Boron compounds are accumulated in high concentration of tens ppm level of boron in target tumors to cause lethal damage to tumor tissue. The examination of boron distribution in target tumor and normal tissue is important to evaluate the efficiency of therapy.
View Article and Find Full Text PDFThe purpose of this study is to develop a portable monitor that can measure the energy spectrum and dose of gamma-rays simultaneously in real time for the benefit of medical staff who must work in clinical radiation environments. For this purpose, we have developed a prototype monitor using a CsI (Tl) scintillator combined with a multi-pixel photon counter (MPPC). For real-time measurement, we employed an improved sequential Bayesian estimation (k-α method) to convert the measured pulse height spectrum into an energy spectrum.
View Article and Find Full Text PDFBoron neutron capture therapy (BNCT) is a non-invasive type of radiation therapy developed for humans and translated to veterinary medicine. However, clinical trials on BNCT for patients with brain tumors are on-going. To improve the therapeutic efficacy of BNCT for brain tumors, we developed a boron delivery system that involves the cerebrospinal fluid (CSF), in contrast to the conventional method that involves intravenous (IV) administration.
View Article and Find Full Text PDFRecently, exploitation of cerebrospinal fluid (CSF) circulation has become increasingly recognized as a feasible strategy to solve the challenges involved in drug delivery for treating brain tumors. Boron neutron capture therapy (BNCT) also faces challenges associated with the development of an efficient delivery system for boron, especially to brain tumors. Our laboratory has been developing a system for boron delivery to brain cells using CSF, which we call the "boron CSF administration method".
View Article and Find Full Text PDFBoron Neutron Capture Therapy (BNCT) is a promising cancer therapy, which has recently been in practical use in Japan especially using an accelerator. In BNCT real-time measurement of local boron dose is required. In the present study, a novel design of a SPECT system for BNCT (BNCT-SPECT) has been carried out to realize estimation of the local boron dose, i.
View Article and Find Full Text PDFBased on the activation method using Ga(n,γ)Ga reaction, a cubic neutron flux intensity detector for epi-thermal neutrons was designed for boron neutron capture therapy (BNCT), and experimentally tested with a prototype detector in a neutron field produced at OKTAVIAN facility of Osaka University, Japan. The experimental test results and related analysis indicated that the performance of the detector was confirmed to be acceptable in the neutron field of BNCT. Practically, the neutron flux intensity mainly covering from 0.
View Article and Find Full Text PDFRadiat Prot Dosimetry
August 2018
Boron neutron capture therapy is known to be an effective radiation cancer therapy that requires neutron irradiation. A neutron field generated by an accelerator-based neutron source has various energy spectra, and it is necessary to evaluate the neutron spectrum in the treatment field. However, the method used to measure the neutron spectrum in the treatment field is not well established.
View Article and Find Full Text PDFRadiat Prot Dosimetry
December 2017
A novel optically stimulated luminescence (OSL) detector containing isotopically enriched boron was developed for thermal neutron dosimetry. Alumina containing isotopically enriched boron (Al2O3:B) was synthesised by the sol-gel method. The Al2O3:B was annealed up to ~1800 K.