Background: Multiple studies and meta-analyses have described the technical and clinical outcomes in large cohorts of aneurysm patients treated with flow diverters (FDs). Variations in evaluation methodology complicate making comparisons among studies, hinder understanding of the device behavior, and pose an obstacle in the assessment of further advances in FD therapy.
Methods: A multidisciplinary panel of neurointerventionalists, imaging experts, and neuroradiologists convened with the goal of establishing consensus recommendations for the standardization of image analyses in FD studies.
Background And Purpose: The optimal antiplatelet regimen after flow diverter treatment of cerebral aneurysms is still a matter of debate. A single antiplatelet therapy might be advantageous in determined clinical scenarios. This study evaluated the efficacy and safety of prasugrel single antiplatelet therapy versus aspirin and clopidogrel dual antiplatelet therapy.
View Article and Find Full Text PDFRaising public awareness about the relevance of supporting sustainable practices is required owing to the phenomena of global warming caused by the rising production of greenhouse gases. The healthcare sector generates a relevant proportion of the total carbon emissions in developed countries, and radiology is estimated to be a major contributor to this carbon footprint. Neuroradiology markedly contributes to this negative environmental effect, as this radiological subspecialty generates a high proportion of diagnostic and interventional imaging procedures, the majority of them requiring high energy-intensive equipment.
View Article and Find Full Text PDFBackground: The aim of this study was to evaluate the overall rates of braid changes associated with flow diverter (FD) treatment for intracranial aneurysms (IAs). Additionally, we sought to provide an overview of the currently reported definitions related to these complications.
Methods: A systematic search was conducted from the inception of relevant literature up to April 2023, encompassing six databases.
Background: The anterior communicating artery (AComm) region is the most common site of intracranial aneurysms, with increased rupture risk compared with other locations. Overall, flow diverters present as a safe and efficacious treatment for intracranial aneurysms, but there is paucity of data for their use in the treatment of unruptured AComm aneurysms. We present the largest multicentric analysis evaluating the outcomes of flow diverters in AComm aneurysm treatment.
View Article and Find Full Text PDFIn this review article, we aim to provide a summary of the discoveries and developments that were instrumental in the evolution of the Neurointerventional field. We begin with developments in the advent of Diagnostic Cerebral Angiography and progress to cerebral aneurysm treatment, embolization in AVMs and ischemic stroke treatment. In the process we discuss many persons who were key in the development and maturation of the field.
View Article and Find Full Text PDFObjective: The aim of the study was to investigate the influence of facemask treatment with skeletal anchorage on the temporomandibular joint (TMJ) using magnetic resonance imaging (MRI), in patients with Class III malocclusion, accompanied by maxillary retrusion.
Methods: Fifteen patients with a mean age of 12.1±1.
Background: Flow diversion is an innovative and increasingly used technique for the treatment of intracranial aneurysms. New flow diverters (FDs) are being introduced to improve the safety and efficacy of this treatment. The aim of this study was to assess the safety, feasibility, and efficacy of the new Pipeline Vantage (PV) FD.
View Article and Find Full Text PDFFlow diversion is increasingly used as an endovascular treatment for intracranial aneurysms. In this retrospective multicenter study, we analyzed the safety and efficacy of the treatment of intracranial, unruptured, or previously treated but recanalized aneurysms using Flow Re-Direction Endoluminal Device (FRED) Jr with emphasis on midterm results. Clinical and radiological records of 150 patients harboring 159 aneurysms treated with FRED Jr at six centers between October 2014 and February 2020 were reviewed and consecutively included.
View Article and Find Full Text PDFBackground And Purpose: Women's representation in medicine has increased over time yet the proportion of women practicing neurointervention remains low. We conducted an anonymous online survey through which we could explore the gender gap in neurointervention, identify potential issues, difficulties, or obstacles women might face, and evaluate if men encounter similar issues.
Methods: An online questionnaire was designed in SurveyMonkey®.
Herein, we describe the use of a novel multiplug flow control technique for the curative transarterial embolisation of cerebrovascular malformations using liquid embolic agents (LEAs). The idea behind the use of this technique is to substantially control or arrest flow during LEA injection, with multiple plugs simultaneously formed from microcatheters that are placed within all or multiple feeders, so that the penetration of LEAs is facilitated, with flow control decreasing the washout of a malformation. This technique enables the complete occlusion of a vascular malformation in a shorter injection time than that in other methods because penetration is achieved faster.
View Article and Find Full Text PDFHerein, we describe the use of a novel multiplug flow control technique for the curative transarterial embolisation of cerebrovascular malformations using liquid embolic agents (LEAs). The idea behind the use of this technique is to substantially control or arrest flow during LEA injection, with multiple plugs simultaneously formed from microcatheters that are placed within all or multiple feeders, so that the penetration of LEAs is facilitated, with flow control decreasing the washout of a malformation. This technique enables the complete occlusion of a vascular malformation in a shorter injection time than that in other methods because penetration is achieved faster.
View Article and Find Full Text PDFPurpose: Our aim was to determine the long-term safety and efficacy of the Flow Re-Direction Endoluminal Device (FRED) in this multicenter study with prospective design.
Materials-method: This study included 136 consecutive patients with 155 aneurysms treated between March 2013 and June 2016 in 10 centers. Twenty-two (16.
Background: Balloon-assisted techniques can improve the endovascular treatment of cerebrospinal vascular malformations. The aim of this study was to report the first clinical multicenter experience with the new Scepter Mini dual-lumen microballoon catheter.
Methods: Patients with cerebral or spinal vascular malformations treated with the Scepter Mini at seven European neurovascular centers were retrospectively reviewed.
Wide-necked bifurcation aneurysms (WNBAs) make up 26-36% of all brain aneurysms. Treatments for WNBAs pose unique challenges due to the need to preserve major bifurcation vessels while achieving a durable occlusion of the aneurysm. Intrasaccular flow disruption is an innovative technique for the treatment of WNBAs.
View Article and Find Full Text PDFIntroduction: The Woven EndoBridge Intrasaccular Therapy (WEB-IT) Study is a pivotal, prospective, single-arm, investigational device exemption study designed to evaluate the safety and effectiveness of the WEB device for the treatment of wide-neck bifurcation aneurysms.
Methods: One-hundred and fifty patients with wide-neck bifurcation aneurysms were enrolled at 21 US and six international centers. Angiograms from the index procedure, and 6-month and 1-year follow-up visits were all reviewed by a core laboratory.
AJNR Am J Neuroradiol
September 2018
Background And Purpose: Serpentine aneurysms are partially thrombosed aneurysms with an eccentrically located tortuous intra-aneurysmal vascular channel. The large size, distinctive neck anatomy, and supply of the brain parenchyma by the outflow tract pose technical challenges in treatment. The aim of this study was to discuss the endovascular treatment results and illustrate the dynamic nature of serpentine aneurysms.
View Article and Find Full Text PDFBackground And Purpose: Flow diverters are emerging as an endovascular treatment alternative for proximally located intracranial aneurysms. However, treatment of aneurysms at and beyond the circle of Willis is not well-established. We assessed the clinical safety and efficacy of the Flow Re-Direction Endoluminal Device Jr (FRED Jr) dedicated to small-vessel diameters between 2.
View Article and Find Full Text PDFBackground: Early and mid-term safety and efficacy of aneurysm treatment with the Pipeline Embolization Device (PED) has been well demonstrated in prior studies.
Objective: To present 5-yr follow-up for patients treated in the Pipeline for Uncoilable or Failed Aneurysms clinical trial.
Methods: In our prospective, multicenter trial, 109 complex internal carotid artery (ICA) aneurysms in 107 subjects were treated with the PED.