We report the design and development of a data acquisition and control system for high-speed acquisition of weak, backscattered differential signals and synchronized sequential operation of all subsystems of a tunable, mid-infrared Differential Absorption Lidar (DIAL) system. The presence of a low-level concentration of chemical species results in weak differential return signals. The differential signal also varies dynamically with respect to background atmospheric conditions.
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
December 2011
Mie lidar system is developed at Laser Science and Technology Centre, Delhi (28.38°N, 77.12°E) by using minimal number of commercially available off-the-shelf components.