Publications by authors named "S T Senthilmohan"

We report a new, fast, sensitive variation of the total oxyradical scavenging capacity (TOSC) assay for measuring the antioxidant capacity of pure compounds, plant extracts and biological fluids using selected ion flow tube mass spectrometry (SIFT-MS). The TOSC assay examines the partial inhibition of ethene formation in the presence of antioxidants that compete with alpha-keto-gamma-methiolbutyric acid (KMBA) for reactive oxygen species. The SIFT-MS-TOSC assay takes 15 s for each ethene analysis and the time interval between consecutive analyses is 20 s.

View Article and Find Full Text PDF

When neutrophils phagocytose bacteria, they generate the cytotoxic agent hypochlorous acid (HOCl). The specific role that HOCl plays in bacterial killing is unclear. In the phagosome, it should react with neutrophil proteins to form protein chloramines and dichloramines.

View Article and Find Full Text PDF

Selected ion flow tube mass spectrometry (SIFT-MS) is a sensitive technique capable of measuring volatile compounds (VCs) in complex gas mixtures in real time; it is now being applied to breath analysis. We investigated the effect of inhalers containing chlorofluorocarbons (CFCs) on the detection and measurement of haloamines in human breath. SIFT-MS mass scans (MS) and selected ion monitoring (SIM) scans were performed on three healthy non-smoking volunteers before and after inhalation of the following medications: Combiventtrade mark metered-dose inhaler (MDI) (CFC-containing); Ventolintrade mark MDI (CFC-free); Atroventtrade mark MDI (CFC-free), Beclazonetrade mark MDI (CFC-containing); Duolintrade mark nebuliser.

View Article and Find Full Text PDF

We report a fast, sensitive, real-time method to measure monobromamine, monochloramine and dichloramine using selected ion flow tube mass spectrometry (SIFT-MS). Relative rate coefficients and product distributions are reported for the reagent ions H3O+ and O2 +. Rapid reactions with the haloamines were observed with H3O+ and O2 + but no fast reaction was found with NO+.

View Article and Find Full Text PDF

Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS) is an analytical technique for real-time quantification of trace gases in air or breath samples. SIFT-MS system thus offers unique potential for early, rapid detection of disease states. Identification of volatile organic compound (VOC) masses that contribute strongly towards a successful classification clearly highlights potential new biomarkers.

View Article and Find Full Text PDF