Publications by authors named "S Pirner"

Charge heterogeneity among therapeutic monoclonal antibodies (mAbs) is considered an important critical quality attribute and requires careful characterization to ensure safe and efficacious drug products. The charge heterogeneity among mAbs is the result of chemical and enzymatic post-translational modifications and leads to the formation of acidic and basic variants that can be characterized using cation exchange chromatography (CEX). Recently, the use of mass spectrometry-compatible salt-mediated pH gradients has gained increased attention to elute the proteins from the charged stationary phase material.

View Article and Find Full Text PDF

This work illustrates the benefits and limitations of using ultra-short reversed phase liquid chromatography (RPLC) columns for the characterization of various complex bispecific antibodies after prolonged thermal stress at the middle-up level of analysis. First, we have demonstrated that alternative organic modifiers, such as isopropanol, can be used in RPLC mode without generating excessive pressure, thanks to the prototype 10 × 2.1 mm, 2.

View Article and Find Full Text PDF

Monte-Carlo (MC) simulations are considered to be the most accurate method for calculating dose distributions in radiotherapy. Its clinical application, however, still is limited by the long runtimes conventional implementations of MC algorithms require to deliver sufficiently accurate results on high resolution imaging data. In order to overcome this obstacle we developed the software-package PhiMC, which is capable of computing precise dose distributions in a sub-minute time-frame by leveraging the potential of modern many- and multi-core CPU-based computers.

View Article and Find Full Text PDF

The generation of relativistic attosecond electron bunches is observed in three-dimensional, relativistic particle-in-cell simulations of the interaction of intense laser light with droplets. The electron bunches are emitted under certain angles which depend on the ratios of droplet radius to wavelength and plasma frequency to laser frequency. The mechanism behind the multi-MeV attosecond electron bunch generation is investigated using Mie theory.

View Article and Find Full Text PDF

Manual segmentation of computed tomography (CT) datasets was performed for robot-assisted endoscope movement during functional endoscopic sinus surgery (FESS). Segmented 3D models are needed for the robots' workspace definition. A total of 50 preselected CT datasets were each segmented in 150-200 coronal slices with 24 landmarks being set.

View Article and Find Full Text PDF