Background: Matrix-induced autologous chondrocyte implantation (MACI) has demonstrated encouraging outcomes in the treatment of knee cartilage defects, although limited research is available on its longer term (≥10 years) sustainability in the patellofemoral joint.
Purpose: To report the clinical and radiological outcomes at ≥10 years in a prospectively recruited cohort of patients undergoing MACI in the patellofemoral joint and compare outcomes in patients undergoing MACI on the patella versus the trochlea.
Study Design: Case series; Level of evidence, 4.
Real-time monitoring of critical quality attributes, such as residual water in granules after drying which can be determined through loss-on-drying (LOD), during wet granulation and drying is essential in continuous manufacturing. Near-infrared (NIR) spectroscopy has been widely used as process analytical technology (PAT) for in-line LOD monitoring. This study aims to develop and apply a model for predicting the LOD based on process parameters.
View Article and Find Full Text PDFIn this study, deep UV resonance Raman spectroscopy (DUV-RRS) was coupled with high performance liquid chromatography (HPLC) to be applied in the field of pharmaceutical analysis. Naproxen, Metformin and Epirubicin were employed as active pharmaceutical ingredients (APIs) covering different areas of the pharmacological spectrum. Raman signals were successfully generated and attributed to the test substances, even in the presence of the dominant solvent bands of the mobile phase.
View Article and Find Full Text PDFExternal lubrication is an alternative to internal lubrication and its related detrimental effects on properties of tablets like tensile strength (TS). However, to date there are hardly any systematic investigations on external lubrication of mini-tablets on rotary tablet presses. Aim of this study was the systematic investigation of the impact of parameters tableting pressure, tableting speed, dosing rate and air pressure on the TS of mini-tablets.
View Article and Find Full Text PDFPurpose: An MRI-based scoring tool assessing surgical repair after proximal hamstring avulsions may provide benefit in the context of research, while serial post-operative MRI will provide insight of what to expect in the clinical context of early re-injury requiring imaging. This study developed and assessed the reliability of a Proximal Hamstring Objective Magnetic Resonance Imaging Score (PHOMRIS), further assessing MRI-based repair status and its correlation with patient-reported outcome.
Methods: 15 patients that underwent proximal hamstring surgical repair underwent MRI and clinical review pre-operatively and at 3-, 6- and 12-months.