Publications by authors named "S Mimount"

Article Synopsis
  • The study focuses on the residence time distribution (RTD) of a radiotracer to analyze the performance of packed distillation columns in industrial processes.
  • An experiment was conducted using Technitium-99 radiotracer and monitored with eight scintillation detectors, employing various data corrections for accuracy.
  • Two mathematical models were tested using IAEA RTD software, ultimately selecting the one that best matched the experimental data to accurately determine the RTD.