The paper presents the design and implementation of an electromagnetic field monitoring sensor for the measurement of the Terrestrial Truncked Radio (TETRA) signals using low-cost software defined radio (SDR) platforms. The sensor includes: an SDR platform, a Global Positioning System (GPS) module and a hardware control module. Several SDR platforms having different resolutions of the analog-digital converters were tested in the first phase.
View Article and Find Full Text PDFA suitable metric to describe human exposure to microwaves emitted by wireless communication devices is still incomplete. By using both theoretical analysis and experimental validation (in controlled and real deployed networks), we analyze and compare the specificity of exposure due to data transmissions in different configurations of fourth and fifth generation wireless fidelity (Wi-Fi) standards in the proximity of a mobile device. Measurements made use of the capability of the amplitude probability density incorporated in a real-time spectrum analyzer, proving its agility of highlighting different user exposure profiles.
View Article and Find Full Text PDFJ Environ Health Sci Eng
December 2015
Background: The influence of electromagnetic exposure on mammalian tissues was approached as a public health issue aiming to reveal the putative side effect of 50 Hz industrial and domestic supply source (i) during aliments storage near such sources; (ii) in people staying couple of hours in the proximity of conducting wires.
Materials And Methods: Fluorescence emission based thermal sensor was used to emphasize temperature dynamics of fresh meat samples during controlled electromagnetic exposure in Helmholtz coils adjusted to deliver 50 Hz / (4÷10) mT electromagnetic field in their inner volume. Fluoroptic temperature probe with 0.
Electromagn Biol Med
September 2015
Technical literature provides numerous studies concerning radiofrequency exposure measurements for various radio communication devices, but there are few studies related to exposure of personnel operating military radio equipment. In order to evaluate exposure and identify cases when safety requirements are not entirely met, both measurements and simulations are needed for accurate results. Moreover, given the technical characteristics of the radio devices used in the military, personnel mainly operate in the near-field region so both measurements and simulation becomes more complex.
View Article and Find Full Text PDFWith the development of radiofrequency technology, radiating quasi-stochastic signals like the wireless local area networks (WLAN), a proper procedure of exposure level assessment is needed. No standardised procedure exists at the moment. While channel power measurement proved to overestimate the field strength, weighting techniques were proposed.
View Article and Find Full Text PDF