Membrane distillation (MD) scale-up is challenged by ineffective heat recovery and the temperature polarization effect. Direct contact membrane distillation (DCMD) modules suffer high thermal conduction losses due to feed flow direction along the length of the membrane, resulting in low thermal efficiency. We propose a novel module design named coiled hollow fiber (CHF) to decouple the flow direction from the membrane surface in hollow fiber (HF) DCMD.
View Article and Find Full Text PDFOptimal spacer design enhances the filtration performance in spiral-wound modules by controlling the local hydrodynamics inside the filtration channel. A novel airfoil feed spacer design fabricated using 3D-printing technology is proposed in this study. The design is a ladder-shaped configuration with primary airfoil-shaped filaments facing the incoming feed flow.
View Article and Find Full Text PDFArtificial lung technology is advancing at a startling rate raising hopes that it would better serve the needs of those requiring respiratory support. Whether to assist the healing of an injured lung, support patients to lung transplantation, or to entirely replace native lung function, safe and effective artificial lungs are sought. After 200 years of bioengineering progress, artificial lungs are closer than ever before to meet this demand which has risen exponentially due to the COVID-19 crisis.
View Article and Find Full Text PDFFeed spacers are the critical components of any spiral-wound filtration module, dictating the filtration performance. Three spacer designs, namely a non-woven commercial spacer (varying filament cross-section), a symmetric pillar spacer, and a novel hole-pillar spacer (constant filament diameter) were studied using Direct Numerical Simulations (DNS), 3-D printed and subsequently experimentally tested in a lab-scale ultrafiltration set-up with high biofouling potential feed water at various feed pressures. Independent of the applied pressure, the novel hole-pillar spacer showed initially the lowest feed channel pressure drop, the lowest shear stress, and the highest permeate flux compared to the commercial and pillar spacers.
View Article and Find Full Text PDFAn appropriate spacer design helps in minimizing membrane fouling which remains the major obstacle in forward osmosis (FO) systems. In the present study, the performance of a hole-type spacer (having holes at the filament intersections) was evaluated in a FO system and compared to a standard spacer design (without holes). The hole-type spacer exhibited slightly higher water flux and reverse solute flux (RSF) when Milli-Q water was used as feed solution and varied sodium chloride concentrations as draw solution.
View Article and Find Full Text PDF