Pancreatic cancer is the fourth leading cause of cancer-related death, with nearly 60,000 cases each year and less than a 10% 5-year overall survival rate. Radiation therapy (RT) is highly beneficial as a local-regional anticancer treatment. As anatomical variation is of great concern, motion management techniques, such as DIBH, are commonly used to minimize OARs toxicities; however, the variability between DIBHs has not been well studied.
View Article and Find Full Text PDFAs cone-beam computed tomography (CBCT) has become the localization method for a majority of cases, the indications for diode-based confirmation of accurate patient set-up and treatment are now limited and must be balanced between proper resource allocation and optimizing efficiency without compromising safety. We undertook a de-implementation quality improvement project to discontinue routine diode use in non-intensity modulated radiotherapy (IMRT) cases in favor of tailored selection of scenarios where diodes may be useful. After analysis of safety reports from the last 5 years, literature review, and stakeholder discussions, our safety and quality (SAQ) committee introduced a recommendation to limit diode use to specific scenarios in which in vivo verification may add value to standard quality assurance (QA) processes.
View Article and Find Full Text PDFPurpose: To develop the safest possible environment for treating urgent patients with COVID-19 requiring radiation, we describe the unique construction of negative air pressure computed tomography simulator and linear accelerator treatment vaults in addition to screening, delay, and treatment protocols and their evolution over the course of the COVID-19 pandemic.
Methods And Materials: Construction of large high-efficiency particulate air filter air-flow systems into existing ductwork in computed tomography simulator rooms and photon and proton treatment vaults was completed to create negative-pressure rooms. An asymptomatic COVID-19 screening protocol was implemented for all patients before initiation of treatment.
Purpose: In this study, we aim to further evaluate the accuracy of ultrasound tracking for intra-fraction pancreatic tumor motion during radiotherapy by a phantom-based study.
Methods: Twelve patients with pancreatic cancer who were treated with stereotactic body radiation therapy were enrolled in this study. The displacement points of the respiratory cycle were acquired from 4DCT and transferred to a motion platform to mimic realistic breathing movements in our phantom study.