Background: The plethysmographic shift volume-flow loop (sR-loop) measured during tidal breathing allows the determination of several lung function parameters such as the effective specific airway resistance (sR), calculated from the ratio of the integral of the resistive aerodynamic specific work of breathing (sWOB) and the integral of the corresponding flow-volume loop. However, computing the inspiratory and expiratory areas of the sR-loop separately permits the determination of further parameters of airway dynamics. Therefore, we aimed to define the discriminating diagnostic power of the inspiratory and expiratory sWOB (sWOB, sWOB), as well as of the inspiratory and expiratory sR (sR and sR ), for discriminating different functional phenotypes of chronic obstructive lung diseases.
View Article and Find Full Text PDFThe objectives of the present study were to evaluate the discriminating power of spirometric and plethysmographic lung function parameters to differenciate the diagnosis of asthma, ACO, COPD, and to define functional characteristics for more precise classification of obstructive lung diseases. From the databases of 4 centers, a total of 756 lung function tests (194 healthy subjects, 175 with asthma, 71 with ACO, 78 with COPD and 238 with CF) were collected, and gradients among combinations of target parameters from spirometry (forced expiratory volume one second: FEV1; FEV1/forced vital capacity: FEV1/FVC; forced expiratory flow between 25-75% FVC: FEF25-75), and plethysmography (effective, resistive airway resistance: sReff; aerodynamic work of breathing at rest: sWOB), separately for in- and expiration (sReffIN, sReffEX, sWOBin, sWOBex) as well as static lung volumes (total lung capacity: TLC; functional residual capacity: FRCpleth; residual volume: RV), the control of breathing (mouth occlusion pressure: P0.1; mean inspiratory flow: VT/TI; the inspiratory to total time ratio: TI/Ttot) and the inspiratory impedance (Zinpleth = P0.
View Article and Find Full Text PDFArch Dis Child Fetal Neonatal Ed
March 2023
Objective: Newborn screening (NBS) for cystic fibrosis (CF) was introduced in Switzerland in 2011 based on an immunoreactive trypsinogen (IRT)-DNA-IRT protocol. CF diagnosis was confirmed by sweat test and/or genetics but remained inconclusive for some newborns (cystic fibrosis transmembrane conductance regulator related metabolic syndrome (CRMS)/CF screen positive, inconclusive diagnosis (CFSPID)). We aimed to (1) Describe IRT levels in healthy newborns in the first year of life and by gestational age (GA), and (2) Compare IRT at two time points between healthy newborns and newborns with CF and CRMS/CFSPID.
View Article and Find Full Text PDFWe report on an 8-year-old girl with severe developmental and epileptic encephalopathy due to the compound heterozygous null variants p.(Gln661*) and p.(Leu830Profs*2) in GRIN2A resulting in a knockout of the human GluN2A subunit of the N-methyl-D-aspartate receptor.
View Article and Find Full Text PDF