The purpose of this study was to validate an electronic portal imaging device (EPID) based 3-dimensional (3D) dosimetry system for the commissioning of volumetric modulated arc therapy (VMAT) delivery for flattening filter (FF) and flattening filter free (FFF) modalities based on test suites developed according to American Association of Physicists in Medicine Task Group 119 (AAPM TG 119) and pre-treatment patient specific quality assurance (PSQA).With ionisation chamber, multiple-point measurement in various planes becomes extremely difficult and time-consuming, necessitating repeated exposure of the plan. The average agreement between measured and planned doses for TG plans is recommended to be within 3%, and both the ionisation chamber and PerFRACTION™ measurement were well within this prescribed limit.
View Article and Find Full Text PDFRadiation protection is essential to minimize the harmful effects of ionizing radiation. Lead equivalent apron is one of the common protective devices to reduce the occupational risk of radiation exposure. The aim of the study is to analyse the percentage attenuation of 0.
View Article and Find Full Text PDFTo analyse the fetal dose in all three trimesters in patients treated for brain tumors during pregnancy, a modified rando phantom representing three different trimesters was used with provisions for insertion of ion-chamber and Optically Simulated Luminescence Dosimeter (OSLD). The measurement regions were chosen at the level of fundus, umbilicus and pubis. Seven different treatment plans with 6FF and 6FFF beam energies were generated.
View Article and Find Full Text PDFAim: The aim of this study was to measure the dose to planning target and organ at risk (OAR) using Alderson Rando phantom for various treatment techniques in left breast radiotherapy and to estimate the secondary cancer incidence.
Materials And Methods: Eleven different combinations of plans containing four techniques (three dimensional conformal radiotherapy, intensity-modulated radiation therapy [IMRT], volumetric modulated arc therapy [VMAT], and combination of 3DCRT and VMAT plans (HYBRID)) were created with 6 MV FF and 6 MV FFF (flattening filter and flattening filter-free) photon energies in phantom. Planned target volume and OAR doses in 23 different locations were measured using optically stimulated luminescence dosimeter (OSLD) and EBT3 films.
Background: The purpose of this study was to evaluate the surface dose (SD) of 6 and 10 MV flattening filter beam (FF) and flattening filter free (FFF) beam for different square field sizes in three Beam-matched medical linear accelerators using a parallel-plate ionization chamber.
Materials And Methods: The experiment was carried out in a phantom composed of 40×40 cm2 solid Water slabs of varying thickness. Further sheets of solid water phantom were added to take readings in the build-up region for both SSD and SAD technique.
© LitMetric 2025. All rights reserved.