Publications by authors named "Ryosuke Kohno"

Article Synopsis
  • The feasibility study demonstrated that carbon-ion radiotherapy (CIRT) is both safe and effective for treating head and neck cancer.
  • It highlights the innovative approach of using linear energy transfer (LET) painting in the therapy.
  • This research is the first step toward integrating CIRT with LET painting into regular clinical practice.
View Article and Find Full Text PDF

Purpose: Dose-averaged linear energy transfer (LET) is one of the important factors in determining clinical outcomes for carbon-ion radiation therapy. Innovative LET painting (LP) has been developed as an advanced form of conventional intensity modulated carbon-ion radiation therapy (IMIT) at the QST Hospital. The study had 2 motivations: to increase the minimum LET (LET) and to improve uniformity of the LET distribution within the gross tumor volume (GTV) by using LP treatment plans for patients with head and neck cancer while maintaining the relative biologic effectiveness (RBE)-weighted dose coverage within the planning tumor volume (PTV) the same as in the conventional IMIT plan.

View Article and Find Full Text PDF

Purpose: To evaluate the outcomes of particle therapy in cancer patients with cardiac implantable electronic devices (CIEDs).

Materials And Methods: From April 2001 to March 2013, 19,585 patients were treated with proton beam therapy (PBT) or carbon ion therapy (CIT) at 8 institutions. Of these, 69 patients (0.

View Article and Find Full Text PDF

The effects of a magnetic field longitudinal to the ion beam track on the generation of hydroxyl radicals (•OH) and hydrogen peroxide (HO) in water were investigated. A longitudinal magnetic field was reported to enhance the biological effects of the ion beam. However, the mechanism of the increased cell death by a longitudinal magnetic field has not been clarified.

View Article and Find Full Text PDF

The differentiation of non-small cell lung cancer (NSCLC) and radiation pneumonitis (RP) is critically essential for selecting optimal clinical therapeutic strategies to manage post carbon-ion radiotherapy (CIRT) in patients with NSCLC. The aim of this study was to assess the ability of F-FDG PET/CT metabolic parameters and its textural image features to differentiate NSCLC from RP after CIRT to develop a differential diagnosis of malignancy and benign lesion. We retrospectively analyzed F-FDG PET/CT image data from 32 patients with histopathologically proven NSCLC who were scheduled to undergo CIRT and 31 patients diagnosed with RP after CIRT.

View Article and Find Full Text PDF

In this study, the survival fraction (SF) and relative biological effectiveness (RBE) of pancreatic cancer cells exposed to spread-out Bragg peak helium, carbon, oxygen, and neon ion beams are estimated from the measured microdosimetric spectra using a microdosimeter and the application of the microdosimetric kinetic (MK) model. To measure the microdosimetric spectra, a 3D mushroom silicon-on-insulator microdosimeter connected to low noise readout electronics (MicroPlus probe) was used. The parameters of the MK model were determined for pancreatic cancer cells such that the calculated SFs reproduced previously reported in vitro SF data.

View Article and Find Full Text PDF

Background/aim: The local control rate of chondrosarcomas treated with carbon-ion radiotherapy (CIRT) worsens as tumour size increases, possibly because of the intra-tumoural linear energy transfer (LET) distribution. This study aimed to evaluate the relationship between local recurrence and intra-tumoural LET distribution in chondrosarcomas treated with CIRT.

Patients And Methods: Thirty patients treated with CIRT for grade 2 chondrosarcoma were included.

View Article and Find Full Text PDF

Purpose: To perform the final quality assurance of our fluoroscopic-based markerless tumor tracking for gated carbon-ion pencil beam scanning (C-PBS) radiotherapy using a rotating gantry system, we evaluated the geometrical accuracy and tumor tracking accuracy using a moving chest phantom with simulated respiration.

Methods: The positions of the dynamic flat panel detector (DFPD) and x-ray tube are subject to changes due to gantry sag. To compensate for this, we generated a geometrical calibration table (gantry flex map) in 15° gantry angle steps by the bundle adjustment method.

View Article and Find Full Text PDF

Introduction: To investigate enhancement by 5-fluorouracil (5-FU) of the sensitivity of cancer cells to proton beam irradiation and clarify the differences in the responses of the 5-FU-treated cells to proton beam irradiation according to the position of the cells on the spread-out Bragg peak (SOBP).

Methods: OE21 human esophageal squamous cells were irradiated with a 235-MeV proton beam at four different positions on the SOBP. The effects of the irradiation plus 5-FU treatment on the cell survival were assessed by clonogenic assays and determination of the sensitizer enhancement ratio (SER).

View Article and Find Full Text PDF

Purpose: Phantoms for horizontal beam geometry can avoid issues in vertical-beam geometry, such as change in chamber depth due to evaporation, and defining the origin at the water surface. However, their thin entrance windows would deform when these phantoms are filled, which can change the chamber depth, as pointed out by The International Atomic Energy Agency (IAEA) TRS-398. Currently, few reports (Arib et al.

View Article and Find Full Text PDF

Background: Cellular responses to proton beam irradiation are not yet clearly understood, especially differences in the relative biological effectiveness (RBE) of high-energy proton beams depending on the position on the Spread-Out Bragg Peak (SOBP). Towards this end, we investigated the differences in the biological effect of a high-energy proton beam on the target cells placed at different positions on the SOBP, using two human esophageal cancer cell lines with differing radiosensitivities.

Methods: Two human esophageal cancer cell lines (OE21, KYSE450) with different radiosensitivities were irradiated with a 235-MeV proton beam at 4 different positions on the SOBP (position #1: At entry; position #2: At the proximal end of the SOBP; position #3: Center of the SOBP; position #4: At the distal end of the SOBP), and the cell survivals were assessed by the clonogenic assay.

View Article and Find Full Text PDF

Purpose: Taking advantage of the continuous, high-intensity beam of the cyclotron at the National Cancer Center Hospital East, we developed a continuous line scanning system (CLSS) prototype for prostate cancer in collaboration with Sumitomo Heavy Industries, Ltd (Tokyo, Japan).

Materials And Methods: The CLSS modulates dose distribution at each beam energy level by varying scanning speed while keeping the beam intensity constant through a beam-intensity control system and a rapid on/off beam-switching system. In addition, we developed a beam alignment system to improve the precision of the beam position.

View Article and Find Full Text PDF

Objective: To assess the feasibility of proton beam therapy for the patients with locally advanced non-small lung cancer.

Methods: The dosimetry was analyzed retrospectively to calculate the doses to organs at risk, such as the lung, heart, esophagus and spinal cord. A dosimetric comparison between proton beam therapy and dummy photon radiotherapy (three-dimensional conformal radiotherapy) plans was performed.

View Article and Find Full Text PDF

Full Monte Carlo (FMC) calculation of dose distribution has been recognized to have superior accuracy, compared with the pencil beam algorithm (PBA). However, since the FMC methods require long calculation time, it is difficult to apply them to routine treatment planning at present. In order to improve the situation, a simplified Monte Carlo (SMC) method has been introduced to the dose kernel calculation applicable to dose optimization procedure for the proton pencil beam scanning.

View Article and Find Full Text PDF

Proton therapy has the physical advantage of a Bragg peak that can provide a better dose distribution than conventional x-ray therapy. However, radiation exposure of normal tissues cannot be ignored because it is likely to increase the risk of secondary cancer. Evaluating secondary neutrons generated by the interaction of the proton beam with the treatment beam-line structure is necessary; thus, performing the optimization of radiation protection in proton therapy is required.

View Article and Find Full Text PDF

Calibrating the dose per monitor unit (DMU) for individual patients is important to deliver the prescribed dose in radiation therapy. We have developed a DMU calculation method combining measurement data and calculation with a simplified Monte Carlo method for the double scattering system in proton beam therapy at the National Cancer Center Hospital East in Japan. The DMU calculation method determines the clinical DMU by the multiplication of three factors: a beam spreading device factor FBSD, a patient-specific device factor FPSD, and a field-size correction factor FFS(A).

View Article and Find Full Text PDF

Background: Although several reports have shown that proton beam therapy (PBT) offers promise for patients with skull base cancer, little is known about the frequency of late toxicity in clinical practice when PBT is used for these patients. Here, we conducted a retrospective analysis to clarify the late toxicity profile of PBT in patients with malignancies of the nasal cavity, para-nasal sinuses, or involving the skull base.

Methods: Entry to this retrospective study was restricted to patients with (1) malignant tumors of the nasal cavity, para-nasal sinuses, or involving the skull base; (2) definitive or postoperative PBT (>50 GyE) from January 1999 through December 2008; and (3) more than 1 year of follow-up.

View Article and Find Full Text PDF

Accurate dose delivery is essential for the success of intensity-modulated radiation therapy (IMRT) for patients with head-and-neck (HN) cancer. Reproducibility of IMRT dose delivery to HN regions can be critically influenced by treatment-related changes in body contours. Moreover, some set-up margins may not be adaptable to positional uncertainties of HN structures at every treatment.

View Article and Find Full Text PDF

Objective: The objective of the study was to evaluate locoregional control after intensity-modulated radiotherapy for nasopharyngeal cancer using a target definition along with anatomical boundaries.

Methods: Forty patients with biopsy-proven squamous cell or non-keratinizing carcinoma of the nasopharynx who underwent intensity-modulated radiotherapy between April 2006 and November 2009 were reviewed. There were 10 females and 30 males with a median age of 48 years (range, 17-74 years).

View Article and Find Full Text PDF

A beam delivery system using a single-radius-beam-wobbling method has been used to form a conformal irradiation field for proton radiotherapy in Japan. A proton beam broadened by the beam-wobbling system provides a non-Gaussian distribution of projection angle different in two mutually orthogonal planes with a common beam central axis, at a certain position. However, the conventional initial beam model for dose calculations has been using an approximation of symmetric Gaussian angular distribution with the same variance in both planes (called here a Gaussian model with symmetric variance (GMSV)), instead of the accurate one.

View Article and Find Full Text PDF

Radiation therapy in patients is planned by using computed tomography (CT) images acquired before start of the treatment course. Here, tumor shrinkage or weight loss or both, which are common during the treatment course for patients with head-and-neck (H&N) cancer, causes unexpected differences from the plan, as well as dose uncertainty with the daily positional error of patients. For accurate clinical evaluation, it is essential to identify these anatomical changes and daily positional errors, as well as consequent dosimetric changes.

View Article and Find Full Text PDF

We analyzed the correlation between primary tumor response within 6 months after radiation therapy (RT) including proton beam therapy (PBT) and progression free survival rate (PFS) in patients with nasal cavity and paranasal sinus malignancies to clarify the impact of early radiological evaluation of treatment response on prognosis. Sixty-five patients treated between January 1998 and December 2008, and whose follow-up duration was more than 2 years were included. The Response Evaluation Criteria in Solid Tumors (version 1.

View Article and Find Full Text PDF

When in vivo proton dosimetry is performed with a metal-oxide semiconductor field-effect transistor (MOSFET) detector, the response of the detector depends strongly on the linear energy transfer. The present study reports a practical method to correct the MOSFET response for linear energy transfer dependence by using a simplified Monte Carlo dose calculation method (SMC). A depth-output curve for a mono-energetic proton beam in polyethylene was measured with the MOSFET detector.

View Article and Find Full Text PDF