Publications by authors named "Ryohei Kato"

Article Synopsis
  • * Diagnostic tests including echocardiography and Holter electrocardiography revealed a temporary high-grade atrioventricular block associated with the vomiting, leading to a diagnosis of situational syncope.
  • * The cat improved with antiemetic treatment, but later died from chronic kidney disease about 3 years after the diagnosis, marking the first reported instance of situational syncope due to vomiting in a cat.
View Article and Find Full Text PDF

The neutron beam in boron neutron capture therapy (BNCT) exhibits poor directionality and significantly decreasing neutron flux with increasing distance. Therefore, the treatment site must be close to the irradiation aperture. Some patients with head and neck cancer may benefit from a sitting-position setup.

View Article and Find Full Text PDF

Background: Accelerator-based boron neutron capture therapy (AB-BNCT) systems are becoming commercially available and are expected to be widely used in hospitals. To ensure the safety of BNCT, establishing a quality assurance (QA) program and properly managing the stability of the system are necessary. In particular, a high level of beam output stability is required to avoid accidents because beam output is a major factor in patient dose.

View Article and Find Full Text PDF
Article Synopsis
  • Hypouricemia, characterized by a low serum uric acid level (≤2 mg/dL), may increase the risk of death in hospitalized patients, but its predictive factors were previously unclear.
  • This study analyzed risk factors for hypouricemia in 618 patients at Yonago Medical Center using a Bayesian logistic regression model, identifying key independent risk factors.
  • Results indicated that febuxostat and other factors like amino acids in parenteral nutrition, TMP-SMX, emaciation, and low serum sodium levels significantly contributed to the likelihood of hypouricemia.
View Article and Find Full Text PDF

This study aims to evaluate the feasibility of using a commercially available boron neutron capture therapy (BNCT) dose calculation program (NeuCure Dose Engine) in terms of calculation accuracy and computation time. Treatment planning was simulated under the following calculation parameters: 1.5-5.

View Article and Find Full Text PDF

Synthetic genes for the two subunits of phenylalanyl-tRNA synthetase (PheRS) from wheat were expressed in . When each gene was induced individually, the α subunit with a cleavable 6 × His tag at the amino terminus was largely soluble, while the β subunit was almost completely insoluble. When the two subunits were co-expressed, a soluble fraction containing the two subunits were obtained.

View Article and Find Full Text PDF

Purpose: To analyze the respiratory-induced motion trajectories of each liver segment for hepatocellular carcinoma (HCC) to derive a more accurate internal margin and optimize treatment protocol selection.

Materials And Methods: Ten-phase-gated four-dimensional computed tomography (4DCT) scans of 14 patients with HCC were analyzed. For each patient, eight representative regions of interest (ROI) were delineated on each liver segment in all 10 phases.

View Article and Find Full Text PDF

. In proton beam therapy (PBT), metals in the patient body perturb the dose distribution, and their radioactivation may affect the dose distribution around the metal; however, the radioactivation effect has been not clarified with PBT. In this study, we aimed to evaluate the radioactivation effect of metal depending on proton energies and secondary neutrons with a clinical proton beam using a Monte Carlo (MC) simulation.

View Article and Find Full Text PDF

NeuCure® is the only accelerator-based boron neutron capture therapy (BNCT) system in the world with pharmaceutical approval. Until now, only flat collimators (FCs) on the patient side have been installed. However, in some cases of head and neck cancer patients, positioning the patient close enough to the collimator when using FCs was difficult.

View Article and Find Full Text PDF

Purpose: To investigate the dosimetric effect of six degrees of freedom (6DoF) couch top with rotational corrections in proton therapy (PT).

Methods: The water equivalent thickness (WET) was measured using a proton beam with a 6DoF couch top and patient immobilization base plate (PIBP) placed in front of a motorized water phantom. The accuracy verification was performed with the beam axis set perpendicular to the 6DoF couch top and tilted in 10° steps from 10° to 30°.

View Article and Find Full Text PDF

Background: Allergic bronchopulmonary mycosis (ABPM) occurs with fungi, other than . However, the clinical characteristics of ABPM caused by non- species are unspecified.

Methods: We retrospectively reviewed all patients with ABPM who visited to our hospital between April 2005 and December 2020.

View Article and Find Full Text PDF

Purpose: To identify the induced radionuclides produced from dental metals in proton beam therapy and investigate the accuracy of the Monte Carlo (MC) simulation by comparing the measured radioactivity.

Methods And Materials: Two dental metals of pure titanium and gold-silver-palladium alloy, commonly used in Japan, were used in this study. The dental metal placed at the center of Spread-out Bragg Peak was irradiated by 150-MeV passive scattering proton beam.

View Article and Find Full Text PDF

We aimed to evaluate dosimetric effects of ipsilateral shoulder position variations (ISPVs) in sitting-positioned boron neutron capture therapy (BNCT) for lower neck tumor. The ISPVs were simulated using deformed shoulder images that can simulate arbitrary shape. The dose-volume parameters for the tumor in the rotated shoulder plans considerably varied compared with that for the mucosa.

View Article and Find Full Text PDF

Aseptic meningitis is a rare immune-related adverse event (irAE), which occurs during treatment with immune checkpoint inhibitors (ICIs). This condition has non-specific symptoms and exhibits no clear signs on magnetic resonance imaging (MRI). There are only a few reports of aseptic meningitis caused by pembrolizumab treatment for non-small cell lung cancer (NSCLC).

View Article and Find Full Text PDF

The irradiation field of boron neutron capture therapy (BNCT) consists of multiple dose components including thermal, epithermal and fast neutron, and gamma. The objective of this work was to establish a methodology of dosimetric quality assurance (QA), using the most standard and reliable measurement methods, and to determine tolerance level for each QA measurement for a commercially available accelerator-based BNCT system. In order to establish a system of dosimetric QA suitable for BNCT, the following steps were taken.

View Article and Find Full Text PDF

The dosimetric effect of set-up error in boron neutron capture therapy (BNCT) for head and neck cancer remains unclear. In this study, we analyzed the tendency of dose error by treatment location when simulating the set-up error of patients. We also determined the tolerance level of the set-up error in BNCT for head and neck cancer.

View Article and Find Full Text PDF

(1R,2S)-Ethyl 1-amino-2-vinylcyclopropanecarboxylate (VCPA), is a key intermediate for anti-hepatitis C virus drugs. In this study, we developed an efficient manufacturing method of intermediate for (1R,2S)-VCPA by enzymatic desymmetrization of a malonate diester derivative. In synthesis scheme of VCPA (1S,2S)-1-(ethoxycarbonyl)-2-vinylcyclopropanecarboxylic acid (VCPME) is the monoester intermediate, which is converted from 2-vinylcyclopropane-1,1-dicarboxylate diethyl ester (VCPDE).

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the dosimetric properties of a newly developed thermoluminescent sheet-type dosimeter (TLD-sheet) for clinical proton beams.

Materials And Methods: The TLD-sheet is composed mainly of manganese doped lithium triborate, with a physical size and thickness of 150 mm × 150 mm and 0.15 mm respectively.

View Article and Find Full Text PDF

Thrombotic thrombocytopenic purpura (TTP) is rare complication resulting from adult-onset Still's disease (AOSD). We report the case of a 69-year-old Japanese man who initially presented with fever and joint pain and was diagnosed as having concurrent AOSD with TTP 1 month later. He had extremely high ferritin levels (32 696 ng/mL).

View Article and Find Full Text PDF
Article Synopsis
  • Pneumonia caused by Pneumocystis jirovecii (PCP) is a severe infection, and sulfamethoxazole-trimethoprim (SMX/TMP) is the primary drug used to prevent it, but side effects often necessitate dosage adjustments.
  • A study analyzed patients with rheumatic diseases receiving SMX/TMP and found that those on a standard dose had a higher rate of adverse events compared to those on a reduced dose, although the rate of drug discontinuation was similar between the two groups.
  • Importantly, patients on the reduced SMX/TMP dose did not develop PCP and experienced fewer adverse events, suggesting that a lower dosage is both effective
View Article and Find Full Text PDF

In this study, we aim to evaluate the comprehensive geometric accuracy of proton rotating gantries by performing an end-to-end test using a cone-shaped scintillator screen detector, known as XRV-124. The XRV-124 comprises a cone-shaped sheet-like scintillator and charge-coupled device camera that detects the scintillation light. First, the results of the Winston-Lutz and end-to-end XRV-124 tests performed on a conventional linear accelerator were compared to confirm the reliability of the XRV-124, and the snout position dependency of the geometric accuracy was evaluated for the proton rotating gantry as a pre-verification process.

View Article and Find Full Text PDF

This study aimed to evaluate the influence of change in respiratory motion on matchline (ML) and reduction of the effect by increasing ML levels of field matching technique in passive scattering proton therapy for esophageal cancer. To evaluate the influence of respiratory motion in terms of stability, we measured relative dose around ML using a respiratory motion phantom. The relative error was -0.

View Article and Find Full Text PDF

Installation of an accelerator-based boron neutron capture therapy (AB-BNCT) system was started in April 2014 at the Southern Tohoku BNCT Research Center (STBRC), and clinical trials began in January 2016. There are two treatment rooms, which have same specifications, and the beam quality equivalency was confirmed both rooms. Here, we describe the design and construction of the first hospital-based AB-BNCT facility in the world with multiple treatment rooms.

View Article and Find Full Text PDF

The use of a multi-layer ionization chamber, Zebra, in patient-specific quality assurance (QA) for proton depth dose distributions in a single-ring wobbling method is investigated. The depth dose distributions measured using Zebra are compared with those calculated using the treatment planning system (TPS), XiO-M, and measured using an ionization chamber with a motorized water phantom system. Because the TPS only provides point doses, the average doses are calculated using in-house software.

View Article and Find Full Text PDF