Publications by authors named "Ryo Mitsutake"

This is the first case report of a vitamin E-blended polyethylene liner fracture after total hip arthroplasty. Our case highlights the importance of considering a vitamin E-blended polyethylene liner fracture, the interposition of fracture fragments between the articulating surfaces after dislocation and blocked successful reduction.

View Article and Find Full Text PDF

Calcific tendinitis of the rectus femoris is rare. This clinical report presents five cases of management of calcific tendinitis of the rectus femoris. Between July 2018 and March 2023, five patients visited our institution, where they were treated for calcific tendinitis of the rectus femoris.

View Article and Find Full Text PDF

Accurate cup placement is critical to ensure satisfactory outcomes after total hip arthroplasty. Portable hip navigation systems are novel intraoperative guidance tools that achieve accurate cup placement in the supine position; however, accuracy in the lateral decubitus position is under debate. A new inertial portable navigation system has recently become available.

View Article and Find Full Text PDF

Background: Portable hip navigation systems have been developed to combine the accuracy of cup positioning by large console navigation systems with the ease of use and convenience of conventional surgical techniques. Although a novel augmented reality-based portable hip navigation system using a smartphone (AR navigation) has become available recently, no studies, to our knowledge, have compared commercially available AR navigation with the conventional technique. Additionally, no studies, except for those from designer-surgeon series, have demonstrated the results of AR navigation.

View Article and Find Full Text PDF

Background: Dislocation continues to be a common complication following total hip arthroplasty (THA). Although previous studies of computed simulation analysis investigated the range of motion (ROM), it is unclear whether the ROM before impingement simulated using computed tomography-based 3-dimensional simulation analysis (simulated ROM) is related to dislocation after THA. It is also unclear what angles are required in computed simulation analyses for stable hips after THA.

View Article and Find Full Text PDF

Background: Complications after total hip arthroplasty (THA) are frequently the consequence of malpositioned components or leg length discrepancy after surgery. Recently, a new version of a portable, accelerometer-based hip navigation system (New HipAlign) was made available with a change in the method of measuring cup abduction and the addition of a leg length measurement function. The purposes of this study were to investigate cup positioning and to examine the accuracy of leg length measurement with New HipAlign.

View Article and Find Full Text PDF

Background: During total hip arthroplasty (THA), the accurate placement of the femoral components is an important determinant of the success of the procedure. This study assessed the accuracy of cemented stem placement using a new angle-measuring instrument. The primary objective was to investigate the accuracy of the intraoperative measurements of cemented stem anteversion obtained using the angle-measuring instrument.

View Article and Find Full Text PDF

Background: Malposition of the acetabular component during total hip arthroplasty (THA) is associated with increased risk of dislocation, reduced range of motion, and accelerated wear. The purpose of this study is to compare cup positioning with a portable, accelerometer-based hip navigation system and conventional surgical technique.

Methods: In a prospective, randomized, clinical study, cups were implanted with a portable, accelerometer-based hip navigation system (navigation group; n = 55) or conventional technique (conventional group; n = 55).

View Article and Find Full Text PDF

Background: Dislocation continues to be a common complication following total hip arthroplasty (THA). A larger intraoperative range of motion (ROM) is believed to minimize dislocation risk, and intraoperative stability tests have been used to assess the ROM. However, it is not clear whether or not intraoperative stability tests can predict hip stability after THA.

View Article and Find Full Text PDF