Purpose: To evaluate the image quality of an ultrafast cone-beam computed tomography (CBCT) system-Varian HyperSight.
Methods And Materials: In this evaluation, 5 studies were performed to assess the image quality of HyperSight CBCT. First, a HyperSight CBCT image quality evaluation was performed and compared with Siemens simulation-CT and Varian TrueBeam CBCT.
We present the details of a novel ultra-short pulsed laser machining workstation that has been employed for high-throughput laser machining of small-scale mechanical property specimens. This system employs a six degrees of freedom hexapod positioning stage capable of macroscopic movements at high positional accuracy. We developed a methodology that uses quantitative image analysis to measure key parameters required to minimize the hexapod positioning and rotational error.
View Article and Find Full Text PDFBackground: Surface-guided radiation therapy (SGRT) systems have been widely installed and utilized on linear accelerators. However, the use of SGRT with proton therapy is still a newly developing field, and published reports are currently very limited.
Purpose: To assess the clinical application and alignment agreement of SGRT with CT-on-rails (CTOR) and kV-2D image-guided radiation therapy (IGRT) for breast treatment using proton therapy.
Background: Optimal management after posterior cruciate ligament (PCL) injury remains an active area of research, as reconstruction is technically challenging and poses unique risks in the posterior knee. Studies have reported variable rates of complications.
Purpose: To describe the rates of readmission, emergency department (ED) visits, and postoperative complications within 90 days of isolated PCL reconstruction (PCLR) in a large, national cohort to better understand the perioperative variables that influence a practitioner's decision of whether to pursue operative versus nonoperative management.
Plast Reconstr Surg Glob Open
November 2023
Purpose: To evaluate and characterize the overall clinical functionality and workflow of the newly released Varian Identify system (version 2.3).
Methods: Three technologies included in the Varian Identify system were evaluated: patient biometric authentication, treatment accessory device identification, and surface-guided radiation therapy (SGRT) function.
Background: It has been shown that a significant reduction of mean heart dose and left anterior descending artery (LAD) dose can be achieved through the use of DIBH for left breast radiation therapy. Surface-guided DIBH has been widely adopted during the last decade, and there are mainly three commercially available SGRT systems. The reports of the performance of a newly released SGRT system for DIBH application are currently very limited.
View Article and Find Full Text PDFPurpose: Estrogen therapy is associated with an increased risk of venous thromboembolism (VTE). A large proportion of transfeminine patients use estrogen therapy before undergoing gender-affirming surgery. Many surgeons implement the discontinuation of hormone therapy before surgery.
View Article and Find Full Text PDFPurpose There are several studies suggesting a correlation between image-guided radiotherapy (IGRT) setup errors and body mass index (BMI). However, abdominal fat content has visceral and subcutaneous components, which may affect setup errors differently. This study aims to analyze a potential workflow for characterizing adipose content and distribution in the region of the target that would allow a quickly calculated metric of abdominal fat content to stratify these patients.
View Article and Find Full Text PDFVarious positioning techniques have been described for the osteosynthesis of olecranon fractures, each with their own pros and cons. The supine position is time-efficient and better suited in a polytrauma setting but frequently requires an assistant to maintain optimal limb positioning. Also, adequate fluoroscopic imaging is not possible without moving the operative extremity outside the sterile field.
View Article and Find Full Text PDFPurpose: To characterize potential dose to the fetus for all modes of delivery (dynamic adaptive aperture, static adaptive aperture, and no adaptive aperture) for the Mevion S250i Proton Therapy System with HYPERSCAN and compare the findings with those of other available proton systems.
Materials And Methods: Fetal dose measurements were performed for all three modes of dose delivery on the Mevion S250i Proton therapy system with HYPERSCAN (static aperture, dynamic aperture and uncollimated). Standard treatment plans were created in RayStation for a left-sided brain lesion treated with a vertex field, a left lateral field, and a posterior field.
An important source of uncertainty in proton therapy treatment planning is the assignment of stopping-power ratio (SPR) from CT data. A commercial product is now available that creates an SPR map directly from dual-energy CT (DECT). This paper investigates the use of this new product in proton treatment planning and compares the results to the current method of assigning SPR based on a single-energy CT (SECT).
View Article and Find Full Text PDFPurpose: To establish the rate of avascular necrosis after hip reconstruction surgery in children with cerebral palsy and to identify risk factors that influence the development of avascular necrosis in this population.
Methods: An institutional review board-approved retrospective review was conducted on children with cerebral palsy who underwent hip containment surgery at a single institution. Radiographs were evaluated at three time points.
Purpose: In this study, patient setup accuracy was compared between surface guidance and tattoo markers for radiation therapy treatment sites of the thorax, abdomen and pelvis.
Methods And Materials: A total of 608 setups performed on 59 patients using both surface-guided and tattoo-based patient setups were analyzed. During treatment setup, patients were aligned to room lasers using their tattoos, and then the six-degree-of-freedom (6DOF) surface-guided offsets were calculated and recorded using AlignRT system.
Background: Over 1.4 million US adults identify as transgender when gender identity differs from the sex assigned at birth [1]. Although transgender patients face adverse health outcomes, they remain an understudied population [2].
View Article and Find Full Text PDFPurpose: Use of standard-of-care radiation therapy boluses may result in air-gaps between the target surface and bolus, as they may not adequately conform to each patient's unique topography. Such air-gaps can be particularly problematic in cases of superficial pelvic tumor radiation, as the density variation may result in the radiation delivered to the target site being inconsistent with the prescribed dose. To increase bolus fit and thereby dose predictability and homogeneity, we designed and produced a custom silicone bolus for evaluation against the clinical standard.
View Article and Find Full Text PDFPurpose: A modern radiation oncology electronic medical record (RO-EMR) system represents a sophisticated human-computer interface with the potential to reduce human driven errors and improve patient safety. As the RO-EMR becomes an integral part of clinical processes, it may be advantageous to analyze learning opportunities (LO) based on their relationship with the RO-EMR. This work reviews one institution's documented LO to: (1) study their relationship with the RO-EMR workflow, (2) identify best opportunities to improve RO-EMR workflow design, and (3) identify current RO-EMR workflow challenges.
View Article and Find Full Text PDFBackground: Inpatient addiction consult services (ACS) lower barriers to accessing medications for opioid use disorder (MOUD), however not every patient recommended for MOUD links to outpatient care. We hypothesized that fewer days between discharge date and outpatient appointment date was associated with improved linkage to buprenorphine treatment among patients evaluated by an ACS.
Methods: We extracted appointment and demographic data from electronic medical records and conducted retrospective chart review of adults diagnosed with opioid use disorder (OUD) evaluated by an ACS in Boston, MA between July 2015 and August 2017.
Perioperative bronchospasm is a common challenge to anesthetic care. The timely delivery of inhaled medications can be challenging, particularly in pediatric patients and in locations where dedicated resources and respiratory support teams are limited. The delivery of nebulized medication to an intubated patient in the operating room can be difficult.
View Article and Find Full Text PDFGenetic studies of bone mineral density (BMD) largely have been conducted in European populations. We therefore conducted a meta-analysis of six independent African ancestry cohorts to determine whether previously reported BMD loci identified in European populations were transferable to African ancestry populations. We included nearly 5000 individuals with both genetic data and assessments of BMD.
View Article and Find Full Text PDFCompend Contin Educ Dent
March 2020