Publications by authors named "Ryan L Shelton"

Objective: To determine the feasibility of detecting and differentiating middle ear effusions (MEEs) using an optical coherence tomography (OCT) otoscope.

Study Design: Cross-sectional study.

Setting: US tertiary care children's hospital.

View Article and Find Full Text PDF

Objective: A novel hearing-aid scheme using magnetomotive nanoparticles (MNPs) as transducers in the tympanic membrane (TM) is proposed, aiming to noninvasively and directly induce a modulated vibration on the TM.

Methods: In this feasibility study, iron oxide (FeO) nanoparticles were applied on ex vivo rat TM tissues and allowed to diffuse over ∼2 h. Subsequently, magnetic force was exerted on the MNP-laden TM via a programmable electromagnetic solenoid to induce the magnetomotion.

View Article and Find Full Text PDF

In an institutional review board-approved study, 25 pediatric subjects diagnosed with chronic or recurrent otitis media were observed over a period of six months with optical coherence tomography (OCT). Subjects were followed throughout their treatment at the initial patient evaluation and preoperative consultation, surgery (intraoperative imaging), and postoperative follow-up, followed by an additional six months of records-based observation. At each time point, the tympanic membrane (at the light reflex region) and directly adjacent middle-ear cavity were observed in vivo with a handheld OCT probe and portable system.

View Article and Find Full Text PDF

Otitis media is the leading cause of hearing loss in children. It is commonly associated with fluid in the ear, which can result in up to 45 dB of hearing loss for extended periods of time during a child's most important developmental years. Accurate assessment of middle ear effusions is an important part of understanding otitis media.

View Article and Find Full Text PDF

Influence of diabetes mellitus (DM) and diabetic retinopathy (DR) on parafoveal retinal thicknesses and their ratios was evaluated. Six retinal layer boundaries were segmented from spectral-domain optical coherence tomography images using open-source software. Five study groups: (1) healthy control (HC) subjects, and subjects with (2) controlled DM, (3) uncontrolled DM, (4) controlled DR and (5) uncontrolled DR, were identified.

View Article and Find Full Text PDF
Article Synopsis
  • The biomechanical response of skin is influenced by its viscoelastic properties and fluid distribution, reflecting both local and systemic physiological conditions.
  • Traditional clinical diagnoses rely on visual inspection, but there's a need for more objective methods for tissue assessment.
  • This study explores the use of optical coherence tomography (OCT) to characterize the biomechanical properties of human skin, revealing significant differences linked to age and skin deformation, showcasing its potential for medical evaluations.
View Article and Find Full Text PDF

We report on the development of a low-cost hand-held low-coherence interferometric imaging system based on the principle of linear optical coherence tomography (Linear OCT), a technique which was first proposed in the early 2000s as a simpler alternative to the conventional time-domain and Fourier-domain OCT. A bench-top implementation of the proposed technique is first presented and validated. The axial resolution, SNR, and sensitivity roll-of of the system was estimated to be 5.

View Article and Find Full Text PDF

We investigate and demonstrate the feasibility of using a combined Raman scattering (RS) spectroscopy and low-coherence interferometry (LCI) probe to differentiate microbial pathogens and improve our diagnostic ability of ear infections [otitis media (OM)]. While the RS probe provides noninvasive molecular information to identify and differentiate infectious microorganisms, the LCI probe helps to identify depth-resolved structural information as well as to guide and monitor positioning of the Raman spectroscopy beam for relatively longer signal acquisition times. A series of phantom studies, including the use of human middle ear effusion samples, were performed to mimic the conditions of in vivo investigations.

View Article and Find Full Text PDF

We performed ratiometric analysis of retinal optical coherence tomography images for the first time in multiple sclerosis (MS) patients. The ratiometric analysis identified differences in several retinal layer thickness ratios in the cohort of MS subjects without a history of optic neuritis (ON) compared to healthy control (HC) subjects, and there was no difference in standard retinal nerve fiber layer thickness (RNFLT). The difference in such ratios between HC subjects and those with mild MS-disability, without a difference in RNFLT, further suggests the possibility of using layer ratiometric analysis for detecting early retinal changes in MS.

View Article and Find Full Text PDF

The thickness of the human tympanic membrane (TM) is known to vary considerably across different regions of the TM. Quantitative determination of the thickness distribution and mapping of the TM is of significant importance in hearing research, particularly in mathematical modeling of middle-ear dynamics. Change in TM thickness is also associated with several middle-ear pathologies.

View Article and Find Full Text PDF

Although retinal vasculitis is common in multiple sclerosis (MS), it is not known if MS is associated with quantitative abnormalities in retinal blood vessels (BVs). Optical coherence tomography (OCT) is suitable for examining the integrity of the anterior visual pathways in MS. In this paper we have compared the size and number of retinal blood vessels in patients with MS, with and without a history of optic neuritis (ON), and control subjects from the cross-sectional retinal images from OCT.

View Article and Find Full Text PDF

Eustachian tube dysfunction can cause fluid to collect within the middle ear cavity and form a middle ear effusion (MEE). MEEs can persist for weeks or months and cause hearing loss as well as speech and learning delays in young children. The ability of a physician to accurately identify and characterize the middle ear for signs of fluid and/or infection is crucial to provide the most appropriate treatment for the patient.

View Article and Find Full Text PDF

Background: Evaluation of lymph node (LN) status is an important factor for detecting metastasis and thereby staging breast cancer. Currently utilized clinical techniques involve the surgical disruption and resection of lymphatic structure, whether nodes or axillary contents, for histological examination. While reasonably effective at detection of macrometastasis, the majority of the resected lymph nodes are histologically negative.

View Article and Find Full Text PDF

Hand-held optical coherence tomography (OCT) imaging probes offer flexibility to image sites that are otherwise challenging to access. While the majority of hand-held imaging probes utilize galvanometer- or MEMS-scanning mirrors to transversely scan the imaging beam, these probes are commonly limited to lateral fields-of-view (FOV) of only a few millimeters. The use of a freehand manually scanned probe can significantly increase the lateral FOV.

View Article and Find Full Text PDF

Background: Otitis media (OM), an infection in the middle ear, is extremely common in the pediatric population. Current gold-standard methods for diagnosis include otoscopy for visualizing the surface features of the tympanic membrane (TM) and making qualitative assessments to determine middle ear content. OM typically presents as an acute infection, but can progress to chronic OM, and after numerous infections and antibiotic treatments over the course of many months, this disease is often treated by surgically inserting small tubes in the TM to relieve pressure, enable drainage, and provide aeration to the middle ear.

View Article and Find Full Text PDF

Objective/hypothesis: In this study, optical coherence tomography (OCT) is used to noninvasively and quantitatively determine tympanic membrane (TM) thickness and the presence and thickness of any middle-ear biofilm located behind the TM. These new metrics offer the potential to differentiate normal, acute, and chronic otitis media (OM) infections in pediatric subjects.

Study Design: Case series with comparison group.

View Article and Find Full Text PDF

We have recently harnessed transient absorption, a resonant two-photon process, for ultrahigh resolution photoacoustic microscopy, achieving nearly an order of magnitude improvement in axial resolution. The axial resolution is optically constrained due to the two-photon process unlike traditional photoacoustic microscopy where the axial resolution is inversely proportional to the frequency bandwidth of the detector. As a resonant process, the arrival time of the two photons need not be instantaneous.

View Article and Find Full Text PDF

Currently, optical coherence tomography (OCT), is not capable of obtaining molecular information often crucial for identification of disease. To enable molecular imaging with OCT, we have further developed a technique that harnesses transient changes in light absorption in the sample to garner molecular information. A Fourier-domain Pump-Probe OCT (PPOCT) system utilizing a 532 nm pump and 830 nm probe has been developed for imaging hemoglobin.

View Article and Find Full Text PDF

A four dimensional data set of the cardiac cycle of a zebrafish embryo was acquired using postacquisition synchronization of real time photoacoustic b-scans. Utilizing an off-axis photoacoustic microscopy (OA-PAM) setup, we have expanded upon our previous work with OA-PAM to develop a system that can sustain 100 kHz line rates while demodulating the bipolar photoacoustic signal in real-time. Real-time processing was accomplished by quadrature demodulation on a Field Programmable Gate Array (FPGA) in line with the signal digitizer.

View Article and Find Full Text PDF

Photoacoustic microscopy (PAM) is an imaging modality well suited to mapping vasculature and other strong absorbers in tissue. However, one of the primary drawbacks to PAM when used for high-resolution imaging is the relatively poor axial resolution due to the inverse dependence on the transducer bandwidth. While submicron lateral resolution PAM can be achieved by tightly focusing the excitation light, the axial resolution is fundamentally limited to 10s of microns for typical transducer frequencies.

View Article and Find Full Text PDF

Optical coherence tomography (OCT) has long been used as a diagnostic tool in the field of ophthalmology. The ability to observe microstructural changes in the tissues of the eye has proved very effective in diagnosing ocular disease. However, this technology has yet to be introduced into the primary care office, where indications of disease are first encountered.

View Article and Find Full Text PDF

Vibratory measurements of the structures of the ear are key to understanding much of the pathology in mouse models of hearing loss. Unfortunately the high-speed sampling required to interrogate the high end of the mouse hearing spectrum is beyond the reach of most optical coherence tomography (OCT) systems. To address this issue, we have developed an algorithm that enables phase-sensitive OCT measurements over the full range of the mouse hearing spectrum (4-90 kHz).

View Article and Find Full Text PDF

Human hearing loss often occurs as a result of damage or malformations to the functional soft tissues within the cochlea, but these changes are not appreciable with current medical imaging modalities. We sought to determine whether optical coherence tomography (OCT) could assess the soft tissue structures relevant to hearing using mouse models. We imaged excised cochleae with an altered tectorial membrane and during normal development.

View Article and Find Full Text PDF

We have developed a novel, hybrid imaging modality, Transient Absorption Ultrasonic Microscopy (TAUM), which takes advantage of the optical nonlinearities afforded by transient absorption to achieve ultrahigh-resolution photoacoustic microscopy. The theoretical point spread function for TAUM is functionally equivalent to confocal and two-photon fluorescence microscopy, potentially enabling cellular/subcellular photoacoustic imaging. A prototype TAUM system was designed, built, and used to image a cross-section through several capillaries in the excised cheek pouch of a Syrian Hamster.

View Article and Find Full Text PDF

We report the development of a two-color Fourier domain Pump-Probe Optical Coherence Tomography (PPOCT) system. Tissue phantom experiments to characterize the system performance demonstrated imaging depths in excess of 725 microm, nearly comparable to the base Optical Coherence Tomography system. PPOCT A-line rates were also demonstrated in excess of 1 kHz.

View Article and Find Full Text PDF