Publications by authors named "Ryan Chamberlain"

Objectives: Pulmonary parametric response map (PRM) was proposed for quantitative densitometric phenotypization of chronic obstructive pulmonary disease. However, little is known about this technique in healthy subjects. The purpose of this study was to describe the normal spectrum of densitometric classification of pulmonary PRM in a group of healthy adults.

View Article and Find Full Text PDF

Parametric response mapping (PRM) of inspiration and expiration computed tomography (CT) images improves the radiological phenotyping of chronic obstructive pulmonary disease (COPD). PRM classifies individual voxels of lung parenchyma as normal, emphysematous, or nonemphysematous air trapping. In this study, bias and noise characteristics of the PRM methodology to CT and clinical procedures were evaluated to determine best practices for this quantitative technique.

View Article and Find Full Text PDF

Rationale And Objectives: The longitudinal relationship between regional air trapping and emphysema remains unexplored. We have sought to demonstrate the utility of parametric response mapping (PRM), a computed tomography (CT)-based biomarker, for monitoring regional disease progression in chronic obstructive pulmonary disease (COPD) patients, linking expiratory- and inspiratory-based CT metrics over time.

Materials And Methods: Inspiratory and expiratory lung CT scans were acquired from 89 COPD subjects with varying Global Initiative for Chronic Obstructive Lung Disease (GOLD) status at 30 days (n = 13) or 1 year (n = 76) from baseline as part of the Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS) clinical trial.

View Article and Find Full Text PDF

Imaging biomarkers capable of early quantification of tumor response to therapy would provide an opportunity to individualize patient care. Image registration of longitudinal scans provides a method of detecting treatment associated changes within heterogeneous tumors by monitoring alterations in the quantitative value of individual voxels over time, which is unattainable by traditional volumetric-based histogram methods. The concepts involved in the use of image registration for tracking and quantifying breast cancer treatment response using parametric response mapping (PRM), a voxel-based analysis of diffusion-weighted magnetic resonance imaging (DW-MRI) scans, are presented.

View Article and Find Full Text PDF

Purpose: Iron-oxide nanoparticles (IONPs) have proven utility as contrast agents in many MRI applications. Previous quantitative IONP mapping has been performed using mainly T2 * mapping methods. However, in applications requiring high IONP concentrations, such as magnetic nanoparticles based thermal therapies, conventional pulse sequences are unable to map T2 * because the signal decays too rapidly.

View Article and Find Full Text PDF

Hypertension has been recognized as an independent risk factor for intracerebral hemorrhage (ICH). The objective of this study was to assess the effect of chronically elevated blood pressure on amount of hematoma in a rat model of ICH. A total of 46 rats were divided into two groups-normotensive group (n = 18) and spontaneously hypertensive group (n = 28).

View Article and Find Full Text PDF

In our program to develop non-invasive magnetic resonance imaging (MRI) methods for the diagnosis of Alzheimer's disease (AD), we have synthesized antibody-conjugated, superparamagnetic iron oxide nanoparticles (SPIONs) for use as an in vivo agent for MRI detection of amyloid-β plaques in AD. Here we report studies in AβPP/PS1 transgenic mice, which demonstrate the ability of novel anti-AβPP conjugated SPIONs to penetrate the blood-brain barrier to act as a contrast agent for MR imaging of plaques. The conspicuity of the plaques increased from an average Z-score of 5.

View Article and Find Full Text PDF

Recent advances in nanotechnology have allowed for the effective use of iron oxide nanoparticles (IONPs) for cancer imaging and therapy. When activated by an alternating magnetic field (AMF), intra-tumoral IONPs have been effective at controlling tumor growth in rodent models. To accurately plan and assess IONP-based therapies in clinical patients, noninvasive and quantitative imaging technique for the assessment of IONP uptake and biodistribution will be necessary.

View Article and Find Full Text PDF

The relevance of cerebral amyloid angiopathy (CAA) to the pathogenesis of Alzheimer disease (AD) and dementia in general emphasizes the importance of developing novel targeting approaches for detecting and treating cerebrovascular amyloid (CVA) deposits. We developed a nanoparticle-based technology that uses a monoclonal antibody against fibrillar human amyloid-β42 that is surface coated onto a functionalized phospholipid monolayer. We demonstrate that this conjugated nanoparticle binds to CVA deposits in arterioles of AD transgenic mice (Tg2576) after infusion into the external carotid artery using 3 different approaches.

View Article and Find Full Text PDF

Ultrashort echo-time imaging and sweep imaging with Fourier transformation are powerful techniques developed for imaging ultrashort T(2) species. However, it can be challenging to implement them on standard clinical MRI systems due to demanding hardware requirements. In this article, the limits of what is possible in terms of the minimum echo-time and repetition time with 3D radial gradient-echo sequences, which can be readily implemented on a standard clinical scanner, are investigated.

View Article and Find Full Text PDF

A major objective in the treatment of Alzheimer's disease is amyloid plaque reduction. Transgenic mouse models of Alzheimer's disease provide a controlled and consistent environment for studying amyloid plaque deposition in Alzheimer's disease. Magnetic resonance imaging is an attractive tool for longitudinal studies because it offers non-invasive monitoring of amyloid plaques.

View Article and Find Full Text PDF

We describe a fundamentally different approach to MRI referred to as SWIFT (sweep imaging with Fourier transformation). SWIFT exploits time-shared RF excitation and signal acquisition, allowing capture of signal from spins with extremely short transverse relaxation time, T(2)*. The MR signal is acquired in gaps inserted into a broadband frequency-swept excitation pulse, which results in acquisition delays of only 1 - 2 microseconds.

View Article and Find Full Text PDF

Simultaneous electrophysiological and functional magnetic resonance imaging measurements of animal models of epilepsy are methodologically challenging, but essential to better understand abnormal brain activity and hemodynamics during seizures. In this study, functional magnetic resonance imaging of medetomidine-sedated rats was performed using novel rapid acquisition by sequential excitation and refocusing (RASER) fast imaging pulse sequence and simultaneous local field potential measurements during kainic acid-induced seizures. The image distortion caused by the hippocampal-measuring electrode was clearly seen in echo planar imaging images, whereas no artifact was seen in RASER images.

View Article and Find Full Text PDF

One of the hallmark pathologies of Alzheimer's disease (AD) is amyloid plaque deposition. Plaques appear hypointense on T(2)-weighted and T(2)*-weighted MR images probably due to the presence of endogenous iron, but no quantitative comparison of various imaging techniques has been reported. We estimated the T(1), T(2), T(2)*, and proton density values of cortical plaques and normal cortical tissue and analyzed the plaque contrast generated by a collection of T(2)-weighted, T(2)*-weighted, and susceptibility-weighted imaging (SWI) methods in ex vivo transgenic mouse specimens.

View Article and Find Full Text PDF

A new MRI method is described to acquire a T(2)-weighted image from a single slice in a single shot. The technique is based on rapid acquisition by sequential excitation and refocusing (RASER). RASER avoids relaxation-related blurring because the magnetization is sequentially refocused in a manner that effectively creates a series of spin echoes with a constant echo time.

View Article and Find Full Text PDF