Purpose: To study the effect of different vertical angulations on the ability to radiographically assess vertical marginal discrepancies of lithium disilicate crowns.
Materials And Methods: Twenty-one lithium disilicate crowns were fabricated for three different prepared natural teeth: incisor, canine, and premolar. Vertical marginal discrepancies ranging from 0 to 300 µm were intentionally created.
The isolation of viruses from complex biological samples is essential for creating sensitive bioassays that assess the efficacy and safety of viral therapeutics and vaccines, which have played a critical role during the COVID-19 pandemic. However, existing methods of viral isolation are time-consuming and labor-intensive due to the multiple processing steps required, resulting in low yields. Here, we introduce the rapid, efficient, and high-resolution acoustofluidic isolation of viruses from complex biological samples via Bessel beam excitation separation technology (BEST).
View Article and Find Full Text PDFObjectives: The purpose of the study was to report a step-by-step process of creating artificial caries typodont teeth and to determine the perception and efficacy of their use in preclinical operative training.
Methods: Artificial caries material comprised of commercially available hide glue and chocolate powder for more realistic coloring was embedded into the distolingual of #9 ModuPRO plastic typodont teeth. First-year dental students having no clinical experience in excavating Class III cavity preparations were divided into two groups.
While mesenchymal stem cells (MSCs) have gained enormous attention due to their unique properties of self-renewal, colony formation, and differentiation potential, the MSC secretome has become attractive due to its roles in immunomodulation, anti-inflammatory activity, angiogenesis, and anti-apoptosis. However, the precise stimulation and efficient production of the MSC secretome for therapeutic applications are challenging problems to solve. Here, we report on Acoustofluidic Interfaces for the Mechanobiological Secretome of MSCs: AIMS.
View Article and Find Full Text PDFThe alteration of the hydrostatic pressure gradient in the human body has been associated with changes in human physiology, including abnormal blood flow, syncope, and visual impairment. The focus of this study was to evaluate changes in the resonant frequency of a wearable electromagnetic resonant skin patch sensor during simulated physiological changes observed in aerospace applications. Simulated microgravity was induced in eight healthy human participants (n = 8), and the implementation of lower body negative pressure (LBNP) countermeasures was induced in four healthy human participants (n = 4).
View Article and Find Full Text PDFHigh-precision isolation of small extracellular vesicles (sEVs) from biofluids is essential toward developing next-generation liquid biopsies and regenerative therapies. However, current methods of sEV separation require specialized equipment and time-consuming protocols and have difficulties producing highly pure subpopulations of sEVs. Here, we present Acoustic Nanoscale Separation via Wave-pillar Excitation Resonance (ANSWER), which allows single-step, rapid (<10 min), high-purity (>96% small exosomes, >80% exomeres) fractionation of sEV subpopulations from biofluids without the need for any sample preprocessing.
View Article and Find Full Text PDFModern wearable devices show promising results in terms of detecting vital bodily signs from the wrist. However, there remains a considerable need for a device that can conform to the human body's variable geometry to accurately detect those vital signs and to understand health better. Flexible radio frequency (RF) resonators are well poised to address this need by providing conformable bio-interfaces suitable for different anatomical locations.
View Article and Find Full Text PDFCOVID-19, an infectious pulmonary disease caused by the SARS-CoV-2 virus, has profoundly impacted the world, motivating researchers across a broad spectrum of academic disciplines to gain a deeper understanding and develop effective therapies to this disease. This article presents an engineering perspective on how microfluidic technologies may address some of the challenges presented by COVID-19 and other pulmonary diseases. In particular, this article highlights urgent needs in pulmonary medicine, with an emphasis on technological innovations in the microfluidic manipulation of particles and fluids, and how these innovations may contribute to the study, diagnosis, and therapy of pulmonary diseases.
View Article and Find Full Text PDFAfter half a billion years of evolution, arthropods have developed sophisticated compound eyes with extraordinary visual capabilities that have inspired the development of artificial compound eyes. However, the limited 2D nature of most traditional fabrication techniques makes it challenging to directly replicate these natural systems. Here, we present a biomimetic apposition compound eye fabricated using a microfluidic-assisted 3D-printing technique.
View Article and Find Full Text PDFBiosens Bioelectron
January 2022
Alzheimer's disease (AD) is a progressive and irreversible neurodegenerative brain disorder that affects tens of millions of older adults worldwide and has significant economic and societal impacts. Despite its prevalence and severity, early diagnosis of AD remains a considerable challenge. Here we report an integrated acoustofluidics-based diagnostic system (ADx), which combines triple functions of acoustics, microfluidics, and orthogonal biosensors for clinically accurate, sensitive, and rapid detection of AD biomarkers from human plasma.
View Article and Find Full Text PDFImplant-associated bacterial infections significantly impair the integration between titanium and soft tissues. Traditional antibacterial modifications of titanium implants are able to eliminate bacteria, but the resulting pro-inflammatory reactions are usually ignored, which still poses potential risks to human bodies. Here, a dual drug-loading system on titanium has been developed via the adhesion of a catechol motif-modified methacrylated gelatin hydrogel onto TiO nanotubes.
View Article and Find Full Text PDFTraumatic brain injury (TBI) is a global cause of morbidity and mortality. Initial management and risk stratification of patients with TBI is made difficult by the relative insensitivity of screening radiographic studies as well as by the absence of a widely available, noninvasive diagnostic biomarker. In particular, a blood-based biomarker assay could provide a quick and minimally invasive process to stratify risk and guide early management strategies in patients with mild TBI (mTBI).
View Article and Find Full Text PDFSteep delay discounting is characterized by a preference for small immediate outcomes relative to larger delayed outcomes and is predictive of drug abuse, risky sexual behaviors, and other maladaptive behaviors. Nancy M. Petry was a pioneer in delay discounting research who demonstrated that people discount delayed monetary gains less steeply than they discount substances with abuse liability.
View Article and Find Full Text PDFElevated intracranial fluid volume can drive intracranial pressure increases, which can potentially result in numerous neurological complications or death. This study's focus was to develop a passive skin patch sensor for the head that would non-invasively measure cranial fluid volume shifts. The sensor consists of a single baseline component configured into a rectangular planar spiral with a self-resonant frequency response when impinged upon by external radio frequency sweeps.
View Article and Find Full Text PDFBackground: Peripheral artery disease (PAD) is a vascular disease caused by atherosclerosis, resulting in decreased blood flow to the lower extremities. The ankle-brachial index (ABI) is a standard PAD diagnostic test but only identifies reduced blood flow based on blood pressure differences. The early signs of PAD manifest themselves not only at a clinical level but also at an elemental and biochemical level.
View Article and Find Full Text PDFObjective: The objectives of this study were to design and develop an open-circuit electromagnetic resonant skin patch sensor, characterize the fluid volume and resonant frequency relationship, and investigate the sensor's ability to measure limb hemodynamics and pulse volume waveform features.
Methods: The skin patch was designed from an open-circuit electromagnetic resonant sensor comprised of a single baseline trace of copper configured into a square planar spiral which had a self-resonating response when excited by an external radio frequency sweep. Using a human arm phantom with a realistic vascular network, the sensor's performance to measure limb hemodynamics was evaluated.
Peripheral artery disease (PAD) is a condition caused by atherosclerotic blockages in the arteries supplying the lower limbs and is characterized by ischemia of the leg, progressive myopathy, and increased risk of limb loss. The affected leg muscles undergo significant changes of their biochemistry and metabolism including variations in the levels of many key proteins, lipids, and nucleotides. The mechanisms behind these changes are poorly understood.
View Article and Find Full Text PDFThe objective of this investigation was to determine and decrease dye leakage of fast-setting mineral trioxide aggregate (FSMTA). Specimens using differing setting times or concentrations of calcium sulfate modified FSMTA were assessed for dye penetration. Based on the results, no statistical difference was found in the dye leakage of FSMTA compared with regular mineral trioxide aggregate (MTA).
View Article and Find Full Text PDF