Background A curve-shaped compression paddle could reduce the pain experienced by some women at breast cancer screening. Purpose To compare curved and standard compression systems in terms of pain experience and image quality in mammography screening. Materials and Methods In this randomized controlled trial conducted between October 2021 and February 2022, participants screened at three screening sites in the Netherlands were randomized to either a curved-paddle or sham-paddle group.
View Article and Find Full Text PDFObjective: To evaluate the diagnostic accuracy of supplemental 3D automated breast ultrasound (ABUS) in the diagnostic work-up of BI-RADS 0 recalls. We hypothesized that 3D ABUS may reduce the benign biopsy rate.
Materials And Methods: In this prospective multicenter diagnostic study, screening participants recalled after a BI-RADS 0 result underwent bilateral 3D ABUS supplemental to usual care: digital breast tomosynthesis (DBT) and targeted hand-held ultrasound (HHUS).
Objectives: Supplemental MRI screening improves early breast cancer detection and reduces interval cancers in women with extremely dense breasts in a cost-effective way. Recently, the European Society of Breast Imaging recommended offering MRI screening to women with extremely dense breasts, but the debate on whether to implement it in breast cancer screening programs is ongoing. Insight into the participant experience and willingness to re-attend is important for this discussion.
View Article and Find Full Text PDFObjectives: Background parenchymal enhancement (BPE) on dynamic contrast-enhanced MRI (DCE-MRI) as rated by radiologists is subject to inter- and intrareader variability. We aim to automate BPE category from DCE-MRI.
Methods: This study represents a secondary analysis of the Dense Tissue and Early Breast Neoplasm Screening trial.
Women with a personal history of breast cancer (PHBC) are at an increased risk of either a local recurrence or a new primary breast cancer. Thus, surveillance is essential for the detection of recurrent disease at the earliest possible stage, allowing for prompt treatment, and potentially improving overall survival. Nowadays, mammography follow-up is the only surveillance imaging technique recommended by international guidelines.
View Article and Find Full Text PDFObjectives: To perform a survey among members of the European Society of Breast Imaging (EUSOBI) regarding the use of contrast-enhanced mammography (CEM).
Methods: A panel of nine board-certified radiologists developed a 29-item online questionnaire, distributed to all EUSOBI members (inside and outside Europe) from January 25 to March 10, 2023. CEM implementation, examination protocols, reporting strategies, and current and future CEM indications were investigated.
Introduction: Quality care in breast cancer is higher if patients are treated in a Breast Center with a dedicated and specialized multidisciplinary team. Quality control is an essential activity to ensure quality care, which has to be based on the monitoring of specific quality indicators. Eusoma has proceeded with the up-dating of the 2017 Quality indicators for non-metastatic breast cancer based on the new diagnostic, locoregional and systemic treatment modalities.
View Article and Find Full Text PDFObjectives: To compare image quality of diffusion-weighted imaging (DWI) and contrast-enhanced breast MRI (DCE-T1) stratified by the amount of fibroglandular tissue (FGT) as a measure of breast density.
Methods: Retrospective, multi-reader, bicentric visual grading analysis study on breast density (A-D) and overall image and fat suppression quality of DWI and DCE-T1, scored on a standard 5-point Likert scale. Cross tabulations and visual grading characteristic (VGC) curves were calculated for fatty breasts (A/B) versus dense breasts (C/D).
Background: Comparing the impact of the COVID-19 pandemic on the incidence of newly diagnosed breast tumors and their tumor stage between the Netherlands and Norway will help us understand the effect of differences in governmental and social reactions towards the pandemic.
Methods: Women newly diagnosed with breast cancer in 2017-2021 were selected from the Netherlands Cancer Registry and the Cancer Registry of Norway. The crude breast cancer incidence rate (tumors per 100,000 women) during the first (March-September 2020), second (October 2020-April 2021), and Delta COVID-19 wave (May-December 2021) was compared with the incidence rate in the corresponding periods in 2017, 2018, and 2019.
Background Automated identification of quantitative breast parenchymal enhancement features on dynamic contrast-enhanced (DCE) MRI scans could provide added value in assessment of breast cancer risk in women with extremely dense breasts. Purpose To automatically identify quantitative properties of the breast parenchyma on baseline DCE MRI scans and assess their association with breast cancer occurrence in women with extremely dense breasts. Materials and Methods This study represents a secondary analysis of the Dense Tissue and Early Breast Neoplasm Screening trial.
View Article and Find Full Text PDFObjectives: Quality assurance (QA) of image interpretation plays a key role in screening and diagnostic mammography, maintaining minimum standards and supporting continuous improvement in interpreting images. However, the QA structure across Europe shows considerable variation. The European Society of Breast Imaging (EUSOBI) conducted a survey among the members to collect information on radiologists' preferences regarding QA measures in mammography.
View Article and Find Full Text PDFAxillary lymphadenopathy is a common side effect of COVID-19 vaccination, leading to increased imaging-detected asymptomatic and symptomatic unilateral axillary lymphadenopathy. This has threatened to negatively impact the workflow of breast imaging services, leading to the release of ten recommendations by the European Society of Breast Imaging (EUSOBI) in August 2021. Considering the rapidly changing scenario and data scarcity, these initial recommendations kept a highly conservative approach.
View Article and Find Full Text PDFPurpose: In breast conserving surgery, accurate lesion localization is essential for obtaining adequate surgical margins. Preoperative wire localization (WL) and radioactive seed localization (RSL) are widely accepted methods to guide surgical excision of nonpalpable breast lesions but are limited by logistical challenges, migration issues, and legislative complexities. Radiofrequency identification (RFID) technology may offer a viable alternative.
View Article and Find Full Text PDFBackground: In Dutch breast cancer screening, solitary, new or growing well-circumscribed masses should be recalled for further assessment. This results in cancers detected but also in false positive recalls, especially at initial screening. The aim of this study was to determine characteristics of well-circumscribed masses at mammography and identify potential methods to improve the recall strategy.
View Article and Find Full Text PDFPurpose: The aim of this study was to determine variability in visually assessed mammographic breast density categorization among radiologists practicing in Indonesia, the Netherlands, South Africa, and the United States.
Methods: Two hundred consecutive 2-D full-field digital screening mammograms obtained from September to December 2017 were selected and retrospectively reviewed from four global locations, for a total of 800 mammograms. Three breast radiologists in each location (team) provided consensus density assessments of all 800 mammograms using BI-RADS® density categorization.
Objectives: Computer-aided triaging (CAT) and computer-aided diagnosis (CAD) of screening breast magnetic resonance imaging have shown potential to reduce the workload of radiologists in the context of dismissing normal breast scans and dismissing benign disease in women with extremely dense breasts. The aim of this study was to validate the potential of integrating CAT and CAD to reduce workload and workup on benign lesions in the second screening round of the DENSE trial, without missing cancer.
Methods: We included 2901 breast magnetic resonance imaging scans, obtained from 8 hospitals in the Netherlands.
Background: Primary chemotherapy in breast cancer poses a dilemma with regard to adjuvant locoregional radiotherapy, as guidelines for locoregional radiotherapy were originally based on pathology results of primary surgery. We aimed to evaluate the oncological safety of de-escalated locoregional radiotherapy in patients with cT1-2N1 breast cancer treated with primary chemotherapy, according to a predefined, consensus-based study guideline.
Methods: In this prospective registry study (RAPCHEM, BOOG 2010-03), patients referred to one of 17 participating radiation oncology centres in the Netherlands between Jan 1, 2011, and Jan 1, 2015, with cT1-2N1 breast cancer (one to three suspicious nodes on imaging before primary chemotherapy, of which at least one had been pathologically confirmed), and who were treated with primary chemotherapy and surgery of the breast and axilla were included in the study.
The magnitude of the tradeoff between recall rate (RR) and cancer detection rate (CDR) in breast-cancer screening is not clear, and it is expected to depend on target population and screening program characteristics. Multi-reader multi-case research studies, which may be used to estimate this tradeoff, rely on enriched datasets with artificially high prevalence rates, which may bias the results. Furthermore, readers participating in research studies are subject to "laboratory" effects, which can alter their performance relative to actual practice.
View Article and Find Full Text PDFBMC Cancer
March 2022
Breast density is an independent risk factor for the development of breast cancer and also decreases the sensitivity of mammography for screening. Consequently, women with extremely dense breasts face an increased risk of late diagnosis of breast cancer. These women are, therefore, underserved with current mammographic screening programs.
View Article and Find Full Text PDFBackground In the Dutch breast cancer screening program, mammograms are preread by technologists to identify possible abnormalities, leading to "warning signals" (an audible and visual alert if the technologist observed an abnormality suspicious for cancer) for radiologists. The best moment to present these warning signals is unknown. Purpose To determine the effect that blinding of technologists' warning signals has on radiologists' early screening outcome measures during interpretation of mammograms.
View Article and Find Full Text PDFBackground Supplemental screening with MRI has proved beneficial in women with extremely dense breasts. Most MRI examinations show normal anatomic and physiologic variation that may not require radiologic review. Thus, ways to triage these normal MRI examinations to reduce radiologist workload are needed.
View Article and Find Full Text PDF