Rationale And Objectives: To compare performance of prospective interpretations of clinical tomosynthesis (digital breast tomosynthesis [DBT]) plus full-field digital mammography (FFDM) examinations with retrospective readings of the corresponding FFDM examinations alone.
Methods And Materials: Seven Mammography Quality Standard Act-qualified radiologists retrospectively interpreted 10,878 FFDM examinations that had been interpreted by other radiologists during prospective clinical interpretations of DBT plus FFDM. The radiologists were blinded to the Breast Imaging Reporting and Data System (BIRADS) category given during the clinical interpretations and the verified outcome by follow-up and/or any diagnostic workup that may have followed.
Objective: Digital mammography combined with tomosynthesis is gaining clinical acceptance, but data are limited that show its impact in the clinical environment. We assessed the changes in performance measures, if any, after the introduction of tomosynthesis systems into our clinical practice.
Materials And Methods: In this observational study, we used verified practice- and outcome-related databases to compute and compare recall rates, biopsy rates, cancer detection rates, and positive predictive values for six radiologists who interpreted screening mammography studies without (n = 13,856) and with (n = 9499) the use of tomosynthesis.