Publications by authors named "Rupak K Banerjee"

Ejection fraction is commonly used to assess Duchenne muscular dystrophy-associated cardiomyopathy (DMDAC), but it may remain normal (wrongly) despite significant myocardial dysfunction in patients. Therefore, better indicators of myocardial dysfunction are needed for longitudinal (with time) assessment and treatment of DMDAC patients. This study evaluates non-invasive LV PV loop-derived elastance, contractility and efficiency in relation to EF for patients developing DMDAC.

View Article and Find Full Text PDF

Background: Evaluating the severity of aortic stenosis (AS) can be challenging, particularly in patients with low-gradient (LG, Δp < 40 mmHg) AS.

Objective: This study aims to improve the accuracy of assessing severity of AS using a novel functional index- Aortic Valve Coefficient (AVC). The AVC is defined as ratio of mean transvalvular pressure-drop (Δp) to the proximal dynamic pressure (1/2 × blood density × V; V: left ventricular outflow tract peak velocity).

View Article and Find Full Text PDF

Investigating the influence of different cellular mechanical and physical properties on cells in vitro is important for assessing cellular activities like differentiation, proliferation, and migration. Evaluating the mechanical response of the cells lodged on a scaffold due to variations in substrate roughness, substrate elasticity, fluid flow, and the shapes of the cells is the main goal of the study. In this comprehensive analysis, a combination of the fluid structure interaction method and the submodeled finite element technique was employed to anticipate the mechanical responses across various cells at the interface between cells and the substrate.

View Article and Find Full Text PDF

Immunoassays based on reactions between target pathogen (antigen; Ag) and antibody (Ab) are frequently used for Ag detection. An external magnetic field was used to immobilize magnetic microbeads-tagged-antibodies (mMB-Ab) on the surface of a microchannel in the capture zone. The mMB-Ab was subsequently used for Ag detection.

View Article and Find Full Text PDF

Emergency medical service (EMS) providers have a higher potential exposure to infectious agents than the general public (Nguyen et al., 2020, "Risk of COVID-19 Among Frontline Healthcare Workers and the General Community: A Prospective Cohort Study," Lancet Pub. Health, (9), pp.

View Article and Find Full Text PDF

The present research investigates the pharmacokinetics and toxicity of a chitosan (CS) and poly(lactic-co-glycolic) acid (PLGA)-based methotrexate (MTX) intravitreal micro-implant in normal rabbit eyes. PLGA and CS-based micro-implants containing 400 µg of MTX were surgically inserted in the vitreous of twenty-four New Zealand rabbits using minimally invasive procedures. The PLGA-coated CS-MTX micro-implant and the placebo micro-implant were inserted in the right eye and in the left eye, respectively, of each rabbit.

View Article and Find Full Text PDF

Background: The current pressure-based coronary diagnostic index, fractional flow reserve (FFR), has a limited efficacy in the presence of microvascular disease (MVD). To overcome the limitations of FFR, the objective is to assess the recently introduced pressure drop coefficient (CDP), a fundamental fluid dynamics-based combined pressure-flow index.

Methods: We hypothesize that CDP will result in improved clinical outcomes in comparison to FFR.

View Article and Find Full Text PDF

In the absence of fit-testing, leakage of aerosolized pathogens through the gaps between the face and N95 respirators could compromise the effectiveness of the device and increase the risk of infection for the exposed population. To address this issue, we have developed a model to estimate the increase in risk of infection resulting from aerosols leaking through gaps between the face and N95 respirators. The gaps between anthropometric face-geometry and N95 respirators were scanned using computed tomography.

View Article and Find Full Text PDF

Purpose: To evaluate the safety and toxicity profile of a chitosan (CS) and poly(lactic-co-glycolic) acid (PLGA)-based sustained release methotrexate (MTX) intravitreal micro-implant in normal rabbit eyes using non-invasive testing that included electroretinography (ERG), ultrasound biomicroscopy (US), slit-lamp biomicroscopy (SLB), funduscopy, and intraocular pressure (IOP).

Methods: PLGA-coated CS-based micro-implants containing 400 μg of MTX and placebo (without drug) micro-implants were surgically-implanted in the vitreous of the right and the left eyes, respectively, in each of the thirty New Zealand rabbits. ERG, US, SLB, funduscopy, and IOP were assessed in both eyes at pre-determined time points (days: 1, 3, 7, 14, 28 and 56).

View Article and Find Full Text PDF

Background: Recirculation zones within the blood vessels are known to influence the initiation and progression of atherosclerotic lesions. Quantification of recirculation parameters with accuracy remains subjective due to uncertainties in measurement of velocity and derived wall shear stress (WSS).

Objective: The primary aim is to determine recirculation height and length from PIV experiments while validating with two different numerical methods: finite-element (FE) and -volume (FV).

View Article and Find Full Text PDF

The presence of bacterial pathogens in water can lead to severe complications such as infection and food poisoning. This research proposes a point-of-care electroosmotic flow driven microfluidic device for rapid isolation and detection of E. coli in buffered solution (phosphate buffered saline solution).

View Article and Find Full Text PDF

Pulmonary hypertension is characterized by elevation of pulmonary artery (PA) pressure (p) and structural remodeling of the PA wall, leading to reduction in arterial compliance (c). As a step towards improving diagnosis of pulmonary disease, we use the PA branch geometry (main pulmonary artery (MPA) branching into left (LPA) and right (RPA) pulmonary arteries) obtained from MRI in conjunction with an inverse algorithm to obtain the pre-stress level in the artery walls. Next, a coupled blood-wall interaction (BWI) calculation provides hemodynamic information as well as compliance of the PA walls.

View Article and Find Full Text PDF

Congenital pulmonary artery (PA) stenosis is often associated with abnormal PA hemodynamics including increased pressure drop (Δp) and reduced asymmetric flow (Q), which may result in right ventricular dysfunction. We propose functional diagnostic parameters, pressure drop coefficient (CDP), energy loss (E), and normalized energy loss (E¯) to characterize pulmonary hemodynamics, and evaluate their efficacy in delineating stenosis severity using in vitro experiments. Subject-specific test sections including the main PA (MPA) bifurcating into left and right PAs (LPA, RPA) with a discrete LPA stenosis were manufactured from cross-sectional imaging and 3D printing.

View Article and Find Full Text PDF

Purpose: The purpose of this study is to evaluate the impact of external head cooling on alleviating the heat stress in the human body by analyzing the temperatures of the core body (T), blood (T) and head (T) during exercise conditions using 3D whole body model.

Design/methodology/approach: Computational study is conducted to comprehend the influence of external head cooling on T, T and T. The Pennes bioheat and energy balance equations formulated for the whole-body model are solved concurrently to obtain T, T and T for external head cooling values from 33 to 233 W/m Increased external head cooling of 404 W/m is used to compare the numerical and experimental Th data.

View Article and Find Full Text PDF

Long procedure times and collateral damage remain challenges in high-intensity focused ultrasound (HIFU) medical procedures. Magnetic nanoparticles (mNPs) and gold nanoparticles (gNPs) have the potential to reduce the acoustic intensity and/or exposure time required in these procedures. In this research, we investigated relative advantages of using gNPs and mNPs during HIFU thermal-ablation procedures.

View Article and Find Full Text PDF

Repetitive intravitreal injections of Methotrexate (MTX), a hydrophilic chemotherapeutic drug, are currently used to treat selected vitreoretinal (VR) diseases, such as intraocular lymphoma. To avoid complications associated with the rapid release of MTX from the injections, a Polylactic acid (PLA) and Chitosan (CS)-based MTX micro-implant prototype was fabricated in an earlier study, which showed a sustained therapeutic release rate of 0.2-2.

View Article and Find Full Text PDF

Aim: To investigate the patient-outcomes of newly developed pressure drop coefficient (CDP) in diagnosing epicardial stenosis (ES) in the presence of concomitant microvascular disease (MVD).

Methods: Patients from our clinical trial were divided into two subgroups with: (1) cut-off of coronary flow reserve (CFR) < 2.0; and (2) diabetes.

View Article and Find Full Text PDF

Background: In this study, lesion flow coefficient (LFC: ratio of % area stenosis [%AS] to the square root of the ratio of the pressure drop across the stenosis to the dynamic pressure in the throat region), that combines both the anatomical (%AS) and functional measurements (pressure and flow), was assessed for application in a clinical setting.

Methods And Results: Pressure, flow, and anatomical values were obtained from patients in 251 vessels from two different centers. Fractional flow reserve (FFR), Coronary flow reserve (CFR), hyperemic stenosis resistance index (HSR) and hyperemic microvascular index (HMR) were calculated.

View Article and Find Full Text PDF

In this combined experimental and theoretical research, magnetic nano-particle (mNP) mediated energy transfer due to high intensity-focused ultrasound (HIFU) sonication has been evaluated. HIFU sonications have been performed on phantoms containing three different volume percentages (0%, 0.0047%, and 0.

View Article and Find Full Text PDF

Collateral damage and long sonication times occurring during high-intensity focused ultrasound (HIFU) ablation procedures limit clinical advancement. In this reserarch, we investigated whether the use of magnetic nano-particles (mNPs) can reduce the power required to ablate tissue or, for the same power, reduce the duration of the procedure. Tissue-mimicking phantoms containing embedded thermocouples and physiologically acceptable concentrations (0%, 0.

View Article and Find Full Text PDF

High-intensity focused ultrasound (HIFU) has gained increasing popularity as a noninvasive therapeutic procedure to treat solid tumors. However, collateral damage due to the use of high acoustic powers during HIFU procedures remains a challenge. The objective of this study is to assess the utility of using gold nanoparticles (gNPs) during HIFU procedures to locally enhance heating at low powers, thereby reducing the likelihood of collateral damage.

View Article and Find Full Text PDF

Heat stress experienced by firefighters is a common consequence of extreme firefighting activity. In order to avoid the adverse health conditions due to uncompensable heat stress, the prediction and monitoring of the thermal response of firefighters is critical. Tissue properties, among other parameters, are known to vary between individuals and influence the prediction of thermal response.

View Article and Find Full Text PDF

The important factors that affect the arterial wall compliance are the tissue properties of the arterial wall, the in vivo pulsatile pressure, and the prestressed condition of the artery. It is necessary to obtain the load-free geometry for determining the physiological level of prestress in the arterial wall. The previously developed optimization-based inverse algorithm was improved to obtain the load-free geometry and the wall prestress of an idealized tapered femoral artery of a dog under varying arterial wall properties.

View Article and Find Full Text PDF

Purpose: The purpose of this study is to noninvasively evaluate the safety and toxicity of a chitosan (CS) and polylactic acid (PLA)-based sustained-release methotrexate (MTX) intravitreal microimplant in normal rabbit eyes using electroretinography (ERG).

Methods: PLA-coated CS-based microimplants containing 400 μg of MTX and placebo microimplants (without drug) were surgically implanted in the vitreous of the right and the left eyes, respectively, in each of the 8 New Zealand rabbits using minimally invasive technique. At each predetermined time points (days 5, 12, 19, and 33), ERG was conducted on 2 rabbits to evaluate the safety of the microimplants administered in each eye.

View Article and Find Full Text PDF