Publications by authors named "Rump J"

Unlabelled: Better understanding of the lead curvature, movement and their spatial distribution may be beneficial in developing lead testing methods, guiding implantations and improving life expectancy of implanted leads.

Objective: The aim of this two-phase study was to develop and test a novel biplane cine-fluoroscopy-based method to evaluate input parameters for bending stress in leads based on their in vivo 3D motion using precisely determined spatial distributions of lead curvatures. Potential tensile, compressive or torque forces were not subjects of this study.

View Article and Find Full Text PDF

Breastfeeding (BF) in mothers living with HIV (MLWH) is still discussed controversially in resource-rich settings. In Germany, where formula feeding is recommended for MLWH single BF cases have been reported, but no systematic data collection and analysis are available so far. This study, titled HELENE, aims to fill this data gap.

View Article and Find Full Text PDF

While a variety of compounds containing planar tetracoordinated carbon (ptC), the so-called anti-van't Hoff/Le Bel carbon, are known experimentally, stable systems containing planar tetracoordinated silicon (ptSi) are barely known. As part of our studies on the application of stereoelectronically well-defined transition-metal fragments to stabilize silicon in unprecedented bonding modes, we report herein the synthesis and full characterization of a series of thermally stable complexes of the general formula [Tp'(CO)MSiC(R)C(R)M(CO)Tp'] (M = Mo, W; R = R = Me or R = H, R = SiMe, Ph; Tp' = κ-,',″-hydridotris(3,5-dimethylpyrazolyl)borate), which incorporate a ptSi atom in addition to two ptC atoms. The complexes were obtained by reacting the metallasilylidyne complexes [Tp'(CO)M≡Si-M(CO)(PMe)Tp'] with alkynes RC≡CR and were comprehensively analyzed by experimental studies and quantum chemical calculations.

View Article and Find Full Text PDF

Purpose: Evaluation of MR feasibility and real-time control of an innovative thermoablative applicator for intradiscal thermotherapy and histological analysis of laser annuloplasty in human ex vivo intervertebral discs.

Materials And Methods: We evaluated a new MR-compatible applicator system for MR-guided percutaneous intradiscal thermotherapy (MRgPIT) in an open 1.0-T MRI-system.

View Article and Find Full Text PDF

Neuralgic amyotrophy of the shoulder (Parsonage-Turner syndrome) is a rare condition of unknown aetiology which manifests as acute neuropathy of the brachial plexus. Diagnosis is based on typical symptoms and physical examination. In addition, magnetic resonance imaging of the affected shoulder and the cervical spine is advisable, in order to distinguish this syndrome from other conditions with similar symptoms.

View Article and Find Full Text PDF

Background And Study Aims: MRI-guided procedures combine high-quality imaging with lack of radiation. Percutaneous transhepatic cholangiodrainage under real-time MRI guidance (MRI-PTCD) seems promising, allowing targeted puncture and avoiding multiple blind passes and use of contrast, which are associated with standard PTCD's heaviest complications.

Patients And Methods: Aim of this study was to investigate the feasibility of MRI-PTCD in three outbred piglets.

View Article and Find Full Text PDF

Purpose: We aimed to validate actually achieved macroscopic ablation volumes in relation to calculated target volumes using four different radiofrequency ablation (RFA) systems operated with default settings and protocols for 3 cm and 5 cm target volumes in ex vivo bovine liver.

Materials And Methods: Sixty-four cuboid liver specimens were ablated with four commercially available RFA systems (Radionics Cool-tip, AngioDynamic 1500X, Boston Scientific RF 3000, Celon CelonPower LAB): 16 specimens for each system; eight for 3 cm, and eight for 5 cm. Ablation diameters were measured, volumes were calculated, and RFA times were recorded.

View Article and Find Full Text PDF

Objective: The purpose of this study was to examine the advantages of MRI-guided ankle stress examinations in the detection of chronic ankle instability.

Subjects And Methods: An MRI-compatible stress device was developed and tested for MRI safety. Bilateral MRI stress examinations were performed on 50 volunteers with and without clinically evident subjective instability of the ankle joints (72 subjective stable ankle joints in 37 subjects, 28 ankles in 15 subjects with chronic ankle instability).

View Article and Find Full Text PDF

Infections with HIV represent a great challenge for the development of strategies for an effective cure. The spectrum of diseases associated with HIV ranges from opportunistic infections and cancers to systemic physiological disorders like encephalopathy and neurocognitive impairment. A major progress in controlling HIV infection has been achieved by highly active antiretroviral therapy (HAART).

View Article and Find Full Text PDF

Objectives: The objective of this study was to evaluate the accuracy, safety, and efficacy of magnetic resonance (MR)-guided periradicular nerve root injection therapy using an open 1.0-T magnetic resonance imaging (MRI) system with fast dynamic imaging.

Materials And Methods: Between April 2008 and November 2011, a total of 249 MR-guided periradicular nerve root injections were performed in 141 patients experiencing lumbosacral radicular pain.

View Article and Find Full Text PDF

Objective: To prove that magnetic resonance imaging of foetal anatomy during the active second stage of vaginal delivery is feasible.

Materials And Methods: Initially, five pregnant volunteers around the 30th week of gestation were examined in an open MRI. Based on the findings, one vaginal delivery was acquired under real-time imaging.

View Article and Find Full Text PDF

The in vivo pain treatment was successfully performed with the patient in a prone position. The PD-weighted TSE with echo time = 10 ms rendered contrast-to-noise-ratio values of 27 ± 10 for needle/fat, 1.6 ± 5 for needle/muscle, and 4 ± 4.

View Article and Find Full Text PDF

Background: Complement receptor 2 (CR2/CD21) is part of the B-cell coreceptor and expressed by mature B cells and follicular dendritic cells. CD21 is a receptor for C3d-opsonized immune complexes and enhances antigen-specific B-cell responses.

Objective: Genetic inactivation of the murine CR2 locus results in impaired humoral immune responses.

View Article and Find Full Text PDF

The aim of this study was to develop a signal-inducing bone cement for magnetic resonance imaging (MRI)-guided cementoplasty of the spine. This MRI cement would allow precise and controlled injection of cement into pathologic lesions of the bone. We mixed conventional polymethylmethacrylate bone cement (PMMA; 5 ml methylmethacrylate and 12 g polymethylmethacrylate) with hydroxyapatite (HA) bone substitute (2-4 ml) and a gadolinium-based contrast agent (CA; 0-60 μl).

View Article and Find Full Text PDF

Aims: To assess percutaneous transhepatic cholangiodrainage (PTCD) under real-time MRI-guidance and compare it to procedures performed under fluoroscopy.

Methods: We developed an in vitro model for MRI-guided and conventional PTCD, using an animal organ set including liver and bile ducts placed in an MRI-compatible box and tested it in a 1.0-Tesla open MRI-scanner.

View Article and Find Full Text PDF

Purpose: The goal of this study was to investigate the impact of reduced k-space sampling rates on the visualization of a moving MR-compatible puncture needle and to demonstrate the feasibility of keyhole imaging in interventional magnetic resonance imaging (MRI).

Material And Methods: All experiments were performed in an open 1.0 Tesla MRI.

View Article and Find Full Text PDF

Purpose: To evaluate the feasibility of minimally invasive magnetic resonance imaging (MRI)-guided free-hand aspiration of symptomatic nerve route compressing lumbosacral cysts in a 1.0-Tesla (T) open MRI system using a tailored interactive sequence.

Materials And Methods: Eleven patients with MRI-evident symptomatic cysts in the lumbosacral region and possible nerve route compressing character were referred to a 1.

View Article and Find Full Text PDF

Purpose: Verification of MR-guidance with image acquisitions slower than 1 image per second as it is inevitable for some interventions. Therefore, we quantified solely the effect of acquisition-time on the efficiency of MR-guided interventions in a static phantom study.

Materials And Methods: We measured the duration, accuracy and error rate of simulated interventions for different acquisition-times using a simplified interventional setup.

View Article and Find Full Text PDF

Objective: To investigate the performance of an open MRI system at its conceptual limits by examining excessively obese patients who otherwise could not receive adequate imaging examinations.

Methods: Twenty-six excessively obese patients (BMI ≥ 35, average age 46) where CT, standard MR or ultrasound examinations were not possible or not conclusive were referred to an open MRI system at 1.0 Tesla.

View Article and Find Full Text PDF

The available MR-compatible communication systems, which are typically designed for diagnostic exams, are mostly based on tubular sound transmission. In other settings, modern commercially available communication systems with ear protection allow wireless communication in noisy environments. The application of MR-compatible wireless headsets in interventional radiology precludes tube contact with sterile surfaces and hindrance of the interventionalist's range of motion.

View Article and Find Full Text PDF

The introduction of tumor necrosis factor (TNF)-α inhibitors s in the late 1990s considerably broadened the treatment options for, and essentially contributed to the successful management of, rheumatoid arthritis (RA) and other immune-mediated inflammatory diseases. Nevertheless, their use during pregnancy is still controversially discussed since it remains unclear whether the benefits of treatment might be outweighed by potential teratogenicity or adverse effects on the course of pregnancy. In this case series report we describe the course and outcome of eight pregnancies in five women (four with RA and one with ankylosing spondylitis) at our private clinical practice treated with the TNF-α inhibitor etanercept at the time of conception and during pregnancy.

View Article and Find Full Text PDF

Objective: To evaluate the feasibility and safety of a novel LITT applicator for thermal ablation of liver malignancies in 1.0-T high-field open MRI.

Methods: A miniaturised 6-F double-tubed protective catheter with a closed cooling circuit was used with a flexible laser fibre, connected to a 1,064-nm Nd:YAG laser and evaluated in non-perfused porcine livers (18-30 W for 10-20 min, 2-W and 2-min increments; n = 210/applicator) in reference to an established 9-F system.

View Article and Find Full Text PDF

Purpose: To validate an unspoiled gradient-recalled echo pulse sequence with dual echo acquisition as a means to increase temperature sensitivity while monitoring intradiscal laser ablation therapy.

Materials And Methods: Phantom experiments as well as in vitro thermal ablation simulations were performed in an open 1.0T magnetic resonance (MR) scanner.

View Article and Find Full Text PDF

Computer-assisted surgery is currently a novel challenge for surgeons and interventional radiologists. Magnetic resonance imaging (MRI)-guided procedures are still evolving. In this experimental study, we describe and assess an innovative passive-navigation method for MRI-guided treatment of osteochondritis dissecans of the knee.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to evaluate different methods of magnetic resonance thermometry (MRTh) for the monitoring of intradiscal laser ablation therapy in an open 1.0 Tesla magnetic resonance (MR) scanner.

Material And Methods: MRTh methods based on the two endogenous MR temperature indicators of spin-lattice relaxation time T1 and water proton resonance frequency (PRF) shift were optimised and compared in vitro.

View Article and Find Full Text PDF