Objective: The primary goal of this investigation was to ascertain the efficacy of the CALM motion artifact reduction algorithm in diminishing motion-induced blurriness in Cone Beam Computed Tomography [CBCT] images. The assessment was conducted through Fractal Dimension [FD] analysis of the trabecular bone.
Methods And Materials: A desiccated human mandible was subjected to Planmeca ProMax 3D scanning under eight distinct protocols, marked by variations in motion presence [at 5, 10, and 15 degrees] and the deployment of CALM.
Purpose: The aim of this study was to evaluate 3-dimensional cone-beam computed tomography (CBCT) images of alveolar bone changes in patients who underwent minimally invasive periodontal surgery-namely, the pinhole surgical technique (PST).
Materials And Methods: Alveolar bone height was measured and compared on CBCT images of 254 teeth from 23 consecutive patients with Miller class I, II, or III recession who had undergone PST. No patient with active periodontal disease was selected for surgery.
Objectives: Determine the effect of the motion correction system on cone-beam computed tomography (CBCT) image quality parameters, artifacts, and contrast-to-noise ratio (CNR) using different motion settings.
Materials And Methods: A customized phantom insert array was prepared using SEDENTEX CT IQ Phantom (Leeds Test Objects, Yorkshire, England) stabilized over a rotating electric turntable. Thirty baseline CBCT scans were acquired with standardized technique factors on the ProMax 3D (Planmeca, Helsinki, Finland) machine using combinations of different motion settings, including no motion, three- and six-degree motion, and with and without the use of a motion correction system.
Immune checkpoint inhibitors (ICIs) have revolutionized the treatment of advanced malignancies, including non-small cell lung cancer (NSCLC). These agents have improved clinical outcomes and have become quite an attractive alternative alone or combined with other treatments. Although ICIs are tolerated better, they also lead to unique toxicities, termed immune-related adverse events (irAEs).
View Article and Find Full Text PDFPurpose/objectives: To understand the professional aspirations of oral and maxillofacial radiologists (OMRs) by exploring their career choices and their association with educational background, engagement in professional activities, professional values, and overall level of career satisfaction.
Methods: This prospective cross-sectional study surveyed board-certified OMRs in the United States and Canada from September to December 2019. A web-based questionnaire was created comprising 37 multiple-choice questions and an open-ended question focusing on their opinions regarding the profession's future.
Oral Surg Oral Med Oral Pathol Oral Radiol
May 2020
Objectives: The aim of this ex vivo study was to measure the sensitivity, specificity, and receiver operating characteristic (ROC) area under the curve (AUC) of a caries diagnostic system based on photothermal radiometry and modulated luminescence (PTR/LUM) and compare them with the values for digital intraoral radiography (IR) and cone beam computed tomography (CBCT) in detecting recurrent decay.
Study Design: Class 2 composite restorations were prepared on 70 proximal surfaces: 35 with caries and 35 without caries. The gingival floor of the restored surfaces was assessed for caries under the restorations using each of the 3 modalities.
Objectives: To implement the quality control assurance protocol (including the re-establishment of baseline data from 2016) to monitor the stability of image quality of CBCT machines located within the UT Health San Antonio School of Dentistry.
Methods And Materials: Five CBCT machines ProMax 3D Mid® (Planmeca Oy, Helsinki, Finland), 3D Accuitomo XYZ Slice View Tomograph® (Model MCT-1, Type EX-1F8; Fushimi-ku, Kyoto: J. Morita Mfg.
Oral Surg Oral Med Oral Pathol Oral Radiol
June 2019
Objective: The aim of this study was to assess artifacts generated by zirconium, titanium, and titanium-zirconium alloy implants on magnetic resonance imaging(MRI), computed tomography(CT), and cone beam computed tomography(CBCT) and to correlate the findings to the dose-area product and exposure factors on CT and CBCT.
Study Design: Three phantoms were built by embedding zirconium, titanium, and titanium-zirconium implants in ultrasound gel. MRI, CT, and CBCT images were acquired by using multiple sequences and settings.
Optical coherence tomography (OCT) is a noninvasive diagnostic technique providing cross-sectional images of biologic structures based on the differences in tissue optical properties. OCT has been widely used in numerous clinical applications and is becoming popular as a promising technology in dentistry. Today, dental hard (tooth) and soft (hard palate mucosa and gingiva mucosa) tissues are visualized with OCT.
View Article and Find Full Text PDFThree-dimensional (3D) volume-rendered images allow 3D insight into the anatomy, facilitating surgical treatment planning and teaching. 3D printing, additive manufacturing, and rapid prototyping techniques are being used with satisfactory accuracy, mostly for diagnosis and surgical planning, followed by direct manufacture of implantable devices. The major limitation is the time and money spent generating 3D objects.
View Article and Find Full Text PDFIntroduction: Increased galectin-3 is associated with ischemic cardiomyopathy, although its role in early remodeling post-myocardial infarction (MI) has not been fully elucidated. There are no data demonstrating that blocking galectin-3 expression would have an impact on the heart and that its relationship to remodeling is not simply an epiphenomenon. The direct association between galectin-3 and myocardial inflammation, dysfunction, and adverse cardiovascular outcomes post-MI was examined using clinical and translational studies.
View Article and Find Full Text PDFOral Surg Oral Med Oral Pathol Oral Radiol
May 2017
Objectives: The aim of this study was to evaluate the effect of an optimization filter (OF) and voxel size on the accuracy of root fracture detection.
Study Design: Half of 40 endodontically treated roots were fractured, and the other half were left intact. All teeth were randomly placed into 5 bovine ribs.
Background: Acute myocardial infarction (MI) causes significant changes in cardiac morphology and function. Galectin-3 is a novel and potentially therapeutically important mediator of cardiac remodelling. Myocardial and serum galectin-3 expression dynamics in response to the early cardiovascular outcomes after acute MI are not fully elucidated.
View Article and Find Full Text PDFOral Surg Oral Med Oral Pathol Oral Radiol
November 2016
Objectives: The aim of this study was to evaluate the effect of milliamperage, number of basis images, and export slice thickness on contrast-to-noise ratio (CNR) and confidence in detecting mandibular canal.
Study Design: Two phantoms were used. Each phantom consisted of a dry mandible with an epoxy resin bone tissue substitute block and a water-equivalent block, submerged in water.
Arrested pneumatization of the sphenoid sinus is a normal anatomical variant. The aim of this report is to define cone beam computed tomography (CBCT) characteristics of arrested pneumatization of sphenoid sinus in an effort to help differentiate it from invasive or lytic skull base lesions. Two cases are presented with incidental findings.
View Article and Find Full Text PDFIntroduction: Cone-beam computed tomography (CBCT) gives orthodontists and other dental clinicians 3-dimensional information for planning treatment in the craniofacial region. Often overlooked are incidental findings outside the treatment region of interest.
Methods: Two patients with incidental findings of skull-base abnormalities are presented.
Objective: To discuss the challenges in diagnosis and appropriate management of critical underlying pathoses if a patient presents with signs and symptoms indicative of different conditions that may coexist.
Summary: This case features clinical and radiographic challenges in reaching a diagnosis in a middle- aged man undergoing bisphosphonate therapy for multiple myeloma. The patient had history of bisphosphonaterelated osteonecrosis of the jaw (BRONJ) in the mandible.
Aims: The aim of this study is to evaluate the course of the inferior alveolar canal (IAC) including its frequently seen variations in relation to root apices and the cortices of the mandible at fixed pre-determined anatomic reference points using cone beam volumetric computed tomography (CBVCT).
Material And Methods: This retrospective study utilized CBVCT images from 44 patients to obtain quantifiable data to localize the IAC. Measurements to the IAC were made from the buccal and lingual cortical plates (BCP/LCP), inferior border of the mandible and the root apices of the mandibular posterior teeth and canine.