Publications by authors named "Ruffin Graham"

The typical findings of COVID-19 on chest radiography and computed tomography (CT) include bilateral, multifocal parenchymal opacities (ground-glass opacities with or without consolidation, and "crazy paving"). In most cases, the opacities are predominantly in the peripheral and lower lung zones, and several have rounded morphology. However, these imaging findings are not pathognomonic for COVID-19 pneumonia and can be seen in other viral and bacterial infections, as well as with noninfectious causes such as drug toxicity and connective tissue disease.

View Article and Find Full Text PDF

The aim of this brief report is to determine the safety and reliability of minimally invasive video-assisted thoracic surgery (VATS) resection without the aid of intraoperative fluoroscopy after computed tomography (CT)-guided microcoil localization of small peripheral pulmonary nodules. Twenty patients with peripheral lung nodules underwent percutaneous needle localization with a microcoil that was tagged back to the visceral pleural surface. Same-day VATS resection was performed without the use of intraoperative fluoroscopy.

View Article and Find Full Text PDF

Purpose To compare the diagnostic yield and complication rates of electromagnetic navigational bronchoscopic (ENB)-guided and computed tomography (CT)-guided percutaneous tissue sampling of lung nodules. Materials and Methods Retrospectively identified were 149 patients sampled percutaneously with CT guidance and 146 patients who underwent ENB with transbronchial biopsy of a lung lesion between 2013 and 2015. Clinical data, incidence of complications, and nodule pathologic analyses were assessed through electronic medical record review.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to evaluate the impact of attenuation-based kilovoltage (kV) pair selection in dual source dual energy (DSDE)-pulmonary embolism (PE) protocol examinations on radiation dose savings and image quality.

Methods: A prospective study was carried out on 118 patients with suspected PE. In patients in whom attenuation-based kV pair selection selected the 80/140Sn kV pair, the pre-scan 100/140Sn CTDIvol (computed tomography dose index volume) values were compared with the pre-scan 80/140Sn CTDIvol values.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to evaluate blindly breast ultrasound images corrected for the speed of sound in breast tissue compared with conventional images.

Materials And Methods: In this study, 409 images from 153 patients were obtained on an Antares Ultrasound system. The system was modified to process the radiofrequency data with the standard 1540 m/s as the speed of sound and at a corrected speed of sound for breast tissue.

View Article and Find Full Text PDF