Purpose: The aim of this study was to assess the microbiological and clinical outcomes of implant-supported restorations on zirconia or titanium abutments after 3 years in function.

Materials And Methods: Twenty two-part dental implants were placed in 20 healthy individuals in need of single-tooth replacement. Ceramic-based reconstructions were cemented in either zirconia or titanium abutments.

View Article and Find Full Text PDF

Background: Clinical success with mandibular implant overdentures is highly dependent on a reliable attachment system connecting prosthesis and implants.

Purpose: To compare the levels of retention and patient-based outcomes on implant overdentures retained/supported by cylindrical (LA) and ball (RA) attachment systems overtime and investigate their relationship.

Materials And Methods: Attachment retention (Newtons), and patient satisfaction with the treatment, prosthesis stability, and ability to chew (VAS, 100 mm) were assessed in a crossover trial for both attachment systems at baseline, 1 week, 3, 6, and 12 months and compared to preintervention values.

View Article and Find Full Text PDF

Dental implants and their prosthetic components are prone to bacterial colonization and biofilm formation. The use of materials that provides low microbial adhesion may reduce the prevalence and progression of peri-implant diseases. In view of the oral environment complexity and oral biofilm heterogeneity, microscopy techniques are needed that can enable a biofilm analysis of the surfaces of teeth and dental materials.

View Article and Find Full Text PDF

The aim of this qualitative study was to gain a deeper understanding of patient perceptions of wearing implant-retained overdentures with ball-shaped or cylindrical attachment systems. Twenty-two wearers of implant-supported overdentures participated in this qualitative study based on a randomized crossover clinical trial that aimed to compare a cylindrical attachment and a ball attachment. In phase I of the study, group A experienced ball attachments (n = 11) and group B Locator attachments (n = 11) for 1 year.

View Article and Find Full Text PDF

Background: Mini dental implants (MDIs) are becoming increasingly popular for rehabilitation of edentulous patients because of their several advantages. However, there is a lack of evidence on the osseointegration potential of the MDIs. The objective of the study was to histomorphometrically evaluate and compare bone apposition on the surface of MDIs and standard implants in a rabbit model.

View Article and Find Full Text PDF

Background: One-piece narrow diameter implants (NDIs) have been recommended as "Single-tooth replacements in the anterior zones, single posterior, multiple-unit fixed dental prosthesis (FDP), edentulous jaws to be rehabilitated with FDP, and edentulous jaws rehabilitation with overdentures in situations with reduced mesiodistal space or reduced ridge width." (ITI consensus 2013). Since NDIs can be immediately loaded, it is important to be able to carry out stability testing.

View Article and Find Full Text PDF

Bacterial contamination on titanium implants can cause inflammation and eventually implant failure. Currently used methods for decontamination of implants have demonstrated limited success. Metal surfaces can be disinfected electrochemically.

View Article and Find Full Text PDF

Microbial etiology for anti-osteoclastic drug-related osteonecrosis of the jaw (ARONJ) was suggested. This study investigates any link between bacteria colonizing ARONJ sites and other oral cavity sites. Microbiota samples of 10 ARONJ patients were collected from the exposed bone, adjacent teeth, contralateral teeth, and tongue.

View Article and Find Full Text PDF

Objective: To characterize the profile of microbial communities colonizing titanium implants with different surface treatments after exposure to the oral environment at the genus or higher taxonomic level.

Material And Methods: Sixteen titanium disks, machined or sandblasted large-grit and acid-etched (SLA), were mounted on removable intraoral splints worn by four patients. After 24 h of intraoral exposure, biofilm samples were collected from disks and supra/subgingival teeth areas.

View Article and Find Full Text PDF

Statement Of Problem: Bidirectional leakage through the implant-abutment interface still constitutes a major concern in implant-supported restorations.

Purpose: The purpose of this in vitro study was to evaluate the marginal fit, before and after loading simulation, of 3-unit fixed partial prostheses supported by external hexagon or Morse cone implants and to identify and quantify up to 43 microbial species penetrating through the implant-abutment interface after loading.

Material And Methods: Forty-eight dental implants with external hexagon (EH; n=24) or Morse cone (MC; n=24) connections were investigated.

View Article and Find Full Text PDF

Objective: This study aimed to evaluate the impact of concurrent administration of clinically relevant doses of zoledronic acid (ZA) and dexamethasone (DX) on bone healing after tooth extraction (EXO).

Materials And Methods: Forty-four Sprague-Dawley rats (6-8 month old) were randomized into five groups: ZA + DX = weekly injection of ZA with DX for 7 weeks; WD = ZA with DX for 3 weeks then DX alone for 4 weeks; C = control saline for 7 weeks; ZA = ZA alone for 7 weeks and DX = DX alone for 7 weeks. ZA was administered at 0.

View Article and Find Full Text PDF

Purpose: Molecular diagnosis methods have been largely used in epidemiological or clinical studies to detect and quantify microbial species that may colonize the oral cavity in healthy or disease. The preservation of genetic material from samples remains the major challenge to ensure the feasibility of these methodologies. Long-term storage may compromise the final result.

View Article and Find Full Text PDF

Objective: The aim of this randomized crossover investigation was to assess the biofilm formation on two titanium and one zirconia substrates in relation to the topography and surface roughness of the materials.

Methods: Twenty-four discs specimens for each evaluated material (Machined pure titanium, Cast pure titanium, or Zirconia) were evaluated after oral cavity exposure in six healthy subjects. The study was conducted in 3 phases according to the material evaluated.

View Article and Find Full Text PDF

Purpose: Bacterial leakage along the implant-abutment interface, with consequent species harboring the inner parts of two-part dental implant systems, has been reported in the literature. The aim of this in vitro study was to evaluate bacterial leakage from human saliva to the internal part of the implants along the implant-abutment interface under loaded and unloaded conditions using DNA Checkerboard.

Materials And Methods: Sixty dental implants--20 each of external-hexagon, internal-hexagon, and Morse cone-connection designs--and their conical abutments were used in this study.

View Article and Find Full Text PDF

Statement Of Problem: Matrices of unsplinted attachment systems are generally reported to be the weak component of implant overdentures, often requiring frequent maintenance. Clinical wear results in reduced retention of the prosthesis, requiring activation or renewal of the matrix to restore the initial level of retention.

Purpose: The purpose of this retrospective study was to measure the wear of the matrix of a ball attachment after various periods of clinical wear.

View Article and Find Full Text PDF

Objectives: Tooth shade is influenced by a combination of extrinsic-stains that are adsorbed to the enamel surface and by its intrinsic-shade resulting from the interaction of light with tooth structures. This study was designed to investigate how the variations in enamel ultrastructure may affect tooth optical properties.

Methods: One-hundred extracted teeth were collected from adult patients attending McGill-Undergraduate Dental Clinics.

View Article and Find Full Text PDF

Objective: Bacterial species have been found harboring the internal surface of dental implants as consequence of their failed connections. The aim of the present study was to compare the detection frequency of bacterial leakage from human saliva through the implant-abutment interface, under non-loading conditions, using either DNA Checkerboard or culture method.

Materials And Methods: Thirty dental implants with hexagonal platforms were connected to pre-machined abutments according to the manufacturers' specifications.

View Article and Find Full Text PDF

Background: The aim of this study was to compare the shear bond strength between Ni-Cr alloy specimens bonded to air-abraded Ni-Cr, bur-abraded Ni-Cr, etched ceramic and etched enamel substrates using the resin cements RelyX ARC or Enforce.

Materials And Methods: Ni-Cr specimens were made and sandblasted with Al(2)O(3) airborne-particles. Disc-shaped patterns were made for each of the four experimental substrates: Ni-Cr treated with Al(2)O(3) airborne-particles, Ni-Cr treated with diamond bur abrasion, etched enamel and etched ceramic.

View Article and Find Full Text PDF

Objectives: Implant-supported overdentures have become the treatment of choice in restoring complete edentulism, but the types of attachment to assure durable retention are a subject of debate. Ball attachments were reported as a simple treatment, but wear of components was responsible for a decrease in retention. The aim of this retrospective study was to measure the wear of the ball abutment or patrix after three different periods of clinical wear.

View Article and Find Full Text PDF

The purpose of this study was to analyze and compare scanning electron microscopy (SEM) observations of ball attachments that had been worn by patients during three periods of clinical use. One hundred forty-four specimens of ball anchor attachments (gold alloy matrix and titanium patrix) were studied by SEM after periods of approximately 1, 3.5, and 8 years of clinical use.

View Article and Find Full Text PDF

Background: Distraction osteogenesis (DO) is a method of producing new bone directly from the osteotomy site by gradual traction of the divided bone fragments.

Aim: The purpose of the present study was to evaluate histomorphometrically whether acute DO would constitute a viable alternative to the conventional continuous distraction treatment and also to verify the capacity of a recombinant human BMP (rhBMP-2) associated with monoolein gel to stimulate bone formation in the acute distraction process.

Materials And Methods: Forty-eight Wistar rats were assigned to three groups: Group 1, treated at a conventional continuous distraction rate (0.

View Article and Find Full Text PDF

Objectives: Bacterial penetration along the implant-abutment interface as a consequence of abutment screw loosening has been reported in a number of recent studies. The aim of this in vitro study was to investigate the influence of repeated tightening of the abutment screw on leakage of Streptococcus mutans along the interface between implants and pre-machined abutments.

Materials And Methods: Twenty pre-machined abutments with a plastic sleeve were used.

View Article and Find Full Text PDF

Purpose: The aim of this in vitro study was to evaluate the bacterial leakage along the implant-abutment interface by the conventional bacterial culture and DNA Checkerboard hybridization method.

Materials And Methods: Twenty Branemark-compatible implants with a 3.75-mm diameter and external hexagonal platform were randomly placed in two groups of ten implant-abutment assemblies each.