Publications by authors named "Ru Yu Tan"

Background: A multidisciplinary care model involving the interventional radiologist, vascular surgeon, interventional nephrologist, renal advanced nurse practitioner, and renal coordinators was implemented to improve the care for the patient admitted with dysfunctional hemodialysis access. This study aims to evaluate the effectiveness and sustainability of this multidisciplinary care model.

Method: A dedicated interventional nephrology suite was established to perform endovascular procedures for patients admitted with hemodialysis access dysfunction via the emergency department of the hospital.

View Article and Find Full Text PDF

Background: This study aims to evaluate the safety and efficacy of a short-term, low dose, weight-based subcutaneous enoxaparin protocol (SEP) in maintaining the patency of arteriovenous (AV) access with recurrent thrombosis.

Methods: Prospective follow-up of 25 patients who presented to a tertiary institution with recurrent AV access thrombosis and treated with anticoagulation according to SEP following successful thrombectomy. Patency and safety outcomes of SEP were studied.

View Article and Find Full Text PDF

Background: Treatment of cephalic arch stenosis (CAS) is associated with high risk of failure and complications. Although stent-graft (SG) placement has improved patency rates, stent edge restenosis has been raised as a potential limiting factor for SG usage in CAS. This study aims to evaluate the safety and efficacy of combining stent graft placement with paclitaxel-coated balloon (PCB) angioplasty versus PCB alone in the treatment of CAS.

View Article and Find Full Text PDF

Fibroblast growth factor 21 (FGF-21) is an evolutionarily conserved protein that plays multiple roles in metabolic regulation. Over the past two decades, numerous studies have deepened our understanding of its various functions and its pharmacological value. Nevertheless, most clinical trials have not achieved the desired results, which raises issues regarding its clinical value.

View Article and Find Full Text PDF

Introduction: Double-filtration plasmapheresis (DFPP) has been utilized for immunomodulation in kidney transplantation. Anticoagulation is important to maintain circuit patency during DFPP. We aimed to compare the efficacy and safety of regional citrate anticoagulation (RCA) with systemic heparin anticoagulation during DFPP in kidney transplant recipients.

View Article and Find Full Text PDF

Background: A prospective, pilot study was designed to test the feasibility of using sirolimus-coated balloon (SCB) to treat graft vein junction of thrombosed arteriovenous graft (AVG) following successful pharmacomechanical thrombectomy. The present report provides the 1-year results of this study.

Methods: This is a 1-year follow-up of a single, prospective, single-arm study that was conducted from 2018 to 2019 in 20 patients who presented to a tertiary institution with thrombosed AVG.

View Article and Find Full Text PDF

Background: Aim was to compare the safety and patency efficacy outcomes between Ranger™ paclitaxel-coated balloon (PCB)- versus conventional balloon angioplasty (POBA) in the treatment of haemodialysis access-related conduit stenosis.

Methods: Retrospective single-centre, multi-investigator, consecutive, double-arm comparative cohort study. About 130 end-stage renal failure Asian patients with dysfunctional arteriovenous fistula (AVF) or arteriovenous graft underwent PCB or POBA fistuloplasty between November 2018 and June 2020.

View Article and Find Full Text PDF

Background: Aim of this pilot clinical study was to evaluate the safety and efficacy of the ™ sirolimus-eluting balloon (SEB) for improving failing arterio-venous fistulas (AVF) patency in Asian haemodialysis patients.

Methods: Prospective single-centre, multi-investigator, non-consecutive, non-blinded single arm trial. Forty end-stage renal failure Asian patients with a dysfunctional AVF underwent SEB angioplasty between May and November 2020.

View Article and Find Full Text PDF

Background: Percutaneous transluminal angioplasty is the current standard treatment for arteriovenous fistula (AVF) stenosis. The mid- and long-term patency with plain balloon angioplasty (PBA) is however far from satisfactory. While paclitaxel-coated balloon angioplasty has been shown to be superior to PBA, concern over its safety profile has recently arisen after a reported possible increased mortality risk with a meta-analysis of large lower limb studies.

View Article and Find Full Text PDF

Background: Treatment of cephalic arch stenosis (CAS) with standard plain old balloon angioplasty (POBA) in dysfunctional arteriovenous fistulas (AVF), is associated with early re-stenosis and higher failure rates compared to other lesions. Paclitaxel-coated balloons (PCB) may improve patency rates. This is a retrospective cohort study.

View Article and Find Full Text PDF

Background: Aim of Arch V SUPERA-LUX was to evaluate the safety and efficacy of the combination therapy of SUPERA™ (, Santa Clara, CA, USA) helical stent implantation and Passeo-18 Lux™ ( Asia Pacific Pte Ltd, Singapore) drug coated balloon (DCB) elution to treat recurrent cephalic arch stenosis (CAS) in the setting of AV access dysfunction.

Methods: Investigator-initiated, single-center, single-arm prospective pilot study of 20 end-stage renal failure Asian patients with a dysfunctional brachiocephalic fistula. All had symptomatic recurrent CAS within 6 months of prior intervention.

View Article and Find Full Text PDF

Background: The aim of this pilot clinical study is to evaluate the safety and efficacy of the ™ sirolimus-coated balloon (M.A. MedAlliance SA, Nyon, Switzerland) for improving the patency of failing arterio-venous fistulas (AVF) in hemodialysis patients.

View Article and Find Full Text PDF

Background And Aims: Individuals undergoing kidney biopsy are increasingly older and may have concurrent illnesses that cause deranged hematological and renal parameters that are associated with post-biopsy bleeding. We aimed to develop a clinical risk model to quantify bleeding risks in high-risk individuals with multiple risk factors.

Methods: Single-center retrospective cohort study of consecutive adults with serum creatinine ≥ 2 mg/dL (176 µmol/L) and had ultrasound-guided percutaneous native kidney biopsies between June 2011 and July 2015 in our tertiary referral center.

View Article and Find Full Text PDF

Background: The optimal vascular access strategy in elderly patients receiving haemodialysis (HD) remains controversial. We aim to report the outcomes of arteriovenous fistula (AVF) in elderly patients initiated on maintenance HD in our centre.

Methods: Medical records of 688 incident patients initiated on HD from 2010 to 2012 in a tertiary centre were retrospectively reviewed.

View Article and Find Full Text PDF

This paper documents our experience using the Cleaner XT™ device (Argon Medical Devices, Plano, TX, USA) for pharmacomechanical thrombolysis (PMT) of thrombosed haemodialysis arteriovenous grafts (AVG) and fistulas (AVF). This was a retrospective case series (n=17) over six months at Singapore General Hospital. We evaluated demographics, procedural data, technical and procedural success, patency rates and complications.

View Article and Find Full Text PDF

Background: The aim of this study was to review the efficacy of the Flixene™ (Atrium™, Hudson, NH, USA) hemodialysis arterio-venous graft (AVG) in a multiethnic Asian cohort of patients with end-stage renal failure (ESRF). Primary outcome was graft primary patency rate and secondary end points included graft usability, time to cannulation, reinterventions required for access salvage, complications, and patient mortality.

Methods: Single-center, single-arm, multi-investigator nonrandomized retrospective study.

View Article and Find Full Text PDF

Purpose: To investigate the use of a sirolimus drug-coated balloon (DCB) in the management of a thrombosed arteriovenous graft (AVG).

Materials And Methods: A single-center prospective pilot study was conducted between October 2018 and October 2019. Twenty patients (age = 67.

View Article and Find Full Text PDF

Aim: This study aims to investigate the effect of low molecular weight heparin (LMWH) in maintaining the patency of arteriovenous (AV) access with recurrent thrombosis.

Methods: Following successful thrombectomy, 66 patients with recurrent thrombosis were included in the study. The primary, assisted primary and secondary patency rates of patients who received LMWH (n = 24) were compared with those who did not receive anticoagulant (n = 42) using Kaplan-Meier analysis.

View Article and Find Full Text PDF

Background: The aim of this pilot study was to evaluate the safety and efficacy of the MagicTouch™ sirolimus-coated balloon (SCB) catheter (Concept Medical Inc., Tampa, FL, US) on improving the patency of failing arterio-venous fistulas (AVF) with de novo and recurrent stenoses. MATILDA reports early outcomes at 3- and 6 months post intervention.

View Article and Find Full Text PDF

Background: In arteriovenous graft (AVG) for haemodialysis, the primary cause of failure is venous stenosis of the graft-vein junction from neointimal hyperplasia (NIH), resulting in thrombosis. While interventions to salvage clotted AVG are known to have high clinical success rates, long-term patency rates have been suboptimal. Drug-coated balloon (DCB) has been used to treat stenosed arteriovenous access in recent years with encouraging results but data on its effect in clotted AVG is unavailable.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessiont6hm9n0dq8h8g5b27dplua6tqe0tm24h): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once