Publications by authors named "Roze S"

Clinical trials and real-world data for Type II diabetes both show that glycated hemoglobin (HbA1c) levels and hypoglycemia occurrence can be reduced by real-time continuous glucose monitoring (rt-CGM) versus self-monitoring of blood glucose (SMBG). The present cost-utility study investigated the long-term health economic outcomes associated with using rt-CGM versus SMBG in people with insulin-treated Type II diabetes in France. Effectiveness data were obtained from a real-world study, which showed rt-CGM reduced HbA1c by 0.

View Article and Find Full Text PDF

Aims/hypothesis: The aim of this study was to assess the long-term cost-effectiveness of Dexcom G6 real-time continuous glucose monitoring (rtCGM) with alert functionality compared with FreeStyle Libre 1 intermittently scanned continuous glucose monitoring (isCGM) without alerts in adults with type 1 diabetes in Belgium.

Methods: The IQVIA CORE Diabetes Model was used to estimate cost-effectiveness. Input data for the simulated baseline cohort were sourced from the randomised ALERTT1 trial (ClinicalTrials.

View Article and Find Full Text PDF

Background: To estimate the economic impact of preventing urinary tract infections (UTI) by increasing water intake among women with recurrent UTI and low fluid intake across seven countries: France, United Kingdom, Spain, United States of America, Mexico, China and Australia.

Methods: A Markov model was developed to compare costs and outcomes of UTIs associated with low fluid intake in women versus a strategy of primary prevention by increasing water intake. Model inputs were based on randomized controlled trial data which found that increasing water intake by 1.

View Article and Find Full Text PDF
Article Synopsis
  • Real-time continuous glucose monitoring (rt-CGM) leads to lower glycated hemoglobin (A1c) levels and reduced hypoglycemia compared to self-monitoring of blood glucose (SMBG) for insulin-treated Type 2 diabetes patients.
  • An analysis of health and economic outcomes in Canada found that using rt-CGM resulted in higher lifetime costs (CAD 207,466) but also better quality-adjusted life expectancy (9.97 QALYs) compared to SMBG (CAD 189,863 and 9.02 QALYs, respectively).
  • The incremental cost-utility ratio (ICUR) for rt-CGM was CAD 18,523 per QALY gained, suggesting that rt-CGM is likely a
View Article and Find Full Text PDF

Aims: To determine the cost-effectiveness of the Dexcom G6 real-time continuous glucose monitoring (rt-CGM) system compared with both the self-monitoring of blood glucose (SMBG) and the Abbott FreeStyle Libre 1 and 2 intermittently scanned CGM (is-CGM) devices in people with type 1 diabetes receiving multiple daily insulin injections in Denmark.

Materials And Methods: The analysis was performed using the IQVIA Core Diabetes Model, which associates rt-CGM use with glycated haemoglobin reductions of 0.6% and 0.

View Article and Find Full Text PDF
Article Synopsis
  • The study analyzes the error introduced when using the Kaplan-Meier estimate for survival data that is not fully mature, focusing on how different maturity levels affect long-term life expectancy projections in economic evaluations.
  • It compared data from phase 3 trials reporting overall survival (OS) with 70% maturity to artificially truncated data sets representing lower maturities (30% and 50%) using various statistical methods.
  • Results indicated that as OS maturity increases, the accuracy of life expectancy estimates improves, emphasizing the importance of using mature data when developing economic models.
View Article and Find Full Text PDF

Objective: To evaluate the impact of CamAPS FX hybrid closed-loop (HCL) automated insulin delivery in very young children with type 1 diabetes (T1D) on caregivers' well-being, fear of hypoglycemia, and sleepiness.

Research Design And Methods: We conducted a multinational, open-label, randomized crossover study. Children (age 1-7 years) with T1D received treatment for two 4-month periods in random order, comparing HCL with sensor augmented pump (control).

View Article and Find Full Text PDF

Introduction: Real-time continuous glucose monitoring (rt-CGM) involves the measurement and display of glucose concentrations, potentially improving glucose control among insulin-treated patients with type 2 diabetes (T2D). The present analysis aimed to conduct a cost-effectiveness analysis of rt-CGM versus self-monitoring of blood glucose (SMBG) based on a USA retrospective cohort study in insulin-treated people with T2D adapted to the UK.

Methods: Long-term costs and clinical outcomes were estimated using the CORE Diabetes Model, with clinical input data sourced from a retrospective cohort study.

View Article and Find Full Text PDF

This article gives a personal, historical, account of the impact of the COVID-19 pandemic on transplantation services. The content is based on discussions held at two webinars in November 2020, at which kidney transplantation experts from prestigious institutions in Europe and the United States reflected on how the pandemic affected working practices. The group discussed adaptations to clinical care (i.

View Article and Find Full Text PDF

Objectives: Extrapolation is often required to inform cost-effectiveness (CE) evaluations of immune-checkpoint inhibitors (ICIs) since survival data from pivotal clinical trials are seldom complete. The objectives of this study were to evaluate the accuracy of estimates of long-term overall survival (OS) predicted in French CE assessment reports of ICIs, and to identify models presenting the best fit to the observed long-term survival data.

Methods: A systematic review of French assessment reports of ICIs in the metastatic setting since inception until May 2020 was performed.

View Article and Find Full Text PDF

Introduction: Real-time continuous glucose monitoring (rt-CGM) allows patients with diabetes to adjust insulin dosing, potentially improving glucose control. This study aimed to compare the long-term cost-effectiveness of the Dexcom G6 rt-CGM device versus self-monitoring of blood glucose (SMBG) and flash glucose monitoring (FGM) in Australia in people with type 1 diabetes (T1D).

Methods: Long-term costs and clinical outcomes were estimated using the CORE Diabetes Model.

View Article and Find Full Text PDF

Introduction: Hybrid closed loop (HCL) insulin pump systems and intermittently scanned continuous glucose monitoring (IS-CGM) are increasingly used by individuals with type 1 diabetes (T1D). The aim of the analysis was to compare the long-term cost-effectiveness of the MiniMed 670G HCL system versus IS-CGM plus multiple daily injections of insulin (MDI) or continuous subcutaneous insulin infusion (CSII) in adults with T1D in the Netherlands.

Methods: The analysis was performed using the IQVIA CORE Diabetes Model with clinical input data sourced from observational studies.

View Article and Find Full Text PDF

Introduction: Early detection and treatment of cardiogenic shock (CS) is crucial to avoid irreparable multiorgan damage and mortality. Impella CP is a novel temporary mechanical circulatory support (MCS) device associated with greater hemodynamic support and significantly fewer device-related complications compared with other MCS devices, e.g.

View Article and Find Full Text PDF

Background: The possible advantage of hybrid closed-loop therapy (i.e., artificial pancreas) over sensor-augmented pump therapy in very young children with type 1 diabetes is unclear.

View Article and Find Full Text PDF

Background: The Dexcom G6 real-time continuous glucose monitoring (RT-CGM) system is one of the most sophisticated RT-CGM systems developed to date and became available in Canada in 2019. A health economic analysis was performed to determine the long-term cost-effectiveness of the Dexcom G6 RT-CGM system versus SMBG in adults with type 1 diabetes (T1D) in Canada.

Methods: The analysis was performed using the IQVIA Core Diabetes Model.

View Article and Find Full Text PDF

Aims: The MiniMed 670 G insulin pump system is the first commercially available hybrid closed-loop (HCL) insulin delivery system and clinical studies have shown that this device is associated with incremental benefits in glycemic control relative to continuous subcutaneous insulin infusion (CSII) with or without continuous glucose monitoring (CGM). The aim was to evaluate the long-term cost-effectiveness of the MiniMed 670 G system versus CSII alone in people with type 1 diabetes (T1D) in the UK.

Materials And Methods: Cost-effectiveness analysis was performed using the IQVIA CORE Diabetes Model.

View Article and Find Full Text PDF

Introduction: Diabetes management in very young children remains challenging. Glycaemic targets are achieved at the expense of high parental diabetes management burden and frequent hypoglycaemia, impacting quality of life for the whole family. Our objective is to assess whether automated insulin delivery can improve glycaemic control and alleviate the burden of diabetes management in this particular age group.

View Article and Find Full Text PDF

Aim: Cardiogenic shock (CS), if not diagnosed and treated rapidly, can lead to irreversible multiorgan damage and death. An economic analysis was conducted to determine the budget impact of the introduction of Impella 5.0, a mechanical circulatory support (MCS) device that directly unloads the left ventricle, into clinical practice in patients with left ventricular CS in France.

View Article and Find Full Text PDF

Introduction: The aim was to determine the long-term cost-effectiveness of the Dexcom G6 real-time continuous glucose monitoring (RT-CGM) system versus self-monitoring of blood glucose (SMBG) in adults with type 1 diabetes (T1D) in France.

Methods: The analysis was performed using the IQVIA Core Diabetes Model and utilized clinical input data from the DIAMOND clinical trial in adults with T1D. Simulated patients were assumed to have a mean baseline HbA1c of 8.

View Article and Find Full Text PDF

Introduction: The aim of the current study is to estimate the cost-effectiveness of adjuvant treatment with nivolumab relative to clinically relevant comparators in adult patients with melanoma with lymph node involvement or metastatic disease who have undergone complete resection from a French societal perspective.

Methods: The comparators were observation, low-dose interferon and pembrolizumab. A subgroup analysis was carried out in patients with BRAF mutation, adding dabrafenib plus trametinib.

View Article and Find Full Text PDF

Objective: France has included health economic assessment (HEA) as an official criterion for innovative drug pricing since 2013. Until now, no cost-effectiveness threshold (CET) has been officially proposed to qualify incremental cost-effectiveness ratios (ICERs). Although the French health authorities have publicly expressed the need for such reference values, previous initiatives to determine these have failed.

View Article and Find Full Text PDF