Fiber-optic dynamic interrogators, which use periodic frequency scanning, actually sample a time-varying measurand on a time grid. Commonly, however, the sampled values are reported on a time grid, synchronized with the periodic scanning. It is the novel and noteworthy message of this paper that this artificial assignment may give rise to significant distortions in the recovered signal.
View Article and Find Full Text PDFA distributed and dynamic strain sensing system based on frequency-scanning phase-sensitive optical time domain reflectometry is proposed and demonstrated. By utilizing an RF pulse scheme with a fast arbitrary waveform generator, a train of optical pulses covering a large range of different optical frequencies, short pulse width, and high extinction ratio is generated. Also, a Rayleigh-enhanced fiber is used to eliminate the need for averaging, allowing single-shot operation.
View Article and Find Full Text PDFIt has been recently shown that in stimulated Brillouin amplification (pulsed pump & CW probe) the line-shape of the normalized logarithmic Brillouin Gain Spectrum (BGS) broadens with increasing gain. Most pronounced for short pump pulses, a linewidth increase of ~3 MHz (~1.5 MHz) per dB of additional gain was observed for a pump pulse width of 15 ns (30 ns), respectively.
View Article and Find Full Text PDF