Background: An estimated 10,000 Americans suffer cervical spine injuries each year. More than 800,000 cervical spine radiographs (CSR) are ordered annually. The human and healthcare costs associated with these injuries are enormous especially when diagnosis is delayed.

View Article and Find Full Text PDF

Background: Data from our previous studies indicate that Taser X26 stun devices can acutely alter cardiac function in swine. We hypothesized that most transcardiac discharge vectors would capture ventricular rhythm, but that other vectors, not traversing the heart, would fail to capture the ventricular rhythm.

Methods: Using an Institutional Animal Care and Use Committee (IACUC) approved protocol, four Yorkshire pigs (25-36 kg) were anesthetized, paralyzed with succinylcholine (2 mg/kg), and then exposed to 10 second discharges from a police-issue Taser X26.

View Article and Find Full Text PDF

Objective: Electromuscular incapacitation (EMI) devices are being used and evaluated by both military and law enforcement agencies. Although the gross muscular response is obvious, physiological responses to these devices are poorly understood. We hypothesized that the intense, repetitive, muscle contractions evoked by EMI devices would cause dose-dependent metabolic acidosis, accompanied by neuromuscular or cardiac injury.

View Article and Find Full Text PDF

Objectives: Data from the authors and others suggest that TASER X26 stun devices can acutely alter cardiac function in swine. The authors hypothesized that TASER discharges degrade cardiac performance through a mechanism not involving concurrent acidosis.

Methods: Using an Institutional Animal Care and Use Committee (IACUC)-approved protocol, Yorkshire pigs (25-71 kg) were anesthetized, paralyzed with succinylcholine (SCh; 2 mg/kg), and then exposed to two 40-second discharges from a TASER X26 with a transcardiac vector.

View Article and Find Full Text PDF

Background: Very little objective laboratory data are available describing the physiologic effects of stun guns or electromuscular incapacitation devices (EIDs). Unfortunately, there have been several hundred in-custody deaths, which have been temporally associated with the deployment of these devices. Most of the deaths have been attributed to specific cardiac and metabolic effects.

View Article and Find Full Text PDF

Background: Stun guns or electromuscular incapacitation devices (EMIs) generate between 25,000 and 250,000 V and can be discharged continuously for as long as 5 to 10 min. In the United States, over 200,000 individuals have been exposed to discharges from the most common type of device used. EMI devices are being used increasingly despite a lack of objective laboratory data describing the physiological effects and safety of these devices.

View Article and Find Full Text PDF

Background: Little objective laboratory data are available describing the physiologic effects of stun guns or electromuscular incapacitation (EMI) devices, but increasing morbidity and even deaths are associated with their use. We hypothesized that exposure to EMI discharges in a model animal system would induce clinically significant acidosis and cardiac arrhythmia.

Methods: Ten Yucatan mini-pigs, six experimental and four sham controls, were anesthetized with ketamine, xylazine, and glycopyrrolate.

View Article and Find Full Text PDF

Gunshot wounds that traverse the mediastinum frequently cause serious injury to the cardiac, vascular, pulmonary, and digestive structures contained within. Most patients present with unstable vital signs signifying the need for emergency operation. An occasional patient will present with stable vital signs.

View Article and Find Full Text PDF