Publications by authors named "Rousselle S"

Anterior cruciate ligament reconstruction (ACLR) is one of the more common procedures performed worldwide and perhaps the most widely studied construct in orthopedic literature. Interference screws are reliable and frequently used for ligament reconstruction, providing rigid fixation and facilitates graft incorporation allowing for the physiologic loads of early rehabilitation. The purpose of this study was to determine the bio-integration profile and quality of soft tissue graft when using mineral fiber-reinforced screws in an ACLR interference model.

View Article and Find Full Text PDF

Nonclinical implantation studies are a common and often critical step for medical device safety assessment in the bench-to-market pathway. Nonclinical implanted medical devices or drug-device combination products require complex macroscopic and microscopic pathology evaluations due to the physical presence of the device itself and unique tissue responses to device materials. The Medical Device Implant Site Evaluation working group of the Society of Toxicologic Pathology's (STP) Scientific and Regulatory Policy Committee (SRPC) was tasked with reviewing scientific, technical, and regulatory considerations for these studies.

View Article and Find Full Text PDF

The aim of the study was to evaluate a balloon expandable transcatheter heart valve (THV) system (Myval) at 6-month follow-up in ovine banding model. Eleven THV systems were implanted via carotid approach. There were 2 procedure-related deaths and 2 premature deaths.

View Article and Find Full Text PDF

The study assessed chronic myocardial, coronary and systemic effects of intracoronary supersaturated oxygen (SSO) therapy. Left anterior descending coronary arteries of 40 swine were stented and randomized to 90-min selective intracoronary infusion of SSO (pO 760-1000 mmHg) or normoxemic saline. In 20 out of 40 animals, SSO delivery followed a 60-min balloon occlusion to induce myocardial infarction (MI).

View Article and Find Full Text PDF

Significance: Intravascular photoacoustic (IVPA) imaging can identify native lipid in atherosclerotic plaques in vivo. However, the large number of laser pulses required to produce 3D images is a safety concern that has not been fully addressed.

Aim: We aim to evaluate if irradiation at wavelengths and dosages relevant to IVPA imaging causes target vessel damage.

View Article and Find Full Text PDF

One of the challenging aspects of minimal invasive surgery (MIS) is intracorporal suturing, which can be significantly time-consuming. Therefore, there is a rising need for devices that can facilitate the suturing procedure in MIS. Su2ura Approximation Device (Su2ura Approximation) is a novel device developed to utilize the insertion of anchors threaded with stitches to allow a single action placement of a suture.

View Article and Find Full Text PDF

Re-endothelialization of vascular lumen after endovascular procedures is a critical healing milestone and is subjected to routine pathological evaluation during preclinical safety assessment of new cardiovascular devices. Gross evaluation, microscopic evaluation, and scanning electron microscopy (SEM) are the methods of choice for evaluation of vascular surfaces. In this article, we present a new digital imaging approach of surface topography herein referred to as topographical digital microscopy (TDM) that is able to meet the objectives of endovascular healing assessment in a single instrumental platform combined with the same sample preparation techniques as for histology or SEM.

View Article and Find Full Text PDF

With advancements in whole slide imaging technology and improved understanding of the features of pathologist workstations required for digital slide evaluation, many institutions are investigating broad digital pathology adoption. The benefits of digital pathology evaluation include remote access to study or diagnostic case materials and integration of analysis and reporting tools. Diagnosis based on whole slide images is established in human medical pathology, and the use of digital pathology in toxicologic pathology is increasing.

View Article and Find Full Text PDF

Objective: This study aimed to evaluate the pharmacokinetic profile and tissue effects of everolimus delivered into arterial wall using biodegradable nanospheres.

Background: Delivery of everolimus into the arterial wall is challenging due to its low-lipophilic profile.

Methods: A pharmacokinetic study included 28 porcine coronary arterial segments initially injured with balloon angioplasty followed by the local delivery of everolimus encapsulated in nanospheres (EEN) via injection through a microporous delivery catheter.

View Article and Find Full Text PDF

Dura mater defects are a common problem following neurosurgery. Dural grafts are used to repair these defects; among them are biodegradable polymeric synthetic grafts. ArtiFascia is a novel synthetic and fibrous Dural graft, composed of poly(l-lactic-co-caprolactone acid) (PLCL) and poly(d-lactic-co-caprolactone acid).

View Article and Find Full Text PDF

Intravascular imaging has emerged as a valuable tool for the treatment of coronary and peripheral artery disease; however, no solution is available for safe and reliable use in the tortuous vascular anatomy of the brain. Endovascular treatment of stroke is delivered under image guidance with insufficient resolution to adequately assess underlying arterial pathology and therapeutic devices. High-resolution imaging, enabling surgeons to visualize cerebral arteries' microstructure and micron-level features of neurovascular devices, would have a profound impact in the research, diagnosis, and treatment of cerebrovascular diseases.

View Article and Find Full Text PDF

Surgical site infections (SSIs) are a common surgical-related complication. To avoid these complications, a new biodegradable polymer-lipid encapsulation matrix that provides controlled release of doxycycline (doxycycline/polymer-lipid encapsulation matrix [D-PLEX]) has been developed. The aim of this comprehensive study was to evaluate the potential safety of D-PLEX in abdominal surgical site.

View Article and Find Full Text PDF

Aims: Peripheral arteries are constantly exposed to deformation (elongation, twisting, shortening, compression) making bioresorbable scaffolds (BRS) a potentially attractive therapeutic alternative to metallic stents. We conducted a long-term pilot preclinical study of a novel sirolimus-eluting BRS in peripheral arteries.

Methods And Results: Fourteen BRS were deployed in iliofemoral arteries of seven healthy Yucatan miniswine and examined with imaging, pharmacokinetic, histopathologic, and polymer degradation techniques at 0, 30, 90, 180 days, 1, 2, and 3.

View Article and Find Full Text PDF

Purpose: To evaluate the patency, cellular response, and thrombogenicity of a novel vascular stent graft.

Materials And Methods: Test stent grafts, incorporating luminal spun polytetrafluoroethylene and a nonpermeable fluoropolymer layer, and control stent grafts, constructed of permeable expanded polytetrafluoroethylene, were implanted in the external iliac arteries of 14 adult sheep with a median weight of 73.4 kg ranging from 60.

View Article and Find Full Text PDF

Purpose: To compare the safety and efficacy of an absorbable inferior vena cava (IVC) filter and a benchmark IVC filter in a porcine model.

Materials And Methods: A randomized controlled Good Laboratory Practice study was performed in Domestic Yorkshire cross swine. Sixteen swine were implanted with an absorbable IVC filter (test device; Adient Medical, Pearland, Texas); 8 were implanted with a benchmark metal IVC filter (control device; Cook Medical, Bloomington, Indiana).

View Article and Find Full Text PDF

Saphenous vein graft (SVG) failure rates are unacceptably high, and external mechanical support may improve patency. We studied the histologic remodeling of a conformal, electrospun, polydimethylsiloxane-based polyether urethane external support device for SVGs and evaluated graft structural evolution in adult sheep to 2 years. All sheep (N = 19) survived to their intended timepoints, and angiography showed device-treated SVG geometric stability over time (30, 90, 180, 365, or 730 days), with an aggregated graft patency rate of 92%.

View Article and Find Full Text PDF

Histology of medical devices poses a variety of unique challenges. Comprehensive histologic assessment of medical devices often requires spatial context and high-quality retention of the device-tissue interface. However, the composition of many medical devices is often not amenable to traditional paraffin embedding and thus alternative specialized methodologies such as hard resin embedding must be used.

View Article and Find Full Text PDF

Cardiac electrophysiology utilizes nonimplantable, catheter-based devices for diagnosis and treatment of arrhythmias as well as electroanatomical mapping of cardiac chambers. Gross pathology and histopathological assessments in preclinical studies play critical roles in determining the safety and efficacy of cardiac ablation systems used to treat tachyarrhythmias. The pathologist must assess ablation sites, adjacent structures and organs, and downstream organs to characterize the effects of the ablation treatment and determine whether adverse local reactions, collateral injury, or downstream thromboembolism are present.

View Article and Find Full Text PDF

Bioabsorbable implants can be advantageous for certain surgical tissue bioengineering applications and implant-assisted tissue repair. They offer the obvious benefits of nonpermanence and eventual restoration of the native tissue's biomechanical and immunological properties, while providing a structural scaffold for healing and a route for additional therapies (i.e.

View Article and Find Full Text PDF

Medical devices comprise a wide variety of therapeutic tools aimed at modulating or restoring organ function. Devices may be implanted or activated temporally or permanently, and are used to deliver a wide range of therapies such as drugs, electrical stimulation, laser, thermal energy, offer mechanical support, and restore sensory functions. Technological advancements allow improvement and development of devices at a rapid pace.

View Article and Find Full Text PDF

Objectives: We aimed to investigate the safety of radiofrequency (RF)-renal denervation (RDN) on branch renal arteries (RAs) in a porcine model.

Background: The efficacy of RF-RDN was enhanced by treatment of the branch RA, in addition to the main RA. However, there are concerns regarding the safety of RF-RDN on branch RA because of their smaller diameter and proximity to the kidney.

View Article and Find Full Text PDF

Nitinol stents are widely used for the treatment of peripheral arterial diseases in lower extremity arteries and have shown different clinical outcomes depending on implanted arterial segments. We aimed to compare histopathological responses to nitinol stents in femoral artery (FA) with those in femoropopliteal artery (FPA), which is markedly bended during knee flexion. A single nitinol stent was implanted in FA and FPA of 21 domestic swine.

View Article and Find Full Text PDF

Introduction: Several renal denervation (RDN) systems are currently under investigation for treatment of hypertension by ablation of renal sympathetic nerves. The procedural efficacy of devices, however, is variable and incompletely understood. This study aimed at investigating procedural and anatomical predictors of RDN efficacy by comparing two radiofrequency catheter systems in a porcine model.

View Article and Find Full Text PDF

Transcatheter prosthetic valves are heralding a new era in interventional cardiology and affording real therapeutic options to categories of patients currently medically disqualified, namely the elderly and higher risk individuals. An increasing variety of novel artificial valve designs and delivery systems are being tested preclinically. Cardiologists and surgeons are generally well-equipped to assess deliverability and function; however, methods for pathological evaluation of animals enrolled in transcatheter valve implant testing are scant, often vague, and far from consensual.

View Article and Find Full Text PDF

Background: Cerebrospinal fluid (CSF) leaks increase postoperative risk for complication, likelihood of reoperation, and costs.

Objective: To investigate a novel, self-adhering polyethylene glycol-coated collagen pad (PCC) as a dural substitute relative to Duragen XS (DGX; Integra LifeSciences Corporation, Plainsboro, New Jersey) and as a dural sealant relative to Tachosil (Takeda Austria GmbH, Linz, Austria), a fibrinogen and thrombin-coated collagen pad (FTC).

Methods: A canine supratentorial durotomy surgical model was used to investigate the safety and efficacy of PCC.

View Article and Find Full Text PDF