There has been an increasing interest in atom probe tomography (APT) to characterize hydrated and biological materials. A major benefit of APT compared to microscopy techniques more commonly used in biology is its combination of outstanding three-dimensional (3D) spatial resolution and mass sensitivity. APT has already been successfully used to characterize biominerals, revealing key structural information at the atomic scale, however there are many challenges inherent to the analysis of soft hydrated materials.
View Article and Find Full Text PDFNew high-resolution imaging methods for biological samples such as atom probe tomography (APT), facilitated by the invention of laser-pulsed atom probes and cryo-transfer procedures, have recently emerged. However, ensuring the vitreous state of the fabricated aqueous needle-shaped APT samples remains a challenge despite it being crucial for characterizing biomolecules such as proteins and cellular architectures in their near-native state. Our work investigated three potential approaches: (1) open microcapillary (OMC) method, (2) high-pressure freezing method (HPF), and (3) graphene encapsulation method.
View Article and Find Full Text PDFA new method for imaging liquid specimens with atom probe tomography (APT) is proposed by introducing graphene encapsulation. By tuning the encapsulation speed and the number of encapsulations, controllable volumes of liquid can be encapsulated on a pre-sharpened specimen tip, with the end radius less than 75 nm to allow field ionization and evaporation. Encapsulation of liquid has been confirmed by using various characterization techniques, including electron microscopy and stimulated emission depletion microscopy.
View Article and Find Full Text PDFUnravelling the three-dimensional structures and compositions of biological macromolecules sheds light on their functions and also contributes to the design of future biochemical compounds and processes. Atom probe tomography (APT) is demonstrated in this research as a new and effective approach to explore the structure and chemical composition of a single protein in the hydrated state. By introducing graphene encapsulation, proteins in solution can be immobilized on a metal specimen tip, with an end radius in the range of 50 nm to allow field ionization and evaporation.
View Article and Find Full Text PDFWe present a novel approach for analysis of low-conductivity and insulating materials with conventional pulsed-voltage atom probe tomography (APT), by incorporating an ultrathin metallic coating on focused ion beam prepared needle-shaped specimens. Finite element electrostatic simulations of coated atom probe specimens were performed, which suggest remarkable improvement in uniform voltage distribution and subsequent field evaporation of the insulated samples with a metallic coating of approximately 10nm thickness. Using design of experiment technique, an experimental investigation was performed to study physical vapor deposition coating of needle specimens with end tip radii less than 100nm.
View Article and Find Full Text PDFEmergence of multidrug resistant Gram-negative bacteria has caused a global health crisis and last-line class of antibiotics such as polymyxins are increasingly used. The chemical composition at the cell surface plays a key role in antibiotic resistance. Unlike imaging the cellular ultrastructure with well-developed electron microscopy, the acquisition of a high-resolution chemical map of the bacterial surface still remains a technological challenge.
View Article and Find Full Text PDFWhilst atom probe tomography (APT) is a powerful technique with the capacity to gather information containing hundreds of millions of atoms from a single specimen, the ability to effectively use this information creates significant challenges. The main technological bottleneck lies in handling the extremely large amounts of data on spatial-chemical correlations, as well as developing new quantitative computational foundations for image reconstruction that target critical and transformative problems in materials science. The power to explore materials at the atomic scale with the extraordinary level of sensitivity of detection offered by atom probe tomography has not been not fully harnessed due to the challenges of dealing with missing, sparse and often noisy data.
View Article and Find Full Text PDFAtom probe tomography (APT) has been used to investigate the surface and sub-surface microstructures of aluminum alloy 2024 (AA2024) in the T3 condition (solution heat treated, cold worked, and naturally aged to a substantially stable condition). This study revealed surface Cu enrichment on the alloy matrix, local chemical structure around a dispersoid Al20Mn3Cu2 particle including a Cu-rich particle and S-phase particle on its external surface. Moreover, there was a significant level of hydrogen within the dispersoid, indicating that it is a hydrogen sink.
View Article and Find Full Text PDFMicroscopy encompasses a wide variety of forms and scales. So too does the array of simulation techniques developed that correlate to and build upon microstructural information. Nevertheless, a true nexus between microscopy and atomistic simulations is lacking.
View Article and Find Full Text PDFA multi-scale investigation of twin bundles in Fe-22Mn-0.6C (wt%) twinning-induced plasticity steel after tensile deformation has been carried out by truly correlative means; using electron channelling contrast imaging combined with electron backscatter diffraction, high-resolution secondary ion mass spectrometry, scanning transmission electron microscopy, and atom probe tomography on the exact same region of interest in the sample. It was revealed that there was no significant segregation of Mn or C to the twin boundary interfaces.
View Article and Find Full Text PDFThe generalized multicomponent short-range order (GM-SRO) parameter has been adapted for the characterization of short-range order within the highly chemically and spatially resolved three-dimensional atomistic images provided by the microscopy technique of atom-probe tomography (APT). It is demonstrated that, despite the experimental limitations of APT, in many cases the GM-SRO results derived from APT data can provide a highly representative description of the atomic scale chemical arrangement in the original specimen. Further, based upon a target set of the GM-SRO parameters, measured from APT experiments, a Monte Carlo algorithm was utilized to simulate statistically equivalent atomistic systems which, unlike APT data, are complete and lattice based.
View Article and Find Full Text PDFProgress in the reconstruction for atom probe tomography has been limited since the first implementation of the protocol proposed by Bas et al. in 1995. This approach and those subsequently developed assume that the geometric parameters used to build the three-dimensional atom map are constant over the course of an analysis.
View Article and Find Full Text PDFAtom probe tomography (APT) represents a significant step toward atomic resolution microscopy, analytically imaging individual atoms with highly accurate, though imperfect, chemical identity and three-dimensional (3D) positional information. Here, a technique to retrieve crystallographic information from raw APT data and restore the lattice-specific atomic configuration of the original specimen is presented. This lattice rectification technique has been applied to a pure metal, W, and then to the analysis of a multicomponent Al alloy.
View Article and Find Full Text PDF