Objective: To study the safety and efficacy of algorithmically controlled electroporation (ACE) against spontaneous equine melanoma.

Methods: A custom temperature sensing coaxial electrode was paired with a high voltage pulse generation system with integrated temperature feedback controls. Computational modeling and ex vivo studies were conducted to evaluate the system's ability to achieve and maintain target temperatures.

View Article and Find Full Text PDF

Introduction: Integrated time nanosecond pulse irreversible electroporation (INSPIRE) is a novel tumor ablation modality that employs high voltage, alternating polarity waveforms to induce cell death in a well-defined volume while sparing the underlying tissue. This study aimed to demonstrate the efficacy of INSPIRE against spontaneous melanoma in standing, awake horses.

Methods: A custom applicator and a pulse generation system were utilized in a pilot study to treat horses presenting with spontaneous melanoma.

View Article and Find Full Text PDF

Objective: This study sought to investigate a novel strategy using temperature-controlled delivery of nanosecond pulsed electric fields as an alternative to the 50-100 microsecond pulses used for irreversible electroporation.

Methods: INSPIRE treatments were carried out at two temperatures in 3D tumor models using doses between 0.001 s and 0.

View Article and Find Full Text PDF

Expanding the volume of an irreversible electroporation treatment typically necessitates an increase in pulse voltage, number, duration, or repetition. This study investigates the addition of polyethylenimine nanoparticles (PEI-NP) to pulsed electric field treatments, determining their combined effect on ablation size and voltages. U118 cells in an in vitro 3D cell culture model were treated with one of three pulse parameters (with and without PEI-NPs) which are representative of irreversible electroporation (IRE), high frequency irreversible electroporation (H-FIRE), or nanosecond pulsed electric fields (nsPEF).

View Article and Find Full Text PDF

Objective: To evaluate the effect of a closed-loop temperature based feedback algorithm on ablative outcomes for pulsed electric field treatments.

Methods: A 3D tumor model of glioblastoma was used to assess the impact of 2 μs duration bipolar waveforms on viability following exposure to open and closed-loop protocols. Closed-loop treatments evaluated transient temperature increases of 5, 10, 15, or 22 °C above baseline.

View Article and Find Full Text PDF

Electro-thermal therapy (ETT) is a new cancer treatment modality which combines the use of high voltage pulsed electric fields, dynamic energy delivery rates, and closed loop thermal control algorithms to rapidly and reproducibly create focal ablations. This study examines the ablative potential and profile of pulsed electric field treatments delivered in conjunction with precise temperature control algorithms. An ex vivo perfused liver model was utilized to demonstrate the capability of 5000 V 2 μs duration bipolar electrical pulses and dynamic temperature control algorithms to produce ablations.

View Article and Find Full Text PDF

Irreversible electroporation (IRE) is generally considered to be a non-thermal ablation modality. This study was designed to examine the relative effect of temperature on IRE ablation sizes for equivalent dose treatments with constitutive pulses between 1 and 100 µs. 3D in-vitro brain tumor models maintained at 10 °C, 20 °C, 30 °C, or 37 °C were exposed to 500 V treatments using a temperature control algorithm to limit temperature increases to 5 °C.

View Article and Find Full Text PDF

Thermal tissue injury is an unintended consequence in current irreversible electroporation treatments due to the induction of Joule heating during the delivery of high voltage pulsed electric fields. In this study active temperature control measures including internal electrode cooling and dynamic energy delivery were investigated as a process for mitigating thermal injury during treatment. Ex vivo liver was used to examine the extent of thermal injury induced by 5000 V treatments with delivery rates up to five times faster than current clinical practice.

View Article and Find Full Text PDF

Electroporation is a bioelectric phenomenon used to deliver target molecules into cells in vitro and irreversible electroporation (IRE) is an emerging cancer therapy used to treat inoperable tumors in situ. These phenomena are generally considered to be non-thermal in nature. In this study, a 3D tumor model was used to investigate the correlation between temperature and the effectiveness of standard clinical IRE and high frequency (H-FIRE) protocols.

View Article and Find Full Text PDF

Purpose: To investigate if high-frequency irreversible electroporation (H-FIRE) treatments can be delivered at higher voltages and with greater energy delivery rates than currently implemented in clinical irreversible electroporation protocols.

Materials And Methods: Treatments using 3,000 V and 5,000 V were administered to mechanically perfused ex vivo porcine liver via a single applicator and grounding pad (A+GP) as well as a 4-applicator array (4AA). Integrated energized times (IET) 0.

View Article and Find Full Text PDF

Objective: Picosecond pulse electric fields (psPEF) have the potential to elicit functional changes in mammalian cells in a non-contact manner. Such electro-manipulation of pluripotent and multipotent cells could be a tool in both neural interface and tissue engineering. Here, we describe the potential of psPEF in directing neural stem cells (NSCs) gene expression, metabolism, and proliferation.

View Article and Find Full Text PDF

A dielectrically loaded wideband rod antenna has been studied as a pulse delivery system to subcutaneous tissues. Simulation results applying 100 ps electrical pulse show that it allows us to generate critical electric field for biological effects, such as brain stimulation, in the range of several centimeters. In order to reach the critical electric field for biological effects, which is approximately 20 kV/cm, at a depth of 2 cm, the input voltage needs to be 175 kV.

View Article and Find Full Text PDF