Publications by authors named "Roseline Re"

Carbohydrate counting (CC) and meal announcements, before eating, introduce a significant burden for individuals managing type 1 diabetes (T1D). An automated insulin delivery system with automatic bolusing that eliminates the need for CC and premeal bolusing (i.e.

View Article and Find Full Text PDF

Aims: To reassess the 6-month efficacy and to assess the 12-month sustained efficacy of the MiniMed™ 780G advanced hybrid closed-loop automated insulin delivery (AID) system compared to multiple daily injections plus intermittently scanned glucose monitoring (MDI+isCGM) in people with type 1 diabetes not meeting glucose targets.

Methods: The ADAPT study was a prospective, multicentre, open-label, randomized control trial in people with type 1 diabetes, with a glycated haemoglobin (HbA1c) concentration of at least 8.0% (64 mmol/mol), on MDI+isCGM therapy.

View Article and Find Full Text PDF

Background: This analysis reports the findings from a predefined exploratory cohort (cohort B) from the ADAPT (ADvanced Hybrid Closed Loop Study in Adult Population with Type 1 Diabetes) study. Adults with type 1 diabetes (T1D) with suboptimal glucose control were randomly allocated to an advanced hybrid closed-loop (AHCL) system or multiple daily injections of insulin (MDI) plus real-time continuous glucose monitoring (RT-CGM).

Methods: In this prospective, multicenter, exploratory, open-label, randomized controlled trial, 13 participants using MDI + RT-CGM and with HbA1c ≥8.

View Article and Find Full Text PDF

Background: Adults with type 1 diabetes who are treated with multiple daily injections of insulin plus intermittently scanned continuous glucose monitoring (isCGM) can have suboptimal glucose control. We aimed to assess the efficacy of an advanced hybrid closed loop (AHCL) system compared with such therapy in this population.

Methods: The Advanced Hybrid Closed Loop Study in Adult Population with Type 1 Diabetes (ADAPT) trial is a prospective, multicentre, open-label, randomised controlled trial that involved 14 centres in three European countries (France, Germany, and the UK).

View Article and Find Full Text PDF

Introduction: For many people with type 1 diabetes who struggle to achieve glycaemic control with multiple daily injections of insulin (MDI) plus self-monitoring of blood glucose, MDI plus intermittently scanned continuous glucose monitoring (IS-CGM) or real-time continuous glucose monitoring (RT-CGM), or insulin administration using insulin pump therapy represent optimised care in many regions. Through technological advances an advanced hybrid closed loop (AHCL) system has been developed; studies of incremental effects relative to MDI plus IS-CGM are lacking.

Methods And Analysis: The Advanced Hybrid Closed Loop study in Adult Population with Type 1 Diabetes (ADAPT) study is a multinational, prospective, open-label, confirmatory and exploratory randomised controlled trial to examine outcomes with the MiniMed 670G version 4.

View Article and Find Full Text PDF

Background: Hypoglycaemia unawareness and severe hypoglycaemia can increase fear of hypoglycaemia and the risk of subsequent hypoglycaemic events. We aimed to assess the safety and efficacy of insulin pump therapy with integrated continuous glucose monitoring (CGM) and a suspend-before-low feature (Medtronic MiniMed 640G with SmartGuard) in hypoglycaemia-prone adults with type 1 diabetes.

Methods: SMILE was an open-label randomised controlled trial done in people aged 24-75 years with type 1 diabetes for 10 years or longer, HbA values of 5·8-10·0% (40-86 mmol/mol), and at high risk of hypoglycaemia (recent severe hypoglycaemia or hypoglycaemia unawareness defined by a Clarke or Gold score ≥4).

View Article and Find Full Text PDF