Publications by authors named "Rosado L"

Managing the diverse waste fractions generated by households presents a significant environmental and logistical challenge. One widely adopted solution is waste sorting at the source, where residents are required to separate their waste into designated containers. The success of this strategy depends on the extent of adoption and the behaviour of residents.

View Article and Find Full Text PDF
Article Synopsis
  • The study assessed the perceptions and willingness of Indiana dental hygienists to administer vaccines, highlighting their potential role in improving immunization access.
  • Most respondents had positive views on vaccines, with a significant majority expressing willingness to receive training and administer vaccines, particularly in dental offices.
  • The main challenges identified were related to education and training, along with a general discomfort in administering vaccines to children compared to adults.
View Article and Find Full Text PDF

This paper presents the development of a novel eddy current array (ECA) system for real-time, layer-by-layer quality control in powder bed fusion (PBF) additive manufacturing. The system is integrated into the recoater of a PBF machine to provide spatially resolved electrical conductivity imaging of the manufactured part. The system features an array of 40 inductive sensors spaced at 1 mm pitch and is capable of performing a full array readout every 0.

View Article and Find Full Text PDF

Purpose: To critically appraise and summarize the potential of linear and/or volumetric dimensions of the maxillary sinuses obtained with cone-beam and multi-slice computed tomography.

Methods: A bibliographic search was conducted in seven databases in August 2023. Cross-sectional retrospective studies using linear and volumetric measurements of the maxillary sinuses obtained with cone-beam and multi-slice computed tomography for sex estimation and presenting numerical estimation data were included.

View Article and Find Full Text PDF

Purpose: This study examined the influence of a metal artifact reduction (MAR) tool, sharpening filters, and their combination on the diagnosis of vertical root fracture (VRF) in teeth with metallic posts using cone-beam computed tomography (CBCT).

Materials And Methods: Twenty single-rooted human premolars - 9 with VRF and 11 without - were individually placed in a human mandible. A metallic post composed of a cobalt-chromium alloy was inserted into the root canal of each tooth.

View Article and Find Full Text PDF

Background: Per the College of American Pathologist's National Breast Fine Needle Aspiration Biopsy (FNAB) Practice Survey, ∼40% of laboratories use liquid-based cytology (LBC) for breast FNAB. The reproducibility of the International Academy of Cytology Yokohama System (YS) for reporting breast FNAB on LBC was explored.

Design: Breast FNAB specimens submitted as LBC only (all ThinPrep) between January 2017 and January 2021 were retrieved.

View Article and Find Full Text PDF
Article Synopsis
  • - The study investigated how different metal post materials, tooth locations, and metal artifact reduction (MAR) affect the diagnosis of vertical root fractures (VRF) using cone beam computed tomography (CBCT) on a sample of unirradicular premolars.
  • - CBCT scans were analyzed by five evaluators, with findings showing that while the overall diagnostic values were unaffected, the sensitivity for detecting VRF improved with MAR, particularly in the anterior and for specific materials in the posterior region.
  • - It was concluded that activating MAR enhances VRF diagnosis for all tested metal posts in the anterior region and specifically for nickel-chromium posts in the posterior region, suggesting its use in clinical imaging.
View Article and Find Full Text PDF

This study aimed to estimate the risks of adverse infant outcomes in the first year of life related to prenatal Zika virus (ZIKV) exposure. A prospective cohort of pregnant women with rash was recruited in Central-West Brazil in a post-epidemic period (January 2017 to April 2019). We evaluated participants' medical histories and performed ZIKV diagnostic testing using molecular (reverse transcription polymerase chain reaction [RT-PCR]) and serologic (immunoglobulin [Ig]M and plaque reduction neutralization tests [PRNT]) assays.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to correlate the translucency degree of varying resin composites with their radiopacity.

Methods And Materials: Twenty-four resin composites (conventional or bulk-fill) of various shades and opacities were selected from the following manufacturers: 3M ESPE (nanofilled), Ivoclar (nanohybrid), and FGM (microhybrid). Resin composite samples (n=5) were prepared (5-mm diameter × 1.

View Article and Find Full Text PDF

This paper presents an automated Non-Destructive Testing (NDT) system for the in-service inspection of orbital welds on tubular components operating at temperatures as high as 200 °C. The combination of two different NDT methods and respective inspection systems is here proposed to cover the detection of all potential defective weld conditions. The proposed NDT system combines ultrasounds and Eddy current techniques with dedicated approaches for dealing with high temperature conditions.

View Article and Find Full Text PDF

This work presents a new eddy current testing array probe and readout electronics that target the layer-wise quality control in powder bed fusion metal additive manufacturing. The proposed design approach brings important benefits to the sensors' number scalability, exploring alternative sensor elements and minimalist signal generation and demodulation. Small-sized, commercially available surface-mounted technology coils were evaluated as an alternative to usually employed magneto-resistive sensors, demonstrating low cost, design flexibility, and easy integration with the readout electronics.

View Article and Find Full Text PDF

Background: Genetic variability is the most important parameter in plant breeding based on selection. There is a need for morpho-agronomic and molecular characterization of Passiflora species, to exploit their genetic resources more efficiently. No study has yet been carried out to compare half-sib and full-sib families in relation to the magnitude of the genetic variability obtained in them, and then to elucidate the advantages or disadvantages of each one.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to evaluate whether the presence of the second mesiobuccal (MB2) canal is related to volumetric differences on the adjacent canals of maxillary molars.

Design: Forty-seven maxillary first and second molars with and without the MB2 canal were individually scanned using microcomputed tomography (micro-CT). The volume of each canal was measured by an evaluator with experience in micro-CT analysis.

View Article and Find Full Text PDF

Background: There is no established acquisition protocol based on scientific evidence for the acquisition of cone-beam computed tomography (CBCT) exams to evaluate the temporomandibular joint (TMJ).

Objectives: To evaluate the influence of acquisition protocols and jaw positioning on the diagnostic accuracy of TMJ condylar morphological alterations (CMA), dimension, position and excursion.

Methods: Thirty-six TMJs on 18 dry skulls were imaged using a CBCT unit (OP300 Maxio, Instrumentarium, Tuusula, Finland) at two exposure settings (4.

View Article and Find Full Text PDF

Objective: To evaluate the potential of maxillary molar dimensions as predictors of the presence of the second mesiobuccal (MB2) canal.

Methods: Micro-computed tomography scans were obtained from 47 maxillary molars, out of which 26 had the MB2 canal. The distance between root canals, extension of the canals, and thickness of surrounding dentin were obtained from axial images at the furcation level, 3 mm from the apex, and 5 mm from the apex.

View Article and Find Full Text PDF

The Zika virus (ZIKV) epidemic, which was followed by an unprecedented outbreak of congenital microcephaly, emerged in Brazil unevenly, with apparent pockets of susceptibility. The present study aimed to detect high-risk areas for ZIKV infection and microcephaly in Goiania, a large city of 1.5 million inhabitants in Central-West Brazil.

View Article and Find Full Text PDF

Objectives: This study investigated the internal morphology of mesiobuccal (MB) roots of maxillary molars with a second mesiobuccal (MB2) canal.

Materials And Methods: Forty-seven maxillary first or second molars from Brazilians were scanned using micro-computed tomography. The following measurements were obtained from the MB roots: root thickness, root width, and dentin thickness of the buccal aspect of the first mesiobuccal (MB1) canal, between the MB1 and MB2 canals, and the palatal aspect of the MB2 and MB1 canals at 3 mm from the root apex and in the furcation region.

View Article and Find Full Text PDF

This study aimed to assess the effect of the MAR tool on the expression of artefacts in different regions of a tooth restored with different types of metal posts. Alveolar sockets (anterior, and posterior region) of a mandible and an unirradicular tooth were used. Cone beam computed tomography scans of the tooth without a metal post, and with cobalt-chromium (Co-Cr), nickel-chromium (Ni-Cr), or silver-palladium (Ag-Pd) were individually obtained, with 2 MAR conditions: disabled, and enabled.

View Article and Find Full Text PDF

The need for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) next-generation vaccines has been highlighted by the rise of variants of concern (VoCs) and the long-term threat of emerging coronaviruses. Here, we design and characterize four categories of engineered nanoparticle immunogens that recapitulate the structural and antigenic properties of the prefusion SARS-CoV-2 spike (S), S1, and receptor-binding domain (RBD). These immunogens induce robust S binding, ACE2 inhibition, and authentic and pseudovirus neutralizing antibodies against SARS-CoV-2.

View Article and Find Full Text PDF

Automobile laser brazing remains a complex process whose results are affected by several process variables that may result in nonacceptable welds. A multisensory customized inspection system is proposed, with two distinct non-destructive techniques: the potential drop method and eddy current testing. New probes were designed, simulated, produced, and experimentally validated in automobile's laser-brazed weld beads with artificially introduced defects.

View Article and Find Full Text PDF

Dermoscopic images allow the detailed examination of subsurface characteristics of the skin, which led to creating several substantial databases of diverse skin lesions. However, the dermoscope is not an easily accessible tool in some regions. A less expensive alternative could be acquiring medium resolution clinical macroscopic images of skin lesions.

View Article and Find Full Text PDF

The aim of this study was to assess the diagnostic accuracy of digital periapical radiography for the detection of the second mesiobuccal (MB2) canal when the adjacent canals are unfilled or filled with gutta percha. Forty human maxillary first molars were selected, 20 of which had an MB2 canal. The presence or absence of the MB2 canal was confirmed using microcomputed tomography.

View Article and Find Full Text PDF

Objective: To compare the expression of the volumetric alteration (VA) artifact between cylindrical and convex triangular fields of view (FOVs) using high-density materials in different positions in two cone-beam computed tomography (CBCT) devices.

Materials And Methods: Cylinders of five high-density materials (amalgam, chromium-cobalt, gutta-percha, titanium, and zirconium) with known physical volume were individually submitted to CBCT acquisition in four positions inside a polymethylmethacrylate phantom using two different FOV shapes (convex triangular and cylindrical) on the Veraviewepocs® R100 (R100) and Veraview® X800 (X800) devices. Two oral radiologists obtained the tomographic volumes by segmenting each cylinder.

View Article and Find Full Text PDF
Article Synopsis
  • Cell-free DNA (cfDNA) from pleural effusion supernatant (PES) is being studied for its potential in molecular tumor profiling for metastatic non-small cell lung carcinoma (NSCLC).
  • The study involved collecting pleural effusion specimens, extracting DNA, and comparing results with DNA from formalin-fixed paraffin-embedded (FFPE) samples using targeted next-generation sequencing (NGS).
  • Challenges were observed in the extraction and sequencing processes, yet the findings suggest that PES is still a valuable source of cfDNA for genetic analysis despite certain limitations in mutation detection and sample variation.
View Article and Find Full Text PDF