Appl Occup Environ Hyg
June 2003
Video exposure assessments were conducted in a comparative anatomy laboratory using formaldehyde-preserved sharks and cats. Work in the facility using time-integrated samplers indicated personal and area concentrations generally below the current OSHA permissible exposure limit. However, complaints about room air quality were frequent and routine.
View Article and Find Full Text PDFThis case study demonstrates how methylene chloride exposures during furniture stripping can be reduced to below the Occupational Safety and Health Administration (OSHA) permissible exposure limit (PEL) of 25 ppm (as an 8-hour time-weighted average). Five surveys were conducted at one facility; the first four resulted in employee exposure geometric means from 39 to 332 ppm. For the fifth survey local exhaust ventilation was used at the stripping tank and the rinsing area, which together exhausted 138 m3/min (4860 ft3/min).
View Article and Find Full Text PDFReal-time monitoring was used to evaluate the ability of engineering control devices retrofitted on two existing dry-cleaning machines to reduce worker exposures to perchloroethylene. In one dry-cleaning shop, a refrigerated condenser was installed on a machine that had a water-cooled condenser to reduce the air temperature, improve vapor recovery, and lower exposures. In a second shop, a carbon adsorber was retrofitted on a machine to adsorb residual perchloroethylene not collected by the existing refrigerated condenser to improve vapor recovery and reduce exposures.
View Article and Find Full Text PDF