Unlabelled: The goal of this paper was to evaluate the in vivo kinetics of the novel tau-specific PET radioligand F-AV-1451 in cognitively healthy control (HC) and Alzheimer disease (AD) subjects, using reference region analyses.
Methods: F-AV-1451 PET imaging was performed on 43 subjects (5 young HCs, 23 older HCs, and 15 AD subjects). Data were collected from 0 to 150 min after injection, with a break from 100 to 120 min.
The goal of this project is to develop radionuclide molecular imaging technologies using a clinical pinhole SPECT/CT scanner to quantify changes in cardiac metabolism using the spontaneously hypertensive rat (SHR) as a model of hypertensive-related pathophysiology. This paper quantitatively compares fatty acid metabolism in hearts of SHR and Wistar-Kyoto normal rats as a function of age and thereby tracks physiological changes associated with the onset and progression of heart failure in the SHR model. The fatty acid analog, (123)I-labeled BMIPP, was used in longitudinal metabolic pinhole SPECT imaging studies performed every seven months for 21 months.
View Article and Find Full Text PDFIn this paper, we investigate the performance of time-of-flight (TOF) positron emission tomography (PET) in improving lesion detectability. We present a theoretical approach to compare lesion detectability of TOF versus non-TOF systems and perform computer simulations to validate the theoretical prediction. A single-ring TOF PET tomograph is simulated using SimSET software, and images are reconstructed in 2D from list-mode data using a maximum a posteriori method.
View Article and Find Full Text PDFProc IEEE Int Symp Biomed Imaging
August 2009
In this paper, we investigate the performance of time-of-flight (TOF) PET in improving lesion detectability. We present a theoretical approach to compare lesion detectability of TOF versus non-TOF systems. Computer simulations are performed to validate the theoretical predictions.
View Article and Find Full Text PDFThe objective of this research was to assess applicability of a technique known as hyperelastic warping for the measurement of local strains in the left ventricle (LV) directly from microPET image data sets. The technique uses differences in image intensities between template (reference) and target (loaded) image data sets to generate a body force that deforms a finite element (FE) representation of the template so that it registers with the target images. For validation, the template image was defined as the end-systolic microPET image data set from a Wistar Kyoto (WKY) rat.
View Article and Find Full Text PDFWe present a retrospective on the LBNL Positron Emission Mammography (PEM) project, looking back on our design and experiences. The LBNL PEM camera utilizes detector modules that are capable of measuring depth of interaction (DOI) and places them into 4 detector banks in a rectangular geometry. In order to build this camera, we had to develop the DOI detector module, LSO etching, Lumirror-epoxy reflector for the LSO array (to achieve optimal DOI), photodiode array, custom IC, rigid-flex readout board, packaging, DOI calibration and reconstruction algorithms for the rectangular camera geometry.
View Article and Find Full Text PDFIEEE Trans Med Imaging
September 2006
Medical images in nuclear medicine are commonly represented in three dimensions as a stack of two-dimensional images that are reconstructed from tomographic projections. Although natural and straightforward, this may not be an optimal visual representation for performing various diagnostic tasks. A method for three-dimensional (3-D) tomographic reconstruction is developed using a point cloud image representation.
View Article and Find Full Text PDFDetecting cancerous lesions is one major application in emission tomography. In this paper, we study penalized maximum-likelihood image reconstruction for this important clinical task. Compared to analytical reconstruction methods, statistical approaches can improve the image quality by accurately modelling the photon detection process and measurement noise in imaging systems.
View Article and Find Full Text PDFUnlabelled: Currently, 2 types of phantoms (physical and computer generated) are used for testing and comparing tomographic reconstruction methods. Data from physical phantoms include all physical effects associated with the detection of radiation. However, with physical phantoms it is difficult to control the number of detected counts, simulate the dynamics of uptake and washout, or create multiple noise realizations of an acquisition.
View Article and Find Full Text PDFIEEE Trans Med Imaging
May 2006
Region of interest (ROI) quantification is an important task in emission tomography (e.g., positron emission tomography and single photon emission computed tomography).
View Article and Find Full Text PDFStatistically based iterative image reconstruction methods have been developed for emission tomography. One important component in iterative image reconstruction is the system matrix, which defines the mapping from the image space to the data space. Several groups have demonstrated that an accurate system matrix can improve image quality in both single photon emission computed tomography (SPECT) and positron emission tomography (PET).
View Article and Find Full Text PDFUnlabelled: The goals of this investigation were to assess the accuracy of (18)F-fluorodihydrorotenone ((18)F-FDHR) as a new deposited myocardial flow tracer and to compare the results to those for (201)Tl.
Methods: The kinetics of these flow tracers in 22 isolated, erythrocyte- and albumin-perfused rabbit hearts were evaluated over a flow range encountered in patients. The 2 flow tracers plus a vascular reference tracer ((131)I-albumin) were introduced as a bolus through a port just above the aortic cannula.
IEEE Trans Med Imaging
September 2004
List mode image reconstruction is attracting renewed attention. It eliminates the storage of empty sinogram bins. However, a single back projection of all LORs is still necessary for the pre-calculation of a sensitivity image.
View Article and Find Full Text PDFAm J Physiol Heart Circ Physiol
February 2003
The purpose of this study was to evaluate flow heterogeneity and impaired reflow during reperfusion after 60-min global no-flow ischemia in the isolated rabbit heart. Radiolabeled microspheres were used to measure relative flow in small left ventricular (LV) segments in five ischemia + reperfused hearts and in five nonischemic controls. Relative flow heterogeneity was expressed as relative dispersion (RD) and computed as standard deviation/mean.
View Article and Find Full Text PDFIn this paper we present a scatter correction method for a regularized list mode maximum likelihood reconstruction algorithm for the positron emission mammograph (PEM) that is being developed at our laboratory. The scatter events inside the object are modelled as additive Poisson random variables in the forward model of the reconstruction algorithm. The mean scatter sinogram is estimated using a Monte Carlo simulation program.
View Article and Find Full Text PDFIEEE Trans Med Imaging
March 2002
Factor analysis is a powerful tool used for the analysis of dynamic studies. One of the major drawbacks of factor analysis of dynamic structures (FADS) is that the solution is not mathematically unique when only nonnegativity constraints are used to determine factors and factor coefficients. In this paper, a method to correct for ambiguous FADS solutions has been developed.
View Article and Find Full Text PDFBackground: One of the major problems associated with technetium 99m teboroxime cardiac imaging is the high concentration of activity in the liver. In some cases it is impossible to diagnose defects on the inferior wall because of the finite resolution and scatter that cause images of the inferior wall and the liver to overlap.
Methods And Results: The least-squares factor analysis of dynamic structures method, with correction for non-unique solutions, was used to remove the liver activity from the image.
A four-dimensional deformable motion algorithm is described for use in the motion compensation of gated cardiac positron emission tomography. The algorithm makes use of temporal continuity and a non-uniform elastic material model to provide improved estimates of heart motion between time frames. Temporal continuity is utilized in two ways.
View Article and Find Full Text PDF