Objectives: This study examines the early and midterm safety, efficacy, and durability of mitral valve repair for primary mitral regurgitation (MR) using the ChordArt device (CoreMedic) for chordal replacement.

Methods: Five patients with symptomatic severe primary degenerative MR due to isolated central posterior leaflet prolapse/flail were treated with the ChordArt device in a transseptal surgical approach and followed prospectively with periodical clinical and echocardiographic assessments for 2 years.

Results: Reduction of MR immediately after the implantation of artificial chords was achieved in all patients showing no or trace MR (<1+/4+).

View Article and Find Full Text PDF

Purpose: The pre-clinical testing of cardiovascular implants gains increasing attention due to the complexity of novel implants and new medical device regulations. It often relies on large animal experiments that are afflicted with ethical and methodical challenges. Thus, a method for simulating physiological heart motions is desired but lacking so far.

View Article and Find Full Text PDF

Objective: Wave intensity analysis is a method that allows separating pulse waves into components generated proximally and in the periphery of arterial trees, as well as characterising them as accelerating or decelerating. The early diastolic suction wave (eaDSW) is one of the most prominent wave events in the coronaries. The aim of this study was to determine whether (1) microvascular dilatation directly influences its energy, (2) stenosis severity can be assessed proximal to stenoses, (3) distal pulse wave entrapment exists in the presence of stenoses and (4) coronary collaterals influence wave entrapment.

View Article and Find Full Text PDF

Purpose: A novel chordal system enables automated implantation of artificial mitral chords to treat mitral regurgitation (MR). This article summarizes the first-in-man initial clinical results.

Description: The CHAGALL (CHordArt system study for the treatment of mitral ReGurgitAtion due to leaflet proLapse or fLail) trial is a single arm, multicenter, prospective study to test the feasibility of this system for mitral repair.

View Article and Find Full Text PDF

The field of mitral valve disease diagnosis and management is rapidly evolving. New understanding of pathophysiology and improvements in the adoption of sophisticated multimodality imaging modalities have led to early diagnosis and to more complex treatment. The most common cause of mitral regurgitation (MR) in the western world is in the primary alteration of the valve, which leads to degenerative leaflet prolapse due to chordal elongation or rupture and annular dilatation.

View Article and Find Full Text PDF

Objective: cardiac pacemakers require regular medical follow-ups to ensure proper functioning. However, device replacements due to battery depletion are common and account for ∼25% of all implantation procedures. Furthermore, conventional pacemakers require pacemaker leads which are prone to fractures, dislocations or isolation defects.

View Article and Find Full Text PDF

Background: Borderline personality disorder (BPD) and major depressive disorder (MDD) pose a significant burden to the German health care system in terms of direct and indirect costs. The aim of this study was to determine the incremental costs that arise due to the treatment of patients with BPD, in relation to MDD patients adjusted for gender and age.

Methods: Insured persons who suffered from BPD (F60.

View Article and Find Full Text PDF

Energy harvesting devices are widely discussed as an alternative power source for todays active implantable medical devices. Repeated battery replacement procedures can be avoided by extending the implants life span, which is the goal of energy harvesting concepts. This reduces the risk of complications for the patient and may even reduce device size.

View Article and Find Full Text PDF

Objective: To evaluate the effect of acute cardiac sympathectomy by thoracic epidural anesthesia on myocardial blood flow and microvascular function.

Design: A prospective observational study.

Setting: The study was conducted in a tertiary teaching hospital.

View Article and Find Full Text PDF

History: A 36-year-old man with a history of PR3-ANCA positive granulomatosis with polyangiitis presented with chest pain at the emergency department. Due to his underlying disease, he was treated with Rituximab in regular intervals. The last Rituximab infusion was admitted one day before presentation.

View Article and Find Full Text PDF

Purpose: Paroxysmal atrial fibrillation (PAF) often remains undiagnosed. Long-term surface ECG is used for screening, but has limitations. Esophageal ECG (eECG) allows recording high quality atrial signals, which were used to identify markers for PAF.

View Article and Find Full Text PDF

Cardiac pacemakers are routinely used for the treatment of bradyarrhythmias. Contemporary pacemakers are reliable and allow for a patient specific programming. However, pacemaker replacements due to battery depletion are common (~25 % of all implantation procedures) and bear the risk of complications.

View Article and Find Full Text PDF

Long-term electrocardiogram (ECG) signals might suffer from relevant baseline disturbances during physical activity. Motion artifacts in particular are more pronounced with dry surface or esophageal electrodes which are dedicated to prolonged ECG recording. In this paper we present a method called baseline wander tracking (BWT) that tracks and rejects strong baseline disturbances and avoids concurrent saturation of the analog front-end.

View Article and Find Full Text PDF

Background: Contemporary pacemakers (PMs) are powered by primary batteries with a limited energy-storing capacity. PM replacements because of battery depletion are common and unpleasant and bear the risk of complications. Batteryless PMs that harvest energy inside the body may overcome these limitations.

View Article and Find Full Text PDF

Long-term electrocardiogram (ECG) often suffers from relevant noise. Baseline wander in particular is pronounced in ECG recordings using dry or esophageal electrodes, which are dedicated for prolonged registration. While analog high-pass filters introduce phase distortions, reliable offline filtering of the baseline wander implies a computational burden that has to be put in relation to the increase in signal-to-baseline ratio (SBR).

View Article and Find Full Text PDF

Aims: Today's cardiac pacemakers are powered by batteries with limited energy capacity. As the battery's lifetime ends, the pacemaker needs to be replaced. This surgical re-intervention is costly and bears the risk of complications.

View Article and Find Full Text PDF

Replacement intervals of implantable medical devices are commonly dictated by battery life. Therefore, intracorporeal energy harvesting has the potential to reduce the number of surgical interventions by extending the life cycle of active devices. Given the accumulated experience with intravascular devices such as stents, heart valves, and cardiac assist devices, the idea to harvest a small fraction of the hydraulic energy available in the cardiovascular circulation is revisited.

View Article and Find Full Text PDF

Background: Atrial fibrillation (AF) is common and may have severe consequences. Continuous long-term electrocardiogram (ECG) is widely used for AF screening. Recently, commercial ECG analysis software was launched, which automatically detects AF in long-term ECGs.

View Article and Find Full Text PDF

Background: Ischemia monitoring cannot always be performed by 12-lead ECG. Hence, the individual performance of the ECG leads is crucial. No experimental data on the ECG's specificity for transient ischemia exist.

View Article and Find Full Text PDF

Aims: Angiographic ectasias and aneurysms in stented segments have been associated with late stent thrombosis. Using optical coherence tomography (OCT), some stented segments show coronary evaginations reminiscent of ectasias. The purpose of this study was to explore, using computational fluid-dynamic (CFD) simulations, whether OCT-detected coronary evaginations can induce local changes in blood flow.

View Article and Find Full Text PDF

Objective: To evaluate the effect of heart rate reduction by ivabradine on coronary collateral function in patients with chronic stable coronary artery disease (CAD).

Methods: This was a prospective randomised placebo-controlled monocentre trial in a university hospital setting. 46 patients with chronic stable CAD received placebo (n=23) or ivabradine (n=23) for the duration of 6 months.

View Article and Find Full Text PDF

Human energy harvesting is envisioned as a remedy to the weight, the size, and the poor energy density of primary batteries in medical implants. The first implant to have necessarily raised the idea of a biological power supply was the pacemaker in the early 1960s. So far, review articles on human energy harvesting have been rather unspecific and no tribute has been given to the early role of the pacemaker and the cardiovascular system in triggering research in the field.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionglh9klfl9vbea87jufpuvhg8p8hqnh23): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once