Publications by authors named "Rolf Pohmann"

The increasing signal-to-noise ratio (SNR) is the main reason to use ultrahigh field MRI. Here, we investigate the dependence of the SNR on the magnetic field strength, especially for small animal applications, where small surface coils are used and coil noise cannot be ignored. Measurements were performed at five field strengths from 3 to 14.

View Article and Find Full Text PDF

High-field preclinical functional MRI (fMRI) is enabled the high spatial resolution mapping of vessel-specific hemodynamic responses, that is single-vessel fMRI. In contrast to investigating the neuronal sources of the fMRI signal, single-vessel fMRI focuses on elucidating its vascular origin, which can be readily implemented to identify vascular changes relevant to vascular dementia or cognitive impairment. However, the limited spatial and temporal resolution of fMRI is hindered hemodynamic mapping of intracortical microvessels.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the effectiveness of vessel-encoded arterial spin labeling (VE-ASL) in visualizing blood flow from individual arteries in the brain, compared to the traditional method of digital subtraction angiography (DSA).
  • A review of data from 20 VE-ASL and DSA sets involving 17 patients with Moyamoya angiopathy showed a high level of agreement between the two imaging techniques.
  • The findings suggest that VE-ASL is a reliable non-invasive alternative for assessing cerebral blood flow contributions, making it particularly useful both before and after revascularization surgery.
View Article and Find Full Text PDF

Laminar-specific functional magnetic resonance imaging (fMRI) has been widely used to study circuit-specific neuronal activity by mapping spatiotemporal fMRI response patterns across cortical layers. Hemodynamic responses reflect indirect neuronal activity given limit of spatial and temporal resolution. Previous gradient-echo based line-scanning fMRI (GELINE) method was proposed with high temporal (50 ms) and spatial (50 µm) resolution to better characterize the fMRI onset time across cortical layers by employing 2 saturation RF pulses.

View Article and Find Full Text PDF

Background Arterial spin labeling (ASL) MRI can be used to assess organ perfusion but has yet to be implemented for perfusion evaluation of the lung. Purpose To evaluate pseudo-continuous ASL (PCASL) MRI for the detection of acute pulmonary embolism (PE) and its potential as an alternative to CT pulmonary angiography (CTPA). Materials and Methods Between November 2020 and November 2021, 97 patients (median age, 61 years; 48 women) with suspected PE were enrolled in this prospective study.

View Article and Find Full Text PDF

Intrinsic optical imaging (IOI) is a well established technique to quantify activation-related hemodynamical changes at the surface of the brain, which can be used to investigate the underlying processes of BOLD signal formation. To directly and quantitatively relate IOI and fMRI, simultaneous measurements with the two modalities are necessary. Here, a novel technical solution for a completely in-bore setup is presented, which uses only magnetic field proof components and thus allows concurrent recordings with a quality similar to that obtained in separate experiments.

View Article and Find Full Text PDF

Current approaches to high-field functional MRI (fMRI) provide 2 means to map hemodynamics at the level of single vessels in the brain. One is through changes in deoxyhemoglobin in venules, i.e.

View Article and Find Full Text PDF

Purpose: To investigate the intravascular contribution to the overall balanced SSFP (bSSFP) BOLD effect in human blood at high to ultrahigh field strengths (3 T, 9.4 T, and 14.1 T).

View Article and Find Full Text PDF

Purpose: Oxygen-17 ( O) MRS imaging, successfully used in the brain, is extended by imaging the oxygen metabolic rate in the resting skeletal muscle and used to determine the total whole-body oxygen metabolic rate in the rat.

Methods: During and after inhalations of O gas, dynamic O MRSI was performed in rats (n = 8) ventilated with N O or N at 16.4 T.

View Article and Find Full Text PDF

Background: Quantitative assessment of pulmonary blood flow and visualization of its temporal and spatial distribution without contrast media is of clinical significance.

Purpose: To assess the potential of electrocardiogram (ECG)-triggered pseudocontinuous arterial spin labeling (PCASL) imaging with balanced steady-state free-precession (bSSFP) readout to measure lung perfusion under free-breathing (FB) conditions and to study temporal and spatial characteristics of pulmonary blood flow.

Study Type: Prospective, observational.

View Article and Find Full Text PDF

We present a method for assessing the extracellular calcium concentration using F chemical shift imaging. Specifically, a custom made calcium-responsive and lanthanide-based F MRI probe that undergoes a strong and highly specific modulation of its signal upon coordination with calcium ions was developed and its performance is presented.

View Article and Find Full Text PDF

Alzheimer's disease (AD) is the most common cause of dementia worldwide. So far, diagnosis of AD is only unequivocally defined through postmortem histology. Amyloid plaques are a classical hallmark of AD and amyloid load is currently quantified by Positron Emission tomography (PET) in vivo.

View Article and Find Full Text PDF

Functional imaging with sub-millimeter spatial resolution is a basic requirement for assessing functional MRI (fMRI) responses across different cortical depths and is used extensively in the emerging field of laminar fMRI. Such studies seek to investigate the detailed functional organization of the brain and may develop to a new powerful tool for human neuroscience. However, several studies have shown that measurement of laminar fMRI responses can be biased by the image acquisition and data processing strategies.

View Article and Find Full Text PDF

Magnetic resonance imaging and spectroscopy are versatile methods for probing brain physiology, but their intrinsically low sensitivity limits the achievable spatial and temporal resolution. Here, we introduce a monolithically integrated NMR-on-a-chip needle that combines an ultra-sensitive 300 µm NMR coil with a complete NMR transceiver, enabling in vivo measurements of blood oxygenation and flow in nanoliter volumes at a sampling rate of 200 Hz.

View Article and Find Full Text PDF

Aims: To determine individual glucose hydroxyl exchange rates at physiological conditions and use this information for numerical optimization of glucoCEST/CESL preparation. To give guidelines for in vivo glucoCEST/CESL measurement parameters at clinical and ultra-high field strengths.

Methods: Five glucose solution samples at different pH values were measured at 14.

View Article and Find Full Text PDF

Ultralow-field (ULF) nuclear magnetic resonance spectroscopy (MRS) and magnetic resonance imaging (MRI) are promising spectroscopy and imaging methods allowing for, e.g., the simultaneous detection of multiple nuclei or imaging in the vicinity of metals.

View Article and Find Full Text PDF

Purpose: To investigate the capabilities of a modern pseudo-continuous arterial spin labeling (PCASL) technique for non-invasive assessment of the temporal and spatial distribution of the liver perfusion in healthy volunteers on a clinical MR system at 3T.

Materials And Methods: A 2D-PCASL multi-slice echo planar imaging sequence was adapted to the specific conditions in liver: a) labeling by PCASL was optimized to the flow characteristics in the portal vein, b) background suppression was applied for reduction of motion related artifacts, c) post labeling delays (PLDs) were varied over a large range (0.7-3.

View Article and Find Full Text PDF

We explored anatomical details of the superior colliculus (SC) by in vivo magnetic resonance imaging (MRI) at 9.4T. The high signal-to-noise ratio allowed the acquisition of high resolution, multi-modal images with voxel sizes ranging between 176 × 132 × 600 μm and (800)μm.

View Article and Find Full Text PDF

Functional MRI has been used to map brain activity and functional connectivity based on the strength and temporal coherence of neurovascular-coupled hemodynamic signals. Here, single-vessel fMRI reveals vessel-specific correlation patterns in both rodents and humans. In anesthetized rats, fluctuations in the vessel-specific fMRI signal are correlated with the intracellular calcium signal measured in neighboring neurons.

View Article and Find Full Text PDF

Context: Insulin action in the human brain influences eating behavior, cognition, and whole-body metabolism. Studies investigating brain insulin rely on intranasal application.

Objective: To investigate effects of three doses of insulin and placebo as nasal sprays on the central and autonomous nervous system and analyze absorption of insulin into the bloodstream.

View Article and Find Full Text PDF

Purpose: Respiratory motion prediction using an artificial neural network (ANN) was integrated with pseudocontinuous arterial spin labeling (pCASL) MRI to allow free-breathing perfusion measurements in the kidney. In this study, we evaluated the performance of the ANN to accurately predict the location of the kidneys during image acquisition.

Methods: A pencil-beam navigator was integrated with a pCASL sequence to measure lung/diaphragm motion during ANN training and the pCASL transit delay.

View Article and Find Full Text PDF

Purpose: The purpose of this work was to develop a fast and efficient MRSI-FID acquisition scheme and test its performance in vivo. The aim was to find a trade-off between the minimal total acquisition time and signal-to-noise ratio of the acquired spectra.

Methods: Measurements were performed on a 9.

View Article and Find Full Text PDF

The preparation of a paramagnetic chelator that serves as a platform for multicontrast MRI, and can be utilized either as a T1-weighted, paraCEST or (19)F MRI contrast agent is reported. Its europium(iii) complex exhibits an extremely slow water exchange rate which is optimal for the use in CEST MRI. The potential of this platform was demonstrated through a series of MRI studies on tube phantoms and animals.

View Article and Find Full Text PDF