Publications by authors named "Rohwedder J"

We report a terahertz time-domain study of dewetting kinetics on two time scales: femtoseconds and in real time (on the order of minutes). We recorded full electric field terahertz time domain signals with femtosecond time resolution during dewetting of water in cellulose. The femtosecond time-domain signals were analyzed with respect to the amplitude and signal emission times and how these two quantities changed over the course of dewetting kinetics.

View Article and Find Full Text PDF

A comprehensive data set of ecstasy samples containing MDMA (N-methyl-3,4-methylenedioxyamphetamine) and MDA (3,4-methylenedioxyamphetamine) seized by the Brazilian Federal Police was characterized using spectral data obtained by a compact, low-cost, near-infrared Fourier-transform based spectrophotometer. Qualitative and quantitative characterization was accomplished using soft independent modeling of class analogy (SIMCA), linear discriminant analysis (LDA) classification, discriminating partial least square (PLS-DA), and regression models based on partial least square (PLS). By applying chemometric analysis, a protocol can be proposed for the in-field screening of seized ecstasy samples.

View Article and Find Full Text PDF

Calcium silicate-based materials are used to block the communication between the root canal and the periodontal ligament space. This brings the materials into contact with tissues and the potential for local and systemic elemental release and movement. The aim of the study was to evaluate the elemental release of bismuth from ProRoot MTA in contact with connective tissues after 30 and 180 days as well as any accumulation in peripheral organs using an animal model.

View Article and Find Full Text PDF

This paper describes a new method to obtain NIR spectra of liquid and gas samples by diffuse reflectance, which is especially suitable for handheld spectrophotometers, since most of these instruments are designed to acquire spectrum using this geometry. The core of the method is a diffuse reflectance cell, which consists of a vial containing a mixture of the liquid or gas sample (rare medium) and a powder (dense medium). Using this strategy, no adaptation is required to measure spectra with most portable NIR spectrometers.

View Article and Find Full Text PDF

While theophylline has been extensively studied with multiple polymorphs discovered, there is still currently no conclusive structure for the metastable theophylline form III. In this present work, by combining more widely used techniques such as X-ray diffraction and thermogravimetric analysis with more emerging techniques like low-frequency Raman and terahertz time-domain spectroscopy, to analyze the structure and dynamics of a crystalline system, it was possible to provide further evidence that the form III structure has a theophylline monohydrate structure with the water molecules removed. Solid-state density functional theory simulations were paramount in proving that this proposed structure is correct and explain how vibrational modes within the crystal structures feature and govern polymorphic transitions and the metastable form III.

View Article and Find Full Text PDF

The objective of the current in-vitro study was to evaluate the biocompatibility of a new type of CAD/CAM scaffold for bone tissue engineering by using human cells. Porous lightweight titanium scaffolds and Bio-Oss® scaffolds as well as their eluates were used for incubation with human osteoblasts, fibroblasts and osteosarcoma cells. The cell viability was assessed by using fluorescein diazo-acetate propidium iodide staining.

View Article and Find Full Text PDF

This work describes an optical configuration for a Raman spectrophotometer, which permits variation of the laser spot size from 3 to 3000 μm, maintaining a high Raman photons throughput and allowing acquisitions with a short integration time. In addition, the instrument can acquire spectra from the low to middle frequency vibrational range (10 to 2000 cm), on the Stokes and anti-Stokes sides. One of the features of this new optical configuration is the non-use of beam splitters to redirect the scattered light to the detector, which would sacrifice the laser power.

View Article and Find Full Text PDF

This work reports on the use of micro- and macro-Raman measurements for quantification of mebendazole (MBZ) polymorphs A, B, and C in mixtures. Three Raman spectrophotometers were studied with a laser spot size of 3, 80 and 100 μm and spectral resolutions of 3.9, 9 and 4 cm, respectively.

View Article and Find Full Text PDF

Near infrared emission spectroscopy (NIRES) has been investigated to yield a new analytical method for determination of CaO, SiO, AlO, FeO, MgO, and SO in Portland cement samples. The analyses were accomplished by correlation of the second derivative NIRES spectra with reference elemental analyses made by X-ray Fluorescence (XRF), using Partial Least Square (PLS) regression models. Four different types of cements (type II, III, IV and V) were included in the models.

View Article and Find Full Text PDF

This work presents an analytical method based on terahertz-time domain spectroscopy (THz-TDS) and partial least squares (PLS) regression models to quantify mebendazole (MBZ) polymorphs (forms A, B and C) in pharmaceutical raw material. Mebendazole polymorphs A, B and C were quantified with RMSEP values of 1.5% w/w, 1.

View Article and Find Full Text PDF

A novel heart-shaped substrate-integrated hollow waveguide (hiHWG) was integrated with a near-infrared micro-spectrometer (μNIR) for sensing natural gases, resulting in an ultra-compact near-infrared gas sensing system - iHEART. The iHEART system was evaluated using two different μNIR spectrometers, and the performance was compared with a laboratory NIR spectrometer for gas analysis based on an acousto-optic tunable filter (AOTF). The spectral data were pre-processed using the 1(st) derivative Savitzky-Golay algorithm, and then used for establishing multivariate regression models based on partial least squares (PLS).

View Article and Find Full Text PDF

The use of electric fields as additional driving forces in sample preparation techniques is an innovative approach that is environmentally friendly, straightforward, and able to overcome several limitations of conventional sample preparation procedures. In this work, the advantages of electric field-assisted solid phase extraction (E-SPE) using syringe-type cartridges were demonstrated for the extraction of four fluoroquinolones (FQs) in their anionic forms. The FQs were extracted from eggs and subsequently determined by UHPLC-MS/MS.

View Article and Find Full Text PDF

A method using the ring-oven technique for pre-concentration in filter paper discs and near infrared hyperspectral imaging is proposed to identify four detergent and dispersant additives, and to determine their concentration in gasoline. Different approaches were used to select the best image data processing in order to gather the relevant spectral information. This was attained by selecting the pixels of the region of interest (ROI), using a pre-calculated threshold value of the PCA scores arranged as histograms, to select the spectra set; summing up the selected spectra to achieve representativeness; and compensating for the superimposed filter paper spectral information, also supported by scores histograms for each individual sample.

View Article and Find Full Text PDF

A miniaturised gas analyser is described and evaluated based on the use of a substrate-integrated hollow waveguide (iHWG) coupled to a microsized near-infrared spectrophotometer comprising a linear variable filter and an array of InGaAs detectors. This gas sensing system was applied to analyse surrogate samples of natural fuel gas containing methane, ethane, propane and butane, quantified by using multivariate regression models based on partial least square (PLS) algorithms and Savitzky-Golay 1(st) derivative data preprocessing. The external validation of the obtained models reveals root mean square errors of prediction of 0.

View Article and Find Full Text PDF

A semiautomated solid-phase extraction manifold for multiple extractions is presented. The manifold utilizes commercial solid-phase syringe cartridges and automatically introduces and elutes all the solvents during the extraction, reducing the typical workload and stress of the analyst. The manifold consists of a peristaltic pump with solenoid valves in a flow circuit that contains transmissive photomicrosensors.

View Article and Find Full Text PDF

A new polarimetric instrument and measurement method is described based on the use of diode lasers as radiation source (532, 650 and 1064nm) and birefringent prisms, such as Glan-Laser and Wollaston, as analyzers. The laser radiation is passed through a dichroic polarizer film for further orientation of its polarization plane at 45° in relation to the polarization plane of the analyzer. The polarized beam, oriented in that way, passes the sample cell, impinges the prism surface, and the intensities of the two emerged beams are detected by two twin silicon detectors.

View Article and Find Full Text PDF

This work describes the development of flow analysis microsystems with integrated fluorimetric detection cells. Channels (width of 300-540 microm and depth of 200-590 microm) were manufactured by deep-UV lithography in urethane-acrylate (UA) resin. Plastic optical fibers (diameter of 250 microm) were coupled to a 2.

View Article and Find Full Text PDF

This paper presents two methodologies for monitoring the service condition of diesel-engine lubricating oils on the basis of infrared spectra. In the first approach, oils samples are discriminated into three groups, each one associated to a given wear stage. An algorithm is proposed to select spectral variables with good discriminant power and small collinearity for the purpose of discriminant analysis classification.

View Article and Find Full Text PDF

An automated system for liquid-liquid extraction flow analysis (LLE-FA) for the determination of Sb(V) in antileishmanial drugs is presented. The method is based on extraction in a 5mL glass extraction chamber of an ion pair formed between hexachloroantimoniate anion and rhodamine B cation into toluene. The detection system consists of a green light emitting diode (LED) and a photodiode.

View Article and Find Full Text PDF

A monosegmented flow system was employed for the determination of low contents of phosphate in natural water. In this approach, sample and reagents are simultaneously injected to a PTFE reaction coil where the homogenization of the mixture occurs while the monosegment is pumped forwards the photometric detector. The proposed system was evaluated by determining phosphate ion, based on the reaction of association between molybdophosphate and malachite green.

View Article and Find Full Text PDF

A glucose biosensor with enzyme immobilised by sol-gel technology was constructed and evaluated. The glucose biosensor reported is based on encapsulated GOX within a sol-gel glass, prepared with 3-aminopropyltriethoxy silane, 2-(3,4-epoxycyclohexyl)-ethyltrimetoxy silane and HCl. A flow system incorporating the amperometric biosensor constructed was developed for the determination of glucose in the 1x10(-4)-5x10(-3) moll(-1) range with a precision of 1.

View Article and Find Full Text PDF

In liquid-liquid extraction performed by monosegmented flow analysis (MSFA), the aqueous sample is introduced between two air bubbles and flows, under restricted dispersion, through a glass extraction tube where the analyte is retained, usually at pH higher than 8. The retained analyte is removed to a small volume of an organic phase containing a ligand which is introduced after the second air bubble. In this work, the effect of the organic phase composition on the extraction of Cu(II), Zn(II) and Cd(II) in MSFA systems was investigated by changing the ethanol content (0.

View Article and Find Full Text PDF

In this work a stainless steel electrode was prepared, characterised and used as indicator electrode in a potentiometric flow cell. Due to its versatility, it was possible to study different electrode geometries and flow cell arrangements. After optimising the system, mixtures of succinic and oxalic acids were determined by titration.

View Article and Find Full Text PDF

A versatile potentiometer that works with electrode arrays in flow injection and/or monosegmented flow systems is described. The potentiometer is controlled by a microcomputer that allows individual, sequential multiplexed or random accesses to eight electrodes while employing only one reference electrode. The instrument was demonstrated by monitoring an array of seven flow-through ion-selective electrodes for Ag+ and for three electrodes for Cl(-), Ca2+ and K+.

View Article and Find Full Text PDF