Background: The use of an antibacterial envelope is cost-effective for patients at high risk of developing cardiac implantable electronic device (CIED) infection. The identification of these high-risk patients may be facilitated using a clinical risk score. The aim of the current study is to evaluate the PADIT score for identifying high-risk patients in patients undergoing a CIED procedure in a tertiary academic center.
View Article and Find Full Text PDFBackground: Catheter ablation (CA) remains challenging due to suboptimal success rates in persistent atrial fibrillation (AF). Existing mapping technologies cannot reliably distinguish sources in this patient population. Recently, the novel electrographic flow (EGF) mapping system was developed using a modified Horn-Schunk optical flow algorithm to detect and quantify patterns of electrical wavefront propagation in the atria.
View Article and Find Full Text PDFBackground: Short runs of atrial tachycardias (ATs) and infrequent premature atrial contractions (PACs) are difficult to map and ablate using sequential electrophysiology mapping techniques. The AcQMap mapping system allows for highly accurate mapping of a single atrial activation.
Objectives: We aimed to test the value of a novel dipole charge density-based high-resolution mapping technique (AcQMap) in the treatment of brief episodes of ATs and PACs.
Initial experience suggests that the POLARx cryoballoon system (Boston Scientific) has a similar procedural efficacy and safety as Arctic Front Advance Pro (AFA-Pro, Medtronic). We performed an updated systematic review and meta-analysis comparing POLARx and AFA-Pro. Embase, MEDLINE, Web of Science, Cochrane, and Google Scholar databases were searched until 12/01/2022 for studies comparing POLARx versus AFA-Pro in patients undergoing pulmonary vein (PV) isolation for AF.
View Article and Find Full Text PDFAims: Robotic magnetic navigation (RMN) provides increased catheter precision and stability. Formerly, only the CARTO 3 mapping system was integrated with the RMN system (CARTO-RMN). Recently, a novel high-resolution non-contact mapping system (AcQMap) has been integrated with the RMN system (AcQMap-RMN) for the treatment of atrial fibrillation (AF) and atrial tachycardias (AT).
View Article and Find Full Text PDFJ Interv Card Electrophysiol
November 2022
Background: Recently, a novel integrated dilator-needle system (AcQCross Qx, Acutus Medical) was introduced to reduce the number of exchanges for a transseptal access. This system can be used in combination with large bore sheaths. In this pilot study, we evaluated the safety and efficacy of a zero-exchange approach with the AcQCross system in cryoballoon procedures.
View Article and Find Full Text PDFBackground: Sleep-disordered breathing (SDB) may hamper the outcome of catheter ablation of atrial fibrillation (AF). However, SDB is underdiagnosed in clinical practice and the relevancy of undiagnosed SDB on the outcome of catheter ablation is unclear.
Objective: To evaluate if undiagnosed SDB has an impact on AF recurrence after catheter ablation.
The clinical value of non-invasive mapping system depends on its accuracy under common variations of the inputs. The View Into Ventricular Onset (VIVO) system matches simulated QRS complexes of a patient-specific anatomical model with a 12-lead ECG to estimate the origin of ventricular arrhythmias. We aim to test the performance of the VIVO system and its sensitivity to changes in the anatomical model, time marker placement to demarcate the QRS complex and body position.
View Article and Find Full Text PDFBackground: Insertable cardiac monitors (ICMs) are increasingly used to evaluate the atrial fibrillation (AF) burden after catheter ablation of AF. BioMonitor III (BM3) is an ICM with a long sensing vector, which enhances sensing capabilities. The AF detection algorithm of the BM3 is based on R-R interval variability.
View Article and Find Full Text PDFBackground: Direct oral anticoagulants (DOACs) are the preferred choice of oral anticoagulation in patients with atrial fibrillation (AF). Randomized trials have demonstrated the efficacy and safety of DOAC in patients undergoing a cardiac implantable electronic device procedure (CIED); however, there is limited real-world data.
Objective: To evaluate the outcome of patients undergoing an elective CIED procedure in a tertiary referral center with an interrupted DOAC or continued vitamin K antagonist (VKA) regimen.
Background: Persistent phrenic nerve palsy (PNP) is an established complication of atrial fibrillation (AF) ablation, especially during cryoballoon and thoracoscopic ablation. Data on persistent PNP reversibility is limited because most patients recover <24 h. This study aims to investigate persistent PNP recovery, freedom of PNP-related symptoms after AF ablation and identify baseline variables associated with the occurrence and early PNP recovery in a large nationwide registry study.
View Article and Find Full Text PDFAblation procedures using classical sequential mapping systems may fail to eliminate IAST. The AcQMap dipole charge density mapping technique may offer improved accuracy and has a potential added value for the ultimate success of eliminating IAST. The use of the AcQMap should be considered for redo, as well as first line therapy for patients with symptomatic IAST.
View Article and Find Full Text PDFObjective: Patients with heart disease are at increased risk for sudden cardiac death. Guidelines recommend an implantable loop recorder (ILR) for symptomatic patients when symptoms are sporadic and possibly arrhythmia-related. In clinical practice, an ILR is mainly used in patients with unexplained syncope.
View Article and Find Full Text PDFBackground: Little is known about the last phase of life of patients with implantable cardioverter defibrillators and the practice of advance care planning in this population.
Aim: To describe the last phase of life and advance care planning process of patients with an implantable cardioverter defibrillator, and to assess relatives' satisfaction with treatment and care.
Design: Mixed-methods study, including a survey and focus group study.
Introduction: Recently a novel cryoballoon system (POLARx, Boston Scientific) became available for the treatment of atrial fibrillation. This cryoballoon is comparable with Arctic Front Advance Pro (AFA-Pro, Medtronic), however, it maintains a constant balloon pressure. We compared the procedural efficacy and biophysical characteristics of both systems.
View Article and Find Full Text PDFBackground: Direct oral anticoagulants (DOACs) have emerged as the preferred choice of oral anticoagulation in patients with atrial fibrillation. Randomized trials have demonstrated the efficacy and safety of DOAC in patients undergoing electrical cardioversion (ECV); however, there is limited real-world data.
Objective: To evaluate the outcome of patients undergoing an elective ECV for atrial tachyarrhythmia in a tertiary referral center who were treated with DOAC or vitamin K antagonist (VKA) without routine trans esophageal echocardiography (TEE).
Aims: Pulmonary vein isolation (PVI) has become a cornerstone of the invasive treatment of atrial fibrillation. Severe complications are reported in 1-3% of patients. This study aims to compare complications and follow-up outcome of PVI in patients with atrial fibrillation.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
November 2021
Purpose: During transvenous lead extraction (TLE), the femoral snare has mainly been used as a bail-out procedure. The purpose of the present study is to evaluate the efficacy and safety of a TLE approach with a low threshold to use a combined superior and femoral approach.
Methods: This is a single-center observational study including all TLE procedures between 2012 till 2019.
Background: Catheter ablation is an important therapeutic option for atrial tachycardias in patients with CHD. As a result of extensive scarring and surgical repair, multiple intra-atrial re-entrant tachycardia circuits develop and serve as a substrate for arrhythmias. The best ablation approach for patients with multiple intra-atrial re-entrant tachycardias has not been investigated.
View Article and Find Full Text PDFPurpose: Pulmonary vein isolation (PVI) using cryoballoon (CB) ablation is associated with an increased radiation exposure compared with radiofrequency ablation. Previous studies showed that radiation exposure in CB PVI can be reduced by optimizing the fluoroscopy protocol without comprising acute efficacy and safety. We evaluated the mid-term outcome of a modified fluoroscopy protocol in patients undergoing CB PVI.
View Article and Find Full Text PDFBackground: Sudden cardiac death (SCD) due to ventricular arrhythmias (VA) is an important mode of death in adults with congenital heart disease (CHD). Risk stratification is difficult in this heterogeneous population. Insertable cardiac monitors (ICM) may be useful for risk stratification.
View Article and Find Full Text PDF