Purpose: This study aimed to investigate the long-term outcomes of patients with a femoral neck fracture (FNF), treated with the Dynamic Locking Blade Plate (DLBP).
Methods: Retrospective analysis of prospectively collected data of a multicentre cohort of patients with FNFs was conducted, regarding the long-term incidence of revision surgery after DLBP. Implant failure was evaluated using Kaplan-Meier and Cox regression analysis.
Introduction: This systematic review aims to provide an overview of predictors for failure of treatment of displaced femoral neck fracture (dFNF) with internal fixation and quantify their risk of fixation failure in a meta-analysis.
Patients And Methods: PubMed, Embase, Web of Science, Cochrane Library, and EMCare were searched for original studies published from January 2000, including adult patients with an internally fixated dFNF, that reported data on predictors for fixation failure defined as revision surgery due to non-union, avascular femoral head necrosis or cut-out of implant. RevMan version 5 software was used to pool univariable Odds Ratio's (OR) for predictors of fixation failure by means of a random effects model.
Background: The Dynamic Locking Blade Plate (DLBP) was recently introduced for fixation of displaced femoral neck fractures (FNF) and has been well received. Although the results of this implant in young patients are promising, the DLBP has not yet been compared to a standard device such as the Dynamic Hip Screw (DHS). The aim of this study is to compare the clinical outcome and costs of displaced FNF treated with internal fixation by means of either the DLBP or the DHS in patients up to 65 years of age.
View Article and Find Full Text PDFIntroduction: Posterior tilt of the femoral head in femoral neck fractures (FNF) may influence stability of the fracture and may therefore affect the treatment outcome. Posterior tilt can be measured with different methods. The Lateral Garden Angle (LGA) has been used for this purpose for decades and more recently the Posterior Tilt Measurement (PTM) was introduced.
View Article and Find Full Text PDFAims: The objective of this study was to investigate bone healing after internal fixation of displaced femoral neck fractures (FNFs) with the Dynamic Locking Blade Plate (DLBP) in a young patient population treated by various orthopaedic (trauma) surgeons.
Patients And Methods: We present a multicentre prospective case series with a follow-up of one year. All patients aged ≤ 60 years with a displaced FNF treated with the DLBP between 1st August 2010 and December 2014 were included.
Importance: Following clean (class I, not contaminated) surgical procedures, the rate of surgical site infection (SSI) should be less than approximately 2%. However, an infection rate of 12.2% has been reported following removal of orthopedic implants used for treatment of fractures below the knee.
View Article and Find Full Text PDFBackground: Approximately 17 % of all fractures involve the distal radius. Two-thirds require reduction due to displacement. High redislocation rates and functional disability remain a significant problem after non-operative treatment, with up to 30 % of patients suffering long-term functional restrictions.
View Article and Find Full Text PDFEur J Trauma Emerg Surg
August 2017
Background: This study evaluated the clinical results of a new implant in the internal fixation of undisplaced femoral neck fractures.
Method: Irrespective of their age, 149 patients with undisplaced (Garden I and II) femoral neck fractures were included in a prospective multicentre clinical cohort study and were treated by internal fixation by means of the Dynamic Locking Blade Plate (DLBP). The mean age was 69 years and the follow-up at least one year.
Background: In the Netherlands about 18,000 procedures with implant removal are performed annually following open or closed reduction and fixation of fractures, of which 30-80% concern the foot, ankle and lower leg region. For clean surgical procedures, the rate of postoperative wound infections (POWI) should be less than ~2%. However, rates of 10-12% following implant removal have been reported, specifically after foot, ankle and lower leg fractures.
View Article and Find Full Text PDFBackground: Fractures of the humeral shaft are associated with a profound temporary (and in the elderly sometimes even permanent) impairment of independence and quality of life. These fractures can be treated operatively or non-operatively, but the optimal tailored treatment is an unresolved problem. As no high-quality comparative randomized or observational studies are available, a recent Cochrane review concluded there is no evidence of sufficient scientific quality available to inform the decision to operate or not.
View Article and Find Full Text PDFBackground And Aim: Open reduction and internal fixation (ORIF) of intra-articular calcaneal fractures through an extended lateral approach is frequently accompanied by a high complication rate. However, ORIF currently provides the best long-term clinical results. The aim of this study was twofold: (1) to evaluate both mid- to long-term clinical and radiological results of a consecutive series treated by ORIF and (2) to determine the influence of short-term complications on long-term clinical outcome.
View Article and Find Full Text PDFA 51-year-old man developed burn wounds on both knees after finishing a cement floor. Cement burns are caused by wet cement, which is highly alkaline Initial treatment consists of lavage. Further management can be conservative but in full thickness injuries excision and grafting should be considered.
View Article and Find Full Text PDFBackground: Elbow dislocations can be classified as simple or complex. Simple dislocations are characterized by the absence of fractures, while complex dislocations are associated with fractures. After reduction of a simple dislocation, treatment options include immobilization in a static plaster for different periods of time or so-called functional treatment.
View Article and Find Full Text PDFIntroduction: The osteosynthesis of intracapsular hip fractures results in a 19-48% failure rate. Only when the anatomical reduction is secured by stable fixation, revascularisation of the femoral head can take place and the fracture can heal by primary osteonal reconstruction. The common implants lack rotational and/or angular stability.
View Article and Find Full Text PDFBackground: Fractures of the proximal humerus are associated with a profound temporary and sometimes permanent, impairment of function and quality of life. The treatment of comminuted fractures of the proximal humerus like selected three-or four-part fractures and split fractures of the humeral head is a demanding and unresolved problem, especially in the elderly. Locking plates appear to offer improved fixation; however, screw cut-out rates ranges due to fracture collapse are high.
View Article and Find Full Text PDFInternal fixation of intracapsular hip fractures results in a high failure rate with non-union and avascular necrosis being the two most important complications. In order to prevent these possible complications treatment should consist of an anatomical reduction and stable fixation by insertion of a low volume, dynamic implant, providing angular and rotational stability to the femoral head. According to these principles a new implant, the dynamic locking blade plate (DLBP) was designed for the fixation of intracapsular hip fractures.
View Article and Find Full Text PDFPurpose: To evaluate the end results of arthroscopically assisted osteosynthesis of tibial plateau fractures in patients older than 55 years of age.
Type Of Study: Case series.
Methods: Over a 5-year period, 201 consecutive patients presented with tibial plateau fracture; 131 of these patients were treated with arthroscopically assisted osteosynthesis of the tibial plateau.
Ned Tijdschr Geneeskd