Publications by authors named "Rodrigo P B Costa-Felix"

In this work, high frequency and low power ultrasound without external heating source and mechanical stirring in biodiesel production were studied. Transesterification of soybean oil with methanol and catalyzed by KOH was investigated using ultrasound equipment and ultrasonic transducer. The effect of ultrasonic output power (3 W-9 W), ultrasonic frequency (1 MHz and 3 MHz), and alcohol to oil molar ratio (6:1 and 8:1) have been investigated.

View Article and Find Full Text PDF

Speed of sound and attenuation are essential for characterizing reference materials such as biological tissue-mimicking materials (TMMs) used in ultrasonic applications. There are many publications on the manufacture of TMMs and the measurement of their properties. However, no studies in the literature have applied the metrological approach of International Organization for Standardization (ISO) Guide 35 to certify biological ultrasound TMMs as candidates for reference materials (RMs).

View Article and Find Full Text PDF

Healing therapies that make use of ultrasound are based on raising the temperature in biological tissue. However, it is not possible to heal impaired tissue by applying a high dose of ultrasound. The temperature of the tissue is ultimately the physical quantity that has to be assessed to minimize the risk of undesired injury.

View Article and Find Full Text PDF

The speed of sound and attenuation are important properties for characterizing reference materials such as biological phantoms used in ultrasound applications. There are many publications on the manufacture of ultrasonic phantoms and the characterization of their properties. However, few studies have applied the principles of metrology, such as the expression of the uncertainty of measurement.

View Article and Find Full Text PDF

Thermochromic test bodies are promising tools for qualitatively evaluating the acoustic output of ultrasound physiotherapy systems. Here, a novel phantom, made of silicone mixed with thermochromic powder material, was developed. Additionally, a procedure was developed to evaluate the stability and homogeneity of the phantom in a metrologic and statistical base.

View Article and Find Full Text PDF

The transducers of diagnostic ultrasonic equipment generate undesired local heating at the applied part of the transducer surface. The assessment of this heating is fundamental in warranting patient safety. On the standard IEC 60601-2-37, methods have been established for the reliable measurement of heating, where three tissue models based on tissue-mimicking materials are recommended: soft tissue mimic only, bone mimic close to the surface of soft tissue, and skin mimic at the surface of soft tissue.

View Article and Find Full Text PDF

Therapeutic ultrasound (TU) has been used for the last 50 y in rehabilitation, including treatment of soft tissues. Ultrasound waves can be employed in two different modes of operation, continuous and pulsed, which produce both thermal and non-thermal effects. Despite the large-scale use of TU, there are few scientific studies on its biologic effects during skeletal muscle differentiation.

View Article and Find Full Text PDF

Ultrasonic beam parameters from nondestructive testing probes and respective measurement uncertainties were calculated according to the Guide to the Expression of Uncertainty in Measurement (BIPM-JCGM-100:2008). The major conclusion of this work is that proper measurements of ultrasonic probes parameters are necessary because each probe has intrinsic construction particularities. Uncertainty evaluation was essential to properly assess the experimental results.

View Article and Find Full Text PDF

This paper discloses results of measuring the effective radiating area (A(ER)) and the beam non-uniformity ratio (R(BN)) for US transducers at 5.0 MHz. Measurements were carried out at Laboratory of Ultrasound of the Brazilian National Institute of Metrology, Standardization, and Industrial Quality.

View Article and Find Full Text PDF