Publications by authors named "Rodrigo A de Medeiros"

Statement Of Problem: With advancements in digital technologies, the digital workflow has revolutionized the fabrication of occlusal devices through additive methods using 3-dimensional (3D) printing. However, an established protocol for polishing 3D printed occlusal devices is lacking, despite this step being crucial for minimizing surface porosity, material fatigue and preventing bacterial plaque accumulation, thereby contributing to device longevity.

Purpose: The purpose of this in vitro study was to evaluate the impact of polishing systems on the surface roughness and Vickers microhardness of heat-polymerizing acrylic resin and 3D printing resins used for occlusal devices.

View Article and Find Full Text PDF

Background: Considering the development of new 3D printing technologies that use different printing techniques, further studies must be conducted to evaluate the impact of different printing systems on the mechanical properties of 3D-printed materials. This study aimed to evaluate the mechanical properties of 3D-printed materials for occlusal devices using different 3D printers and printing layer thicknesses.

Material And Methods: Ninety rectangular samples were manufactured and divided into nine groups according to the 3D printer model they were printed on (AnyCubic Mono X, Elegoo Mars 2, or FlashForge Hunter) and the layer thickness (20, 50, or 100 µm) and were subjected to superficial microhardness, flexural resistance, and elasticity modulus tests.

View Article and Find Full Text PDF

Objective: Assess the prevalence of self-reported TMD symptoms and anxiety and check the quality of sleep and life during the distance learning period in university students at the University of Brasilia (UnB).

Materials And Methods: The participants were students from the Health Sciences College and Medicine College at UnB. Self-administered questionnaires were used to evaluate symptoms of TMD, quality of life, and sleep quality.

View Article and Find Full Text PDF

Objective: This study reports a clinical case of rehabilitation of a patient who had her left little finger amputated at the mesial phalanx because of a gunshot wound. The finger prosthesis was custom- made using a silicone.

Case Description: This study presents a clinical case of a female patient who had her left little finger amputated at the mesial phalanx because of a gunshot wound in 2016.

View Article and Find Full Text PDF

Purpose: To investigate the influence of nonthermal plasma (NTP) treatment on the tensile bond strength between heat-polymerized acrylic resin for ocular prostheses and silicone reliner, with and without the use of an adhesive primer.

Materials And Methods: One-hundred and sixty-four acrylic resin specimens were fabricated and randomly distributed into four groups according to the type of surface treatment: Sofreliner Primer, NTP, Sofreliner Primer + NTP, and NTP + Sofreliner Primer. Two specimens interposed with relining material (Sofreliner) formed one test sample to perform the tensile bond strength tests, before (initial) and after storage (final) in saline solution (37°C, 90 days, n = 10).

View Article and Find Full Text PDF

Background: The aim was to analyze the levels of stress of edentulous patients through the state-trait anxiety inventory (STAI) and salivary flow through the visual analogue scale (VAS) xerostomia questionnaire, as well as analyze the levels of cortisol, capillary blood glucose, and blood pressure (BP) before and after the installation of complete dentures.

Methods: Fifty patients were evaluated. The STAI and VAS xerostomia questionnaire were applied before the installation of the prosthesis, on the day of its installation, and 1 month after the last recall visit.

View Article and Find Full Text PDF

In some clinical situations, the clinician may encounter previously installed implants that should be associated with other implants for a proper rehabilitation. The aim of this study was to evaluate the biomechanical behaviour of a multiple prosthesis joined by different implant connections using photoelasticity. Photoelastic models with a screwed fixed prosthesis supported by implants with different connection systems (Morse taper, external hexagon, internal hexagon, and Flexcone), and different combinations among them, were fabricated.

View Article and Find Full Text PDF

New systems are released in the odontological market with the objective of bringing improvements and advancements in the clinical success of implants and implant-supported prostheses. The distribution of tension for the bone/implant system of these new systems is important. The purpose of this work was to evaluate, by photoelastic analysis and strain gauges, the distribution of tension for the bone/implant system, using the Slim system.

View Article and Find Full Text PDF

Purpose: The aim of this study was to assess stress distribution in the bone-implant interface of a mandibular implant-supported prosthesis with different cantilever lengths, aesthetic coating materials, and implant abutments.

Materials And Methods: A photoelastic model of an edentulous mandible, containing 5 external hexagon implants, was constructed. Experimental models were divided into 6 groups: group 1-UCLA component and metal bar; group 2-UCLA component and acrylic resin coating; group 3-UCLA component and porcelain coating; group 4-abutment and metal bar; group 5-abutment and acrylic resin coating; and group 6-abutment and porcelain coating.

View Article and Find Full Text PDF

Statement Of Problem: The rehabilitation of patients after a maxillectomy involves the use of an obturator to seal oral-nasal-sinus communication and to facilitate mastication, swallowing, and speech.

Purpose: The purpose of this in vitro study was to evaluate different attachment systems used for implant-retained obturators at dissipation loads and under shear forces.

Material And Methods: Photoelastic models were fabricated with 3 external hexagon implants at the incisor, canine, and first molar regions.

View Article and Find Full Text PDF

Short dental implants have been used as an attempt to avoid bone grafts surgery, however there are few literature reports that evaluate changes to their design. Therefore, the aim of this study was to assess the effect of different short implant design on stress distribution through photoelastic analysis. Six external hexagon (5 × 5 mm) short dental implants with different design were used.

View Article and Find Full Text PDF

The aim of this study was to evaluate the influence of pigment incorporation on the cytotoxicity of ocular prosthesis N1 color acrylic resin. Nine samples were manufactured by heat-polymerization in water bath and divided into 3 groups: acrylic resin without pigment incorporation (group R), acrylic resin with pigment incorporation (group RP), and acrylic pigment (group P). Eluates formed after 72h of sample immersion in medium were incubated with conjunctival cell line (Chang conjunctival cells) for 72h.

View Article and Find Full Text PDF

Statement Of Problem: Different factors can influence marginal bone loss around dental implants, including the type of internal and external connection between the implant and the abutment. The evidence needed to evaluate these factors is unclear.

Purpose: The purpose of this systematic review was to evaluate marginal bone loss by radiographic analysis around dental implants with internal or external connections.

View Article and Find Full Text PDF

Aim: Epidermolysis bullosa (EB) represents a highly rare subgroup of skin diseases that affects skin and mucous membrane. The aim of the present study was to assess caries prevalence and its associated factors in EB subjects. Salivary status was also assessed.

View Article and Find Full Text PDF

Photoelastic analysis was used to evaluate the biomechanical behaviour of implant-supported, double-screwed crowns with different connection systems and cantilever lengths. Three models were made in PL-2 photoelastic resin and divided into six groups, on the basis of the implant connection system (external hexagon [EH] or Morse taper [MT]), type of abutment (Mini Pilar [Neodent, Curitiba, Paraná, Brazil] or "UCLA") and number of crowns in the cantilever (one or two). The implant-prosthesis unit was placed in a circular polariscope.

View Article and Find Full Text PDF

Purpose: To analyze whether immersion in sodium fluoride (NaF) solutions and/or common acidic beverages (test solutions) would affect the surface roughness or topography of lithium disilicate ceramic.

Methods: 220 ceramic discs were divided into four groups, each of which was subdivided into five subgroups (n = 11). Control group discs were immersed in one of four test beverages for 4 hours daily or in artificial saliva for 21 days.

View Article and Find Full Text PDF

The aim of this study was evaluate the biomechanical behaviour of prostheses screwed into conventional (0° angulation) and pre-angled experimental (8, 12 and 20°) external hexagon implants (13 × 4 mm) by photoelastic analysis. Eight casts were made in photoelastic resin. Casts were divided into groups of single crowns or three combined elements.

View Article and Find Full Text PDF
Article Synopsis
  • The treatment of orofacial tumors can lead to facial deformities, impacting functions like feeding and speech, and diminishing self-esteem.
  • A case study of a male patient with epidermoid cancer involved a mandibulectomy and the creation of conventional and removable dentures, which improved his ability to feed and overall satisfaction after one year.
  • Effective prosthetic rehabilitation is crucial for self-esteem post-surgery, and well-fitted dentures with proper occlusal adjustments can enhance stability and retention, especially in patients with adequate alveolar bone.
View Article and Find Full Text PDF

The success of rehabilitation will not depend on just clinical procedures. A proper dental technique (ceramist) is required as well as the respect for some biomimetic principles to obtain the desired final result. This study has the purpose of describing a prosthetic rehabilitation with laminate veneers and all-ceramic crowns of a patient unsatisfied with a previous esthetic treatment because of the negligence of some biomimetic principles.

View Article and Find Full Text PDF

Introduction: The aim of this paper was to present a rehabilitation of a patient with a dynamic universal castable long abutment (UCLA) for a single tilted implant in the anterior maxillary area.

Presentation Of Case: A 57-year-old male patient attended the dentistry college clinic complaining of a vertical fracture of a residual root of the dental element 22. The tooth extraction was indicated for the implant installation.

View Article and Find Full Text PDF

Statement Of Problem: Surface transformation with nonthermal plasma may be a suitable treatment for dental ceramics, because it does not affect the physical properties of the ceramic material.

Purpose: The purpose of this study was to characterize the chemical composition of lithium disilicate ceramic and evaluate the surface of this material after nonthermal plasma treatment.

Material And Methods: A total of 21 specimens of lithium disilicate (10 mm in diameter and 3 mm thick) were fabricated and randomly divided into 3 groups (n=7) according to surface treatment.

View Article and Find Full Text PDF

The gastroesophageal reflux disease (GERD) is one of the main causes of dental erosion. The aim of this case presented is to describe the prosthetic rehabilitation of a patient with GERD after 4 years of followup. A 33-year-old male patient complained about tooth sensitivity.

View Article and Find Full Text PDF

Aim: The aim of this study is to evaluate through a literature review, the soft tissue response in contact with zirconia abutments, including case reports comparing prosthetics rehabilitations with zirconia and titanium abutments upto 3 years of follow-up as well as the factors that should be considered on implant's abutment selection.

Background: Metallic abutments can provide grayish color when in contact with thin soft tissues which may lead the implant prosthetic treatment to failure. In this context, the abutments of zirconia stand out because there is an excellent linking between esthetics and the health of peri-implant soft tissues.

View Article and Find Full Text PDF

Ocular prostheses are important determinants of their users' aesthetic recovery and self-esteem. Because of use, ocular prostheses longevity is strongly affected by instability of the iris color due to polymerization. The goal of this study is to examine how the color of the artificial iris button is affected by different techniques of artificial wear and by the application of varnish following polymerization of the colorless acrylic resin that covers the colored paint.

View Article and Find Full Text PDF