Groundwater is the most ubiquitous source of liquid freshwater globally, yet its role in supporting diverse ecosystems is rarely acknowledged. However, the location and extent of groundwater-dependent ecosystems (GDEs) are unknown in many geographies, and protection measures are lacking. Here, we map GDEs at high-resolution (roughly 30 m) and find them present on more than one-third of global drylands analysed, including important global biodiversity hotspots.
View Article and Find Full Text PDFEmissions reductions may not meet expectations, and groundwater use will likely increase.
View Article and Find Full Text PDFThe current study investigates the body-environment interaction and exploits the passive viscoelastic properties of the body to perform undulatory locomotion. The investigations are carried out using a mathematical model based on a dry frictional environment, and the results are compared with the performance obtained using a physical model. The physical robot is a wheel-based modular system with flexible joints moving on different substrates.
View Article and Find Full Text PDFOne of the oldest yet most common modalities of locomotion known among limbless animals is undulatory, also recognized for its stability compared to legged locomotion. Multiple forms of active mechanisms, e.g.
View Article and Find Full Text PDFInnate immune cells infiltrate growing adipose tissue and propagate inflammatory clues to metabolically distant tissues, thereby promoting glucose intolerance and insulin resistance. Cytokines of the IL-6 family and gp130 ligands are among such signals. The role played by oncostatin M (OSM) in the metabolic consequences of overfeeding is debated, at least in part, because prior studies did not distinguish OSM sources and dynamics.
View Article and Find Full Text PDFPurpose: To compare the objective and subjective outcomes between the extended depth of focus (EDOF) Mini Well intraocular lens (IOL) and the aspheric monofocal Mini-4-Ready IOL (both SIFI S.p.A.
View Article and Find Full Text PDFPurpose: To evaluate the safety and efficacy of double compared to single intraluminal suture stenting in reducing early postoperative hypertensive spikes (HS) and hypotony after Baerveldt glaucoma implant surgery.
Methods: For this retrospective study, we reviewed the medical charts of 60 patients (60 eyes) who underwent Baerveldt drainage device surgery between 2017 and 2019. Two groups were formed according to whether a single suture stent was placed within the tube (5-0 polypropylene, 30 eyes, group 1) or a double suture (5-0 and 6-0 polypropylene, 30 eyes, group 2).
Purpose: To evaluate and compare the objective and subjective outcomes between bilateral implantation of the extended depth of focus (EDOF) Mini Well intraocular lens (IOL) and the aspheric monofocal Mini-4-Ready IOL (both SIFI S.p.A.
View Article and Find Full Text PDFBackground: Detecting recent HIV infections is important to evaluate incidence and monitor epidemic trends. We aimed to evaluate the diagnostic performance and accuracy of the avidity index (AI) for discriminating for recent HIV infections.
Methods: We collected serum samples from HIV-1 positive individuals: A) with known date of infection (midpoint in time between last HIV-negative and first HIV-positive test); B) infected for >1 year.
Reactivation of the hepatitis B virus (HBV) has been reported in patients with occult infection (OBI), i.e. HBV surface antigen (HBsAg) negative, HBV core antibody (anti-HBc) positive ± antibodies against HBsAg (anti-HBs) and detectable HBV DNA in serum or liver, receiving immunosuppressive or cytotoxic therapies.
View Article and Find Full Text PDFBackground: Early detection of undiagnosed HIV infected patients is of paramount importance. The attitude of Italian hospital-based Internal Medicine physicians to prescribe HIV testing following the detection of HIV-associated signs, symptoms and behaviours (triggers) has been reported to be poor. The aim of the study is to quantify the extent of the missed opportunities for early HIV diagnosis in Internal Medicine Departments (IMD).
View Article and Find Full Text PDFBackground: Testing for hepatitis C virus core antigen (HCV Ag) may represent a complementary tool to anti-HCV and HCV-RNA in the diagnosis and monitoring of HCV infection.
Objective: To evaluate the performance characteristics of the automated Abbott ARCHITECT HCV Ag assay.
Study Design: Five sites analyzed over 3000 routine serum samples from populations at different risk, comparing HCV Ag results with anti-HCV screening and supplemental assay results and with HCV-RNA.
The development of assays for detecting recent HIV infections has become crucial for analyzing trends in infection in different populations, both for surveillance and prevention activities. The anti-HIV avidity index (AI), measured with third-generation immunoassays (which detect anti-HIV antibody), has been shown to be an accurate tool for discriminating recent HIV infections (<6 months) from established infections (≥ 6 months). We compared a third-generation immunoassay (AxSYM HIV 1/2 gO; Abbott Diagnostics) to a fourth-generation immunoassay (Architect HIV Ag/Ab Combo; Abbott Diagnostics; which detects anti-HIV antibody and p24 antigen) in terms of AI performance in distinguishing between recent and established HIV infections.
View Article and Find Full Text PDFAIDS Patient Care STDS
June 2008
There is a lack of updated estimates of HIV-2 infection in Italy. Moreover, lack of standardized HIV-2 viral load (VL) and drug resistance tests challenges clinical practice. Among 2941 HIV-positive patients followed in our center (Brescia, Northern Italy), 220 (7.
View Article and Find Full Text PDFHepatitis-associated aplastic anemia (HAA) is characterized by marrow failure developing after acute seronegative hepatitis. A patient with agammaglobulinemia developed HAA in association with HBsAg-negative, hepatitis B virus (HBV) DNA-positive acute hepatitis. Sequence analysis showed several substitutions in the major antigenic determinant of HBsAg, potentially affecting the detection by diagnostic immunoassays.
View Article and Find Full Text PDFBackground And Objectives: We evaluated hepatitis B virus (HBV) serological markers by novel, quantitative immunoassays in order to study their behaviours and possible role in the various phases of HBV infection.
Study Design: The quantitative determination of HBsAg and anti-HBc/IgM by chemiluminescent immunoassays (Abbott Architect) and the calculation of anti-HBc avidity index have been carried out on repository specimens from patients with acute or chronic hepatitis B.
Results: In acute hepatitis the levels of HBsAg were generally >10,000 UI/mL and decreased sharply in the recovery phase.
Forty-four anti-HIV seropositive pregnant women were enrolled in a study of maternal factors related to mother-to-infant human immunodeficiency virus type 1 (HIV-1) transmission. HIV-1 infection was documented in 11 of 45 infants (24.4%).
View Article and Find Full Text PDFBackground/aims: Hepatitis delta virus (HDV) coinfection is frequent in patients infected with human immunodeficiency virus (HIV), and it may cause death independently of the development of full-blown AIDS. In order to evaluate the efficacy and tolerability of interferon alpha in the treatment of hepatitis delta in HIV-infected patients, and to compare them with those observed in anti-HIV-seronegative patients, we carried out an open uncontrolled trial on 21 HIV-uninfected and 16 HIV-infected patients without severe immunodeficiency.
Methods: All patients were treated with recombinant interferon alpha 2b (IFN) at doses of 10 million units thrice weekly for 6 months, and 6 million units thrice weekly for an additional 6 months.
Seventy-five women with anti-hepatitis C virus (HCV) antibody were enrolled prospectively during pregnancy or at delivery for study of mother-to-child transmission of HCV. Twenty-three women were coinfected with the human immunodeficiency virus (HIV). Seventy babies were monitored for at least 6 months.
View Article and Find Full Text PDFJ Clin Microbiol
December 1994
We have evaluated the clinical significance of hepatitis C virus (HCV) RNA determination by analyzing a group of 221 hospitalized patients with abnormal liver function tests. Serum HCV RNA was detected by "nested" PCR amplification followed by nonisotopic hybridization. Of the 200 (90.
View Article and Find Full Text PDFTo investigate the mechanism underlying the release of atrial natriuretic peptide (ANP) in in vitro condition, isolated, superfused rat atria were subjected to adrenergic, chronotropic, and mechanical stimulation. First administration of isoproterenol (Iso; either 10(-9) or 10(-6) M) caused a release of ANP, which was transient. Subsequent increments in concentration of Iso always resulted in a much lower release of ANP, despite the increased effects on the mechanical function of the atria.
View Article and Find Full Text PDFAim of the study was to evaluate the effect of cardiopulmonary receptors activation and deactivation on antidiuretic hormone (ADH) and atrial natriuretic peptide (ANP) incretion in hypertensive and normotensive subjects. Twenty-one male subjects, 7 normotensives and 14 mild hypertensives, 7 without and 7 with left ventricular hypertrophy (LVH) were admitted to the study. Each subject underwent selective loading and unloading of cardiopulmonary receptors, by application of a positive (LBPP) or negative (LBNP) pressure to the lower body.
View Article and Find Full Text PDFThe aim of our study was to confirm by Recombinant Immunoblot Assay (RIBA) and by neutralization assay the repeat positive reactions found by two commercially available EIAs (Ortho and Abbott) when testing samples from volunteer blood donors, patients with chronic liver disease and with hepatocellular carcinoma. Our data show a high confirmatory rate among patients with chronic viral NANBH and HCC, while among donors and patients with CLD other than NANBH the percentage of presumptive EIA positive reactions confirmed by RIBA and/or neutralization assay is much lower. In our experience, the neutralization assay appears to be somewhat more sensitive than RIBA, especially when samples show low EIA optical densities.
View Article and Find Full Text PDF