Background: The aim of this study was to report the results of a single-centre experience with a new generation balloon expandable stent-graft (Viabahn VBX; W. L. Gore & Associates, Flagstaff, AZ, USA) as bridging stent in branched endovascular aortic repair (B-EVAR).
View Article and Find Full Text PDFBackground: Endovascular repair of complex abdominal aortic aneurysms (CAAAa) and thoracoabdominal aortic aneurysms (TAAAs) with fenestrated and branched devices (F/BEVAR) represents the first-line treatment in old or unfit patients. Currently, the widespread diffusion of these techniques has led to a progressive increase of complex endovascular procedures also in younger and fitter patients, but the related results have been only minimally reported, without long-term data. We investigated the long-term results of F/BEVAR for CAAA and TAAA repair in young and fit patients.
View Article and Find Full Text PDFObjective: The aim of this study was to report the outcomes of endovascular urgent thoracoabdominal aortic (TAAA) repair, using an off-the-shelf preloaded inner branch device (E-nside; Artivion).
Methods: Data from a physician-initiated national multicenter registry, including patients treated with E-nside endograft (INBREED) were prospectively collected (2020-2024); only urgent cases were included in this study. Primary outcomes were technical success and mortality at 30 days.
Eur J Vasc Endovasc Surg
July 2024
Objective: This study aimed to compare two commercially available off the shelf branched endografts for thoraco-abdominal aortic aneurysm (TAAA) repair, namely the E-nside (Artivion) and Zenith t-Branch (Cook Medical) devices.
Methods: This multicentre retrospective study (2020 - 2023) included patients treated by branched endovascular aortic repair (BEVAR) for TAAA using the inner branched E-nside or the outer branched t-Branch. Endpoints were 30 day technical success and major adverse events (MAEs) as well as one year freedom from target vessel instability and main endograft instability.
Background: Endovascular treatment is nowadays accepted as first-line treatment for most patients with aorto-iliac obstructive disease (AIOD), including those with Trans-Atlantic Inter-Society Consensus II (TASC-II) lesion types C and D. Aim of the study was to evaluate the role of Viabahn VBX (W. L.
View Article and Find Full Text PDFBackground: By this survey, we aim to gain national-based information regarding trends in endovascular repair (ER) for the treatment of aortic disease in patients with genetically-triggered aortic disease (GTAD) and connective tissue disorder (CTD) over the last two decades.
Methods: All Italian vascular surgery centers (N.=80) were invited to participate in an anonymous electronic cross-sectional survey on ER for GTAD/CTD.
Objective: The aim of the study was to compare the early and medium-term outcomes of bypass vs endovascular treatment of occluded femoro-popliteal stents in patients with chronic limb-threatening ischemia (the OUT-STEPP multicentric registry).
Methods: Between January 2016 and December 2021, 317 patients in 14 centers underwent treatment for a symptomatic occlusion of femoro-popliteal stent/stents. One hundred sixty-one patients were included into the present study: 46 (28.
Objective: Analyze the outcomes of endovascular complex abdominal and thoracoabdominal aortic aneurysm repair using the Cook fenestrated device with the modified preloaded delivery system (MPDS) with a biport handle and preloaded catheters.
Methods: A multicenter retrospective single arm cohort study was performed, including all consecutive patients with complex abdominal aortic aneurysm repair and thoracoabdominal aortic aneurysms treated with the MPDS fenestrated device (Cook Medical). Patient clinical characteristics, anatomy, and indications for device use were collected.
Acute limb ischemia (ALI) can be a devastating clinical emergency with potentially limb- or life-threatening consequences. It is defined as a quickly developing or sudden decrease in limb perfusion producing new or worsening symptoms and signs, often threatening limb viability. ALI is commonly related to an acute arterial occlusion.
View Article and Find Full Text PDFObjective: The use of steerable sheaths to allow total transfemoral access (TFA) of branched endovascular repair (BEVAR) of thoracoabdominal aortic aneurysms has been proposed as an alternative to upper extremity access (UEA); however, multicenter results from high-volume aortic centers are lacking.
Materials And Methods: The Total Transfemoral Branched Endovascular Thoracoabdominal Aortic Repair (TORCH2) study is a physician-initiated, national, multicenter, retrospective, observational registry (Clinicaltrials.gov identifier: NCT04930172) of patients undergoing BEVAR with a TFA for the cannulation of reno-visceral target vessels (TV).
Introduction: The complexity of the peripheral recanalization comes from the difficulty to cross the lesion or get into the subintimal space and its re-entry afterward, with a high risk of complications like artery dissection and/or rupture, which are life-threatening complications. To our knowledge, we report the first case of the use of a homemade steerable sheath for the successful revascularization of a heavy chronic total occlusion in a patient with unsuitable upper vascular access.
Technique: By contralateral vascular access and the use of a 6Fr 55-cm Cook Flexor sheath and a pre-looped 0.
Objectives: To assess the outcomes of Cook t-Branch off-the-shelf multibranched stent graft in the treatment of complex aortic aneurysms with narrow internal aortic lumen.
Methods: Between 2016 and 2020, 48 patients (mean age, 73 years) underwent elective or urgent or emergent Cook t-Branch implantation for thoracoabdominal or para/juxtarenal aortic aneurysms in two Italian vascular centers. Among these, 20 patients presented a paravisceral or pararenal luminal diameter of less than 25 mm.
The aim of this paper is to describe a case of complete transfemoral approach for endovascular treatment of a large intercostal patch aneurysm with custom-made stent-graft in a patient with Loeys-Dietz syndrome and previous multiple aortic operations. Three aortic components were used to exclude a 65-mm intercostal patch aneurysm. Because of the reimplantation site of supra-aortic trunks in a previous open arch repair, we used a complete transfemoral approach with a homemade steerable sheath to deliver all the renovisceral bridging stents through the downward side-branches.
View Article and Find Full Text PDFChemodectomas (CBTs) are the most frequently encountered tumours at the carotid bifurcation. Even if rare and commonly benign, their development close to the head and neck structures is often source of morbidity by compression and infiltration. Therefore, in order to avoid permanent neurologic or vascular complications these infrequent lesions need to be early removed.
View Article and Find Full Text PDFCarotid stenosis in the extracranial tract determines 10-15% of all ischaemic strokes. The aim of treatment, therefore, is to prevent major neurological events. Carotid endarterectomy surgery has proved effective in this regard, with various randomized studies that have demonstrated its validity in both symptomatic and asymptomatic patients.
View Article and Find Full Text PDFObjective: To report the results of a single-centre in the treatment of extensive aorto-iliac occlusive disease (AIOD) by the covered endovascular reconstruction of aortic bifurcation (CERAB) technique.
Methods: A retrospective analysis was conducted on data obtained from the review of medical charts of all consecutive patients treated with CERAB technique for AIOD between January 2016 and December 2019 in San Giovanni-Addolorata Hospital (Rome, Italy). Clinical examination, duplex ultrasound with ankle-brachial index measurement and contrast-enhanced computed tomography angiography were performed preoperatively.
Background: The aim of this study was to report the results of a multicenter experience on the use of adjunctive stents deployed inside abdominal aortic endografts with the purpose to prevent or treat limb occlusion after endovascular aneurysm repair (EVAR).
Methods: Between 2010 and 2018, there were 35 patients with aorto-iliac aneurysm presenting one or more risk factors for endograft limb occlusion (narrow aortic bifurcation and/or stenotic, highly angulated or occluded iliac arteries), who were treated with standard bifurcated stent graft reinforced by the means of a single model of balloon-expandable platinum/iridium bare stent (CP Stent; NuMED, Inc., Hopkinton, NY, USA).
Cardiovasc Intervent Radiol
October 2020
Purpose: To report early and mid-term results of post-aortic dissection thoracoabdominal aneurysms (pD-TAAA) treated by complex endografting in three tertiary referral hospitals.
Materials And Methods: A review of all patients with pD-TAAA unfit for open surgery treated with complex endovascular repair from 2012 to 2018 was performed. Simple thoracic endografts (TEVAR) were excluded.
Objective: The aim of this study was to evaluate early and late results of hybrid repair techniques for Kommerell's diverticulum (KD).
Methods: All patients who underwent hybrid repair (thoracic endovascular aortic repair + supra-aortic debranching) for KD between 2009 and 2018 were included in this retrospective multicenter study (three Italian centers). A proximal landing zone (PLZ) of at least 2 cm of healthy aorta was considered adequate for the deployment of a standard thoracic stent graft.
Acute abdominal arteriovenous fistulas in the setting of ruptured abdominal aortic aneurysms are a life-threatening condition; thus, a prompt diagnosis is required for proper treatment. Open, endovascular, and hybrid repair have been proposed for their management, with pros and cons for each method. In particular, the evolution of endoluminal techniques guarantees an increasing feasibility of these procedures, and a significant reduction in morbidity and mortality rates was usually associated with open surgery.
View Article and Find Full Text PDFObjectives: The aim of this study was to present a single-centre experience with EndoAnchors in patients who underwent endovascular repair for abdominal aortic aneurysms with challenging proximal neck, both in the prevention and treatment of endograft migration and type Ia endoleaks.
Methods: We retrospectively analysed 17 consecutive patients treated with EndoAnchors between June 2015 and May 2018 at our institution. EndoAnchors were applied during the initial endovascular aneurysm repair procedure (primary implant) to prevent proximal neck complications in difficult anatomies (nine patients), and in the follow-up after aneurysm exclusion (secondary implant) to correct type Ia endoleak and/or stent-graft migration (eight patients).
Secondary aorto-enteric fistulae (SAEF) are rare life-threatening complications that occur after abdominal aortic graft implant to treat aortic aneurysm or occlusive disease. Conventional treatments such as extra-anatomic bypass grafting with aortic ligation and subsequent graft removal with bowel repair are associated with a 25% to 90% operative mortality rate. In the emergency setting, patients unsuitable for major arterial surgery may benefit from a staged, less invasive approach.
View Article and Find Full Text PDF